TDR-410 Cable Fault Locator

Availability:

Out of stock


  • Features:

    • automatic or manual mode:
      • the automatic fault location (AFL),
      • mode with manual range selection and sensitivity,
      • single measurement triggered manually or scanning continuous,
    • 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
    • maximum length of cable up to 4000 m one end of the cable,
    • “Dead zone” measure limited to 0.5 m,
    • 2.5 “LCD screen with backlight,
    • scan automatically or manually trigger,
    • sensitivity set manually or automatically adjusted,
    • adjustable impedance matching,
    • propagation coefficient adjustment 1% to 99%,
    • waterproof and resistant to mechanical housing.
    • small size and weight.
    • economical power system – 30 hours of continuously scan on one battery set..

    Accessories:

    • 0,6 m double-wire lead: WAPRZ0X6DZBB
    • red crocodile clip: WAKRORE20K02
    • Krokodylek czarny: WAKROBL20K01
    • cover M-2: WAFUTM2

0

Out of stock

Compare
  • Location damaged power cables.
  • Fault location copper telecom cables.
  • Coaxial cable fault location.
  • Fault location wiring infrastructure.
  • Detection of breaks, short circuits, damage caused by dampness and other changes in impedance of the cable.
  • Graphic depiction of damage the cable with automatic indication the distance to fault on the screen.

Dechnical data:

  • Ranges Meters: 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km
  • Ranges Feet: 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 14000.
  • Range Selection: Manual range control / Auto range.
  • Accuracy: 1% of selected range*.
  • Resolution: Approx 1% of range.
  • Minimum cable lenght: 4m (14ft).
  • Sensitivity: Min 3 pixel return at 4km on 0.6mm Ø, PE, TP.
  • Velocity Factor: Adjustable from 1% to 99%.
  • Output Pulse: 5 volts peak to peak into open circuit.
  • Output Impedance: Selectable 25, 50, 75 & 100 Ω.
  • Output Pulse: Width 3 ns to 3 µs, Automatic with range.
  • Scan Rate: 2 scans/second or scan held, pre set for each range scale.
  • Tone Generator: 810 – 1100Hz.
  • Battery Life: 30 hours continuous scanning.
  • Power Supply: 6 volts 4 x 1.5 AA Alkaline cells, on-screen low voltage indicator.
  • Power Down Selectable: 1, 2, 3, 5 minutes or disabled.
  • Back Lit Display: 128 x 64 pixel.
  • Voltage Protection: 250 volts AC.
  • Operating Temp: -10º / 50ºC.
  • Storage Temp: -20º +70° C.
  • Dimensions: 165 x 90 x 37 mm (6.5 x 3.5 x 1.5 ins).
  • Weight: 350 g (12oz).
  • Safety: IEC 61010-1, EN 60950.
  • EMC: BS/EN 61326-1.
  • Water/Dust Proof: IP54

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “TDR-410 Cable Fault Locator”

There are no reviews yet.

  • UT195DS Professional Digital Multimeters

    0 out of 5
    (0)

    1. IP65 rating, 2m drop proof, CAT III 1000V, CAT IV 600V

    2. Large 6000-count LCD screen

    3. 5/s sampling rate

    4. True RMS

    5. ACV 750V 5kHz bandwidth

    6. (AC+DC) or (AV+FREQ) , dual mode

    7. Flashlight

    8. Auto LCD backlight controlled by light sensor (can be turned off)

    9. LoZ voltage test, for ghost voltage measurement

    10. Motor phase sequence measurement with 2 probes

    11. 20A current measurement (max 30 seconds)

    12. 31 analogue bar

    13. Low pass filter, 1kHz 3dB attenuation

    SKU: n/a
  • UTD2102CEX-II Digital Storage Oscilloscope

    0 out of 5
    (0)

    1. 2 channels

    2. 70MHz/100MHz bandwidth; 1GSa/s real-time sampling rate
    3. Up to 28Mpts memory depth
    4. Calibration signal output: 10Hz, 100Hz, 1kHz (by default),
    10kHz or 100kHz
    5. Max 10Mpts waveform record
    6. 8-inch TFT LCD, WVGA (800X480)
    SKU: n/a
  • UT206A+

    0 out of 5
    (0)

    1. 1000A AC current measurement
    2. 1000V AC/DC voltage measurement
    3. 600A inrush current measurement (UT206A+)
    4. Temperature (UT206A+)
    5. NCV (UT206A+)
    6. ACV frequency 10Hz~10kHz
    7. Jaw opening: 45mm
    8. Resistance / capacitance / frequency measurement
    9. Auto range / backlight / low battery indication
    10. Continuity / diode / duty cycle
    11. MAX/MIN
    12. Data hold / flashlight / relative mode
    13. Auto power off
    14. CAT II 1000V/CAT III 600V

    SKU: n/a
  • UT81C Scope Digital Multimeter

    0 out of 5
    (0)

    UT81 series handheld digital oscilloscope multimeters combine oscilloscope and digital multimeter in one. Oscilloscope measurement mode includes signal input, data processing, auto measure, waveform storage, and transfer.

    Multimeter mode features AC/DC voltage and current, resistance, diode, continuity, frequency, duty ratio, and capacitance
    SKU: n/a
  • UT890D Digital Multimeter

    0 out of 5
    (0)
    Product Features
    16000 Counts
    2True RMS voltage and current measurements
    3Capacitance, Resistance, Buzzer, Diode
    4Capacitance with REL function, resolution is 1pF, maximum measurement range is 6000μF
    5Highly accurate frequency measurement function; minimum resolution is 0.001Hz
    6MAX\MIN and MAX-MIN value
    7DC current minimum resolution is 0.01 A, AC current minimum resolution is 1μA, maximum range is 20A
    8HOLD function,backlight and auto power off function
    SKU: n/a
  • RF-6565TV

    0 out of 5
    (0)
    SKU: n/a