Product Features 1. 6000 Counts 2. True RMS voltage and current measurements 3. Capacitance, Resistance, Buzzer, Diode 4. Capacitance with REL function, resolution is 1pF, maximum measurement range is 6000μF 5. Highly accurate frequency measurement function; minimum resolution is 0.001Hz 6. MAX\MIN and MAX-MIN value 7. DC current minimum resolution is 0.01 A, AC current minimum resolution is 1μA, maximum range is 20A 8. HOLD function,backlight and auto power off function
UT890D Digital Multimeter
20 in stock
Product Features 1. 6000 Counts 2. True RMS voltage and current measurements 3. Capacitance, Resistance, Buzzer, Diode 4. Capacitance with REL function, resolution is 1pF, maximum measurement range is 6000μF 5. Highly accurate frequency measurement function; minimum resolution is 0.001Hz 6. MAX\MIN and MAX-MIN value 7. DC current minimum resolution is 0.01 A, AC current minimum resolution is 1μA, maximum range is 20A 8. HOLD function,backlight and auto power off function
₨4,560 ₨5,491
20 in stock
CompareWeight | 0.35 kg |
---|---|
Dimensions | 18 × 9 × 6 cm |
Specifications | Range | Accuracy |
DC current(V) | 600.0mV | ±(0.5%+4) |
6.000V/60.00V/600.0V | ±(0.5%+2) | |
1000V | ±(0.7%+10) | |
AC current(V) | 6.000V/60.00V/600.0V | ±(0.8%+3) |
750V | ±(1.0%+10) | |
AC Current(A) | 6.000mA/60.00mA | ±(1.0%+12) |
600.0mA | ±(2.0%+3) | |
20.00A | ±(3.0%+5) | |
DC Current(A) | 60.00μA/6.000mA/60.00mA | ±(0.8%+8) |
600.0mA | ±(1.2%+5) | |
20.00A | ±(2.0%+5) | |
Resistance(Ω) | 600.0Ω | ±(0.8%+5) |
6.000kΩ/60.00kΩ/600.0kΩ/6.000MΩ | ±(0.8%+3) | |
60.00MΩ | ±(1.0%+25) | |
Capacitance(F) | 9.999nF | ±(5.0%+35) |
99.99nF~999.9μF | ±(2.5%+20) | |
9.999mF | ±(5.0%+10) | |
99.99mF | 10mF≤C≤20mF | |
±(10.0%+5) | ||
Frequency(Hz) | 9.999Hz~9.999MHz | ±(0.1%+5) |
Measurement range: 10Hz~10MHz(Auto Range), ≤100kHz∶100mVrms≤Input amplitude≤30Vrms,>100kHz~1MHz∶200mVrms≤Input amplitude≤30Vrms,>1MHz∶600mVrms≤Input amplitude≤30Vrms | ||
MAX/MIN | √ | |
True RMS | √ | |
Frequency Response | Applies to sine wave and triangular wave, ≥200Hz, other waveforms are for reference | 40Hz~1kHz |
Diode Test | √ | |
hFE | √ | |
Continuity Test | √ | |
REL | √ | |
Data Hold | √ | |
Backlight Adjustment | √ | |
Battery Voltage Indicator | √ | |
Auto Power Off | Around 15 Minutes | √ |
Input Impedance For DCV | ≥10MΩ | √ |
General Characteristics | ||
Use Environment | 18℃~28℃(64℉~82℉) Relative Temperature | |
Battery | 9V Battery(6F22) | |
LCD size | 63mm × 29mm | |
Product Color | Red and Grey | |
Product Net Weight | 300g | |
Product Size | 186mm × 91mm × 39mm | |
Standard Accessories | Test Leads, Battery | |
Standard Individual Packing | Gift Box, Instructions, Warranty Card | |
Standard Quantity Per Carton | 40PC | |
Standard Individual Packing Size | 645mm × 450mm × 340mm | |
Standard Carton Gross Weight | 22.8 Kg |
Based on 0 reviews
Be the first to review “UT890D Digital Multimeter”
-
Digital Multi Meter
UNI-T UTL8212 High-Precision Compact DC Electronic Load Tester Single/Dual Channel 150V Power Supply Current Test – UTL821
Digital Multi MeterUNI-T UTL8212 High-Precision Compact DC Electronic Load Tester Single/Dual Channel 150V Power Supply Current Test – UTL821
Power supply test, adapter/charger test, battery test, lithium battery protection board test, ATE, component test, etc., commonly used in home appliance manufacturers, LCD and other computer component manufacturers, switching power supply and LED manufacturers, adapter charger manufacturers and other companies Production and testing use
SKU: n/a -
Oscilloscopes
UNI-T MSO3154E 150MHz Mixed Signal 4 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
Multimeters, Phase Detector Meters
UT261B Phase Sequence and Motor Rotation Indicator
UT261 series is used for determining 3-phase power phase sequence, missing phase indication, and motor phase rotation (UT261B). UT261A and UT261B can measure AC voltage of 40~700V and 90~600V respectively. These devices can operate in frequency range of 15~400Hz. UT261 are durable devices which can withstand impact from 2 meter’ s height. Test leads with protective tubing are included in optional accessories.
SKU: n/a -
Oscilloscopes
UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
Oscilloscopes
UNI-T MSO3254E 250MHz Mixed Signal 4 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a
There are no reviews yet.