-17%

UT890D Digital Multimeter

Availability:

20 in stock


Product Features
16000 Counts
2True RMS voltage and current measurements
3Capacitance, Resistance, Buzzer, Diode
4Capacitance with REL function, resolution is 1pF, maximum measurement range is 6000μF
5Highly accurate frequency measurement function; minimum resolution is 0.001Hz
6MAX\MIN and MAX-MIN value
7DC current minimum resolution is 0.01 A, AC current minimum resolution is 1μA, maximum range is 20A
8HOLD function,backlight and auto power off function

4,560 5,491

20 in stock

Compare
Product Features
16000 Counts
2True RMS voltage and current measurements
3Capacitance, Resistance, Buzzer, Diode
4Capacitance with REL function, resolution is 1pF, maximum measurement range is 6000μF
5Highly accurate frequency measurement function; minimum resolution is 0.001Hz
6MAX\MIN and MAX-MIN value
7DC current minimum resolution is 0.01 A, AC current minimum resolution is 1μA, maximum range is 20A
8HOLD function,backlight and auto power off function
Category:
Weight 0.35 kg
Dimensions 18 × 9 × 6 cm
Specifications Range Accuracy
DC current(V) 600.0mV ±(0.5%+4)
6.000V/60.00V/600.0V ±(0.5%+2)
1000V ±(0.7%+10)
AC current(V) 6.000V/60.00V/600.0V ±(0.8%+3)
750V ±(1.0%+10)
AC Current(A) 6.000mA/60.00mA ±(1.0%+12)
600.0mA ±(2.0%+3)
20.00A ±(3.0%+5)
DC Current(A) 60.00μA/6.000mA/60.00mA ±(0.8%+8)
600.0mA ±(1.2%+5)
20.00A ±(2.0%+5)
Resistance(Ω) 600.0Ω ±(0.8%+5)
6.000kΩ/60.00kΩ/600.0kΩ/6.000MΩ ±(0.8%+3)
60.00MΩ ±(1.0%+25)
Capacitance(F) 9.999nF ±(5.0%+35)
99.99nF~999.9μF ±(2.5%+20)
9.999mF ±(5.0%+10)
99.99mF 10mF≤C≤20mF
±(10.0%+5)
Frequency(Hz) 9.999Hz~9.999MHz ±(0.1%+5)
Measurement range: 10Hz~10MHz(Auto Range), ≤100kHz∶100mVrms≤Input amplitude≤30Vrms,>100kHz~1MHz∶200mVrms≤Input amplitude≤30Vrms,>1MHz∶600mVrms≤Input amplitude≤30Vrms
MAX/MIN
True RMS
Frequency Response Applies to sine wave and triangular wave, ≥200Hz, other waveforms are for reference 40Hz~1kHz
Diode Test
hFE
Continuity Test
REL
Data Hold
Backlight Adjustment
Battery Voltage Indicator
Auto Power Off Around 15    Minutes
Input Impedance For DCV ≥10MΩ
General Characteristics
Use Environment 18℃~28℃(64℉~82℉) Relative Temperature
Battery 9V Battery(6F22)
LCD size 63mm × 29mm
Product Color Red and Grey
Product Net Weight 300g
Product Size 186mm × 91mm × 39mm
Standard Accessories Test Leads, Battery
Standard Individual Packing Gift Box, Instructions,    Warranty Card
Standard Quantity Per Carton 40PC
Standard Individual Packing Size 645mm × 450mm × 340mm
Standard Carton Gross Weight 22.8 Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT890D Digital Multimeter”

There are no reviews yet.

  • TDGC 500VA

    0 out of 5
    (0)

    Input Voltage=220V/230V
    Output Voltage=0-250V
    Maximum Output Current=2
    Copper Wind
    LCD Output Display

    SKU: n/a
  • AC/DC DIGITAL CLAMP METER KEW 2056R

    0 out of 5
    (0)

    • Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
    • CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
    • Very useful for power distribution companies, power utilities and maintenance fields.
    • True RMS enables an accurate measurement.

    SKU: n/a
  • UT521 Earth Groud Testers

    0 out of 5
    (0)

    UT520 series earth resistance tester hasthe functions of backlight display, low battery display, data hold, datastorage, auto power off and power saving. It can not only be used for accurate three-wiremeasurement but also simple two-wire measurement.

    It is applicable to measuring the earthresistance of all kinds of electrical power system, electrical equipment and anti-thunderequipment. It can also measure the earth voltage. It is applicable to testingoperating earth systems of smelting, communication, manufacture, fossil oil,national defense, electricity, chemical industry and construction.

    SKU: n/a
  • UT258A AC/DC Leakage Clamp Meter

    0 out of 5
    (0)

    UT258A is well designed for on-line measurement of DC/AC leakage current and current below 600V, which adopts latest CT and digital integration technology. Slender clamp is very suitable for places full of concentrated cables (such as, electric power metering system, high-speed rail system, automobile circuit maintenance and so on). Non-contact measurement ensures operation safety. The meter has mini shape with high accuracy, stable performance and perfect functions.

    SKU: n/a
  • UNI-T UTL8211/UTL8212 High-Precision Compact DC Electronic Load Tester Single/Dual Channel 150V Power Supply Current Test – UTL8211

    0 out of 5
    (0)

    Application:

     

    Power supply test, adapter/charger test, battery test, lithium battery protection board test, ATE, component test, etc., commonly used in home appliance manufacturers, LCD and other computer component manufacturers, switching power supply and LED manufacturers, adapter charger manufacturers and other companies Production and testing use

    SKU: n/a