MIC-5001, 5000V Insulation Tester

Availability:

5 in stock


Insulation resistance measurement in a compact, light-weight, low-cost design.

  • Measurement to 5 TΩ
  • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
  • Continuous indication of insulation resistance or leakage current
  • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
  • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
  • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
  • Continuous display of test voltage during the measurement
  • Protection against measuring live objects
  • Two and three-lead measurement method
  • Ramp Test Insulation resistance measurement
  • Measurement of breakdown voltage with increments up to 1 kV / s
  • Measurement of alternating and direct voltages from 0 V to 750 V
  • 990 cells of memory (11880 records) to record results
  • Data transfer to PC via USB cable
  • Built-in rechargeable battery pack
  • Meets the requirements of the EN 61557 standard
  • Charge from optional car lighter (12 V) socket accessory

0

5 in stock

Compare

Insulation Resistance Meter

Category:
Weight 1 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557- 2 for RISOmin=VISOnom/IISOmax…5 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(3% m.v. + 20 digits)
1.000 to 5.000 TΩ 1 GΩ ±(4% m.v. + 50 digits)

Values of measured resistance depending on measurement voltage

Voltage VISO Measurement range
up to 100 V 50 GΩ
200 to 400 V 100 GΩ
500 to 900 V 250 GΩ
1000 to 2400 V 500 GΩ
2500 V 2500 GΩ
5000 V 5 TΩ

RampTest Insulation resistance measurement

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(5% m.v. + 40 digits)
1.000 to 4.999 TΩ 0.001 TΩ ±(5% m.v. + 40 digits)

The measurement of breakdown voltage in RampTest mode

Range Resolution Chosen UISO Accuracy
25.0 V to 99.0 V 0.1 V <600 V ± 5% m.v. ± 10 digits
100 V to 600 V 1 V <600 V ± 5% m.v. ± 4 digits
25 V to 999 V 1 V >600 V ± 5% m.v. ± 5 digits
1.00 kV to 5.00 kV 10V >600 V ± 5% m.v. ± 4 digits

DC and AC voltage measurement

Range Resolution Accuracy
0 to 299.9 V 0.1 V ±(3% m.v. + 2 digits)
300 to 750 V 1 V ±(3% m.v. + 2 digits)
  • frequency range: 45 to 65 Hz

VISO – measurement voltage
The acronym “m.v.” stands for a “measured reference value”

Electrical safety:

  • type of insulation double, in acc. with EN 61010-1 and IEC 61557
  • measurement category III 600 V (IV 300 V) in acc. EN 61010-1
  • case protection rating in acc. EN 60529 IP6529: IP65

Other technical specifications::

  • power supply of the meter NiMH 9.6 V – 2 Ah battery pack and power supply 12 V
  • weight of the meter approx. 0.9 kg, 2 lbs
  • dimensions 200 x 180 x 77 mm, 7.9 x 7 x 3 ins
  • LCD segment display
  • memory for measurement results:  990 cells, 11880 records
  • transfer of measurement results data via USB

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-5001, 5000V Insulation Tester”

There are no reviews yet.

  • DC Power Supply UTP3305

    0 out of 5
    (0)

    Features:

    1. Dual channel, two circuits of adjustableoutput voltage 0~32V and one circuit of fixed voltage 5V.

    2. Master-slave tracking, constant voltageand current, Ⅰ, Ⅱ circuit can be used for master-slave tracking and used in parallelor in series.

    3. Forced ventilation, temperature controlcooling system. When the temperature reaches 65℃, the device dissipatesheat automatically.

