UT312 Vibration Tester
UT310 series handheld vibration testers can measure displacement, velocity, and acceleration of rotating and reciprocating machinery. Technicians can use these to monitor equipment status and ensure normal operation.
10 in stock
1. Highly accurate and precise
₨85,000 ₨97,000
10 in stock
CompareUT310 series handheld vibration testers can measure displacement, velocity, and acceleration of rotating and reciprocating machinery. Technicians can use these to monitor equipment status and ensure normal operation.
Weight | 0.2 kg |
---|---|
Dimensions | 18 × 7 × 3 cm |
Specifications | Range | UT312 |
Acceleration (O-P) | 0.1~199.9m/s² | Frequency response: 10~1500Hz, Amplitude error: ≤±5% |
Amplitude linear error: ≤2.0m/s², ≤±10%; >2.0m/s², ≤±5% | ||
Velocity (RMS) | 0.1~199.9mm/s | Frequency response: 10~1500Hz, Amplitude error: ≤±5% |
Amplitude linear error: ≤2.0m/s, ≤±10%; >2.0m/s, ≤±5% | ||
Displacement (P-P) | 1~1999μm | Frequency response: 10~500Hz, Amplitude error: ≤±5% |
Amplitude linear error: ≤20um, ≤±10%; >20um, ≤±5% | ||
Features | ||
Data hold | √(auto data hold when releasing the measure key) | |
Low battery indication | √ | |
Auto power off | √(auto power off 1 minute after releasing the measure key) | |
Battery life | Continuous measuring time > 20 hours | |
Display count | 2000 | |
General Characterisitics | ||
Power | 9V battery (6F22 ) | |
Product color | Red and grey | |
Product net weight | 230g (including battery) | |
Product size | 185mm x 68mm x 30mm | |
Standard accessories | Battery, tool box | |
Standard individual packing | Gift box, English manual | |
Standard quantity per carton | 5pcs | |
Standard carton measurement | 375mm x 307mm x 246mm | |
Standard carton gross weight | 5.8kg |
UT510 series is a kind of intelligent insulation tester. The device circuit design takes microcomputer technology design as the core and combines the large scale integrated circuit with digit circuit. It is equipped with strong measuring software and data processing software. It is applied to the parameter measurement of insulation resistance, voltage and low resistance. It has stable performance and simple operation. It is applicable to on-site measurement and repair of the electrical equipment and charging line. It is the ideal tool of maintaining electrical equipment. It is also used for smelting, communication, manufacture, fossil oil, national defense, electricity, chemical industry and circuit.
It provides:
Main Features
1. 10A/400A AC/DC measurement with Hall-effect sensor
2. Auto range makes measurement faster and more effective
3. 4000 display count, 3/s sampling rate
4. True RMS measurement
5. NCV, Non-Contact AC Voltage testing
6. Frequency and duty ratio measurement
7. MAX/MIN mode
8. Relative mode
9. Flashlight function for measuring at night or in the dark
10. K-type point contact temperature probe for temperature measurement
11. Large jaw of 30mm
12. Data hold
13. LCD backlight
14. Auto power off
15. 1m drop proof
16. Complies with CE (European Union) directives
Analog bandwidth | 150MHz | 250MHz | ||
Channels | 2+16 digital | 4+16 digital | 2+16 digital | 4+ 16digital |
Sampling rate (Analog) | 2.5GS/s (Single channel), 1.25GS/s (Dual channels) | |||
Sampling rate (Digital) | 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) | |||
Memory depth | 70Mpts | |||
Waveform capture rate | 200,000wfms/s | |||
Time base scale | 2ns/div~50s/div (Real-time sampling rate, memory depth display ) | |||
Time base scale (digital) | 2ns/div~40S/div[Step by 1-2-4 stall] | |||
Input impedance | (1MΩ±1%) II (20pF±3pF) | |||
Input impedance digital | (101kΩ±1%) II (9pF±1pF) | |||
Vertical scale | 1mV/div~20 V/div (1 MΩ) | |||
DC gain accuracy | <5mV: ±3%, ≥5mV: ±2% | |||
Waveform record | 100,000 frames | |||
Trigger types | Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay |
|||
Bus decode | RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay | |||
Waveform operations | A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations | |||
Auto measurements |
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width, -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A |
|||
Measurement display | 5 types | |||
Measurement statistics | Average, Max, Min, standard deviation and number of measurements | |||
Frequency counter | 6 bits | |||
Standard interfaces | USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA | |||
Standard Accessories |
USB interface cable | UT-D14 | ||
Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) | UT-P06 | |||
Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) | UT-P05 | |||
16CH Logic analyzer probe | UT-15M |