MIC-5001, 5000V Insulation Tester

Availability:

5 in stock


Insulation resistance measurement in a compact, light-weight, low-cost design.

  • Measurement to 5 TΩ
  • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
  • Continuous indication of insulation resistance or leakage current
  • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
  • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
  • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
  • Continuous display of test voltage during the measurement
  • Protection against measuring live objects
  • Two and three-lead measurement method
  • Ramp Test Insulation resistance measurement
  • Measurement of breakdown voltage with increments up to 1 kV / s
  • Measurement of alternating and direct voltages from 0 V to 750 V
  • 990 cells of memory (11880 records) to record results
  • Data transfer to PC via USB cable
  • Built-in rechargeable battery pack
  • Meets the requirements of the EN 61557 standard
  • Charge from optional car lighter (12 V) socket accessory

0

5 in stock

Compare

Insulation Resistance Meter

Category:
Weight 1 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557- 2 for RISOmin=VISOnom/IISOmax…5 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(3% m.v. + 20 digits)
1.000 to 5.000 TΩ 1 GΩ ±(4% m.v. + 50 digits)

Values of measured resistance depending on measurement voltage

Voltage VISO Measurement range
up to 100 V 50 GΩ
200 to 400 V 100 GΩ
500 to 900 V 250 GΩ
1000 to 2400 V 500 GΩ
2500 V 2500 GΩ
5000 V 5 TΩ

RampTest Insulation resistance measurement

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(5% m.v. + 40 digits)
1.000 to 4.999 TΩ 0.001 TΩ ±(5% m.v. + 40 digits)

The measurement of breakdown voltage in RampTest mode

Range Resolution Chosen UISO Accuracy
25.0 V to 99.0 V 0.1 V <600 V ± 5% m.v. ± 10 digits
100 V to 600 V 1 V <600 V ± 5% m.v. ± 4 digits
25 V to 999 V 1 V >600 V ± 5% m.v. ± 5 digits
1.00 kV to 5.00 kV 10V >600 V ± 5% m.v. ± 4 digits

DC and AC voltage measurement

Range Resolution Accuracy
0 to 299.9 V 0.1 V ±(3% m.v. + 2 digits)
300 to 750 V 1 V ±(3% m.v. + 2 digits)
  • frequency range: 45 to 65 Hz

VISO – measurement voltage
The acronym “m.v.” stands for a “measured reference value”

Electrical safety:

  • type of insulation double, in acc. with EN 61010-1 and IEC 61557
  • measurement category III 600 V (IV 300 V) in acc. EN 61010-1
  • case protection rating in acc. EN 60529 IP6529: IP65

Other technical specifications::

  • power supply of the meter NiMH 9.6 V – 2 Ah battery pack and power supply 12 V
  • weight of the meter approx. 0.9 kg, 2 lbs
  • dimensions 200 x 180 x 77 mm, 7.9 x 7 x 3 ins
  • LCD segment display
  • memory for measurement results:  990 cells, 11880 records
  • transfer of measurement results data via USB

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-5001, 5000V Insulation Tester”

There are no reviews yet.

  • UT620A Digital Micro Ohm Meter

    0 out of 5
    (0)

    Features of UT620A Digital Micro Ohm Meter

    ● Comparison measurement with upper and lower limits
    ● Wire length measurement (m/ft)
    ● Built-in Lithium battery
    ● 1000-group data storage
    ● Improved measurement method which improves accuracy by counter-balancing contact resistance of leads
    ● Data transmission between USB and PC
    ● Data hold
    ● LCD backlight
    ● Zeroing function, relative mode
    ● IND resistance measurement mode
    SKU: n/a
  • YTH 109 PCB CUTTER

    0 out of 5
    (0)

    Suitable for cutting wire, electronic feet, trimming plastic products, cutting small metal wire, repairing of electronics industry, jewelry processing, model making and so on

    SKU: n/a
  • MECHANIC V4B48 SOLDER PPD PASTE

    0 out of 5
    (0)

    Battery Welding Pen MECHANIC W08 Multi-functional Mobile Power Circuit Detector Phone Repair Short Killer Electric Weld Machine

    SKU: n/a
  • RF4 Microscope RF-7050pro- FO19 360 degree Rotatable Mobile Repair Digital Trinocular Electronic Microscope For Cell Phone

    0 out of 5
    (0)

    RF4 Microscope RF-7050pro- FO19 360 degree Rotatable Mobile Repair Digital Trinocular Electronic Microscope For Cell Phone

    SKU: n/a
  • RF-6555TVP

    0 out of 5
    (0)
    SKU: n/a
  • CLAMP METER AC BM 528F

    0 out of 5
    (0)
    Product Description
    BM528F AC Digital Clamp meter Technical parameters
    Functions
    Range
    Accuracy

    (BM528F)
    DC Voltage
    200mV/2V/20V/200V/1000V
    ±(0.8%+2)
    AC Voltage
    2V/20V/200V/700V
    ±(1.2%+5)
    AC Current
    2A/20A/200A/600A
    ±(2%+10)
    Ω Resistance
    200/2K/20K/200K/2M/20MΩ
    ±(1%+3)
    Capacitance
    20n/200n/2μ/20μ/200μ/2mF
    ±(3%+5)
    Frequency
    200/2K/20K/200K/2M/20MHz
    ±(0.5%+3)
    ℃ / ℉
    -50℃ ~1000℃

    -58℉~1832℉

    ±(1%+5)

    ±(1.2%+6)