    4. Display mode: LED digital tube display,can show voltage and current simultaneously.

    5. Low ripple, low noise

    6. High regulation: 0.01%

    7. Output ON/OFF control

    8. Constant voltage and constant currentoperation

    9. Optional European standard outputterminal

    10. Overload protection, reverse polarityprotection

    SKU: n/a
  • ET 8101 DMM

    0 out of 5
    (0)
    • Specifications: Brand Name: WinAPEX Color: Black Material: ABS Plastic Display: LCD Display with Backlight, 5999 counts(5 5/6) Range Control: Auto Range & Manual Range Screen Size: 48 * 30mm / 1.9 * 1.2in Operating Environment: IEC61010-1, CAT III 600V DC Voltage Range: 6V/60V/600V/1000V DC Voltage Resolution: 0.001V/0.01V/0.1V/1V AC Voltage Range: 6V/60V/600V/750V AC Voltage Resolution: 0.001V/0.01V/0.1V/1V DC Current Range: 600A/6000A/60mA/600mA/6A/10A DC Current
    • Resolution: 0.1A/1A/10A/100A/0.01A AC Current Range: 600A/6000A/60mA/600mA/6A/10A AC Current Resolution: 0.1A/1A/10A/100A/0.01A Frequency Range: 10Hz/100Hz/1KHz/10KHz/100KHz/1MHz/10MHz Frequency Resolution: 0.01Hz/0.1Hz/1Hz/10Hz/100Hz/1kHz/10kHz Resistance Range: 600/6k/60k/600k/6M/40M Resistance Resolution: 0.1/1/10/100/1k/10k Capacitance Range: 60nF/600nF/6F/60F/600F/6mF/30mF Capacitance Resolution: 10pF/100pF/1nF/10nF/100nF/11F/10F Duty Cycle: 0.1%~99% Duty Cycle
    • Resolution: 0.1% Function: DC/AC Voltage Current, Resistance, Capacitance, Data Hold, Max & Min Value Test, Backlight, Auto Power off, NCV Test, Continuity Buzzer Test with LCD, Over Load Protection, Short-circuit Protection, Live Fire Wire Identification, Frequency Test, Duty Cycle Measurement, Diode Test Sampling Time: about 3 times/second Working Temperature/Humidity: 0~40, <80% Storage Temperature/Humidity: -10~50, <70% Power Supply: 2 * 1.5V AAA Batteries
    • (Not Included) Item Size: 145 * 70 * 32mm / 5.7 * 2.8 * 1.3in Item Weight: 166g / 5.9oz
    SKU: n/a
  • UT343A Coating Thickness Gauge

    0 out of 5
    (0)

    Features of UT343A Coating Thickness Gauge

    Certificates: CE, UKCA

    ● Data storage: 199 groups
    ● Measurement method: Single/Continuous
    ● Max/Min/Avg
    ● Unit conversion (um/mil)

    ● Rotatable screen
    ● LED/Buzzer alarm
    ● Auto power off

    SKU: n/a
  • UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V) (Discontinued)

    0 out of 5
    (0)

    Features of UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V)

    Certifications: CE, RoHS, UL

    ● Complies with CAT IV 600V (UT13A); prevent damage caused by transient voltage
    ● CAT IV 1000V (UT13B)
    ● LED indication
    ● Vibration indication (UT13B)
    ● Adjustable sensitivity

    SKU: n/a
  • PQM-707 Power Quality Analyzer

    0 out of 5
    (0)
    • Features:

      • 7″ touch screen – intuitive operating
      • CAT IV 600V – high safety
      • all parameters acc. to class S – high accuracy of measurements
      • Li-Ion rechargeable battery – higher mobility
      • removable memory card – recording data with no restrictions

      Possible measurements:

      • Measurements according to EN 50160,
      • Voltage L1, L2, L3, N-PE (five inputs),
        – average, minimum, maximum values, range to 760 V, ability to work with voltage transformers,
      • Current L1, L2, L3, N (four inputs),
        – average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
      • Crest factor for voltage and current,
      • Frequency from 40 Hz to 70 Hz ,
      • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
      • Power recording:
        • Budeanu method,
        • IEEE 1459,
      • Active, reactive, apparent energy,
      • Power factor, cosφ, tgφ,
      • Up to 50th harmonics for voltage and current,
      • Total Harmonic Distortion (THD) for voltage and current,
      • Short-term (PST) and long-term (PLT) flicker,
      • Unbalance of voltage and current,
      • Current and voltage events registration including waveforms and RMS graphs half period,
      • Inrush current
      • Calculator of energy tariffs
      • ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
    SKU: n/a