-11%

A37 CO2 Meter


Main Features

1. Automatic baseline correction

2. Audible and visual alarm

3. Low battery indication

4. Auto power off

5. Backlight

30,000 33,544

Compare

Main Features

1. Automatic baseline correction

2. Audible and visual alarm

3. Low battery indication

4. Auto power off

5. Backlight

Category:
Specifications Range Resolution Precision
Model A37
Carbon dioxide 400ppm~5000ppm 1ppm ±5%rdg + 50ppm from 400ppm~2000ppm (at ambient temperature and humidity)
Temperature  -10.0℃~50.0℃ 0.1℃ Typical accuracy: ±1℃
Relative humidity  0%RH~99%RH 1%RH Typical accuracy: ±5%RH (10%RH~90%RH) at 25℃
Features
ABC Automatic baseline correction
Audible and visual alarm
Sensor type NDIR (no-dispersive infra) CO2 sensor
Response time T90 < 2 minutes
Date/time Display the date and time
Low power display low power symbol keep flashing
Auto power off auto power off if no opeartion for long time
Backlight The white backlight can be turned on/off.
It will be automatically turned off after 20-minute inactivity.
Operating temperature 0℃~50℃, 0%RH~85%RH
Storage temperature -20℃~60℃, 0%RH~95%RH
General Characteristics 
Power 3.7V DC Li-ion battery/ Micro USB charging port
LCD size 42 x 65mm
Product color White
Product net weight about 195g
Product size 75 x 55 x 130mm
Standard accessory Micro USB charging cable
Standard individual packing Gift box, English manual

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “A37 CO2 Meter”

There are no reviews yet.

  • UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • MRU-30 Earth Resistance and Resistivity Meter

    0 out of 5
    (0)

     

    • It allows to take the measurements of:

      • earthing resistance using auxiliary electrodes,
      • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
      • earthing resistance using double clamps for measuring multiple earthing without underground connections.
      • ground resistivity (Wenner method),
      • continuity of equipotential bondings and protective
      • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

      Additionally:

      • measurement of resistance of auxiliary electrodes RS and RH,
      • measurement of interference voltage,
      • measurement in the presence of interference voltage in the power network
      • with frequency 50Hz, 60Hz,
      • selection of maximum measuring voltage (25V and 50V),
      • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
      • memory of 990 measurements (10 banks of 99 cells each),
      • calibration of clamp used,
      • data transmission to the computer (USB),
      • indication of battery state.
    SKU: n/a
  • UT243 Power and Harmonics Clamp Meters

    0 out of 5
    (0)

    UT240 series is a stable, safe and reliable handheld power and harmonics clamp meter, which combines with digital ammeter, power measurement, harmonic measurement and equipped with a powerful measurement and data processing software. It is suitable for testing, calculating and displaying voltage, current, active power, power factor, phase angle, apparent power, reactive power, harmonic, electrical energy and frequency etc. Its harmonic measurement can be measured up to 20 times.

    SKU: n/a
  • TDGC 5000VA

    0 out of 5
    (0)

    Input Voltage=220V/230V
    Output Voltage=0-250V
    Maximum Output Current=20
    Copper Wind
    LCD Output Display

    SKU: n/a
  • YH IRON FOR 948D

    0 out of 5
    (0)
    SKU: n/a