Wire & Cable Testers
UT18D Voltage and Continuity Tester
Availability:
10 in stock
1. Auto power off, the conductor to be measured is greater than 12V
2. Phase rotation test
3. Continuity test with buzzer and LED indication
4. Low battery indication and over voltage prompt
5. Flashlight
6. Test live voltage without batteries
7. Buzzer and silent modes available
8. Auto range
9. Polarity indication
₨12,000 ₨13,000
10 in stock
CompareUT18 series are designed for testing AC/DC voltage, 3-phase voltage, phase sequence, continuity, and more. This series is categorized as CAT IV 600V and meets IP65 standard. These voltage testers are perfect tools for electricians to quickly measure voltage levels in all environments. This series should NOT be used with 110V electrical systems.
Weight | 0.3 kg |
---|---|
Dimensions | 27 × 8 × 3 cm |
Based on 0 reviews
Be the first to review “UT18D Voltage and Continuity Tester”
-
Laser Distance Meters
LM 570LD-I Laser Level Meter
Laser Type 1V1H Expanded Angle H110°/V110° Laser Class 2 Light Source 10 mW Laser Wavelength 510 nm H/V Accuracy ±3 mm/10 m Self-leveling Range 3°±1° Self-leveling Time 3 s Working Distance 20 m-40 m Operating Time >4 h Power AA battery (LR6) × 2 pcs. Operating Temperature from -10°C to +40°C Storage Temperature from -20°C to +70°C Dimensions 59 mm × 28 mm × 137 mm Weight 170 g SKU: n/a -
Rework & Soldering Station
YH 992D A+ 3 IN 1 REWORK STATION
parameters Rated voltage AC 220V±10% 50Hz power 720W±10%(Max) 300℃ Constant Temperature Power (High-Speed PID Programmed to Energy Savings) 250W±10% Working environment 0~40℃ relative humidity<80% Storage environment -20~80℃ relative humidity<80% Dimensions 255*188*125mm Weight 5.11KG Parts parameters Hot air gun Soldering iron Operating Voltage AC 220V±10% 50Hz AC 26V±10% 50Hz Output power 550W 75W Temperature range 100℃~480℃ 200℃~480℃ Air Supply Mode Diaphragm pump — Air Flow 28L/min(MAX) — Temperature Stability ±1℃ (Static) ±1℃ (Static) Display Mode LCD display LCD display Calibration Mode The PID digital program proofreading
The PID digital program proofreading
PID Temperature Calibration Cycle rapidly 20ms high-speed 100ms Heating Core Ceramic columned heating element. Imported heater Standard nozzles/tips (3mm,5mm,8mm,10mm,13mm) 5PCS nozzles
B Tip ground impedance — <2Ω Tip of ground voltage — <2mV SKU: n/a -
Clamp Meters
UT 205E 1000A True RMS Digital Clamp Meter
Specifications Range UT205E AC current (A) 1000A ±(2%+5) AC current frequency response 50Hz~60Hz AC voltage (V) 6V ±(1.2%+3) 60V/600V/1000V ±(1%+8) DC voltage (V) 600mV ±(0.8%+3) 6V/60V ±(0.5%+5) 600V ±(0.5%+5) 1000V ±(0.5%+5) AC voltage frequency response 40Hz~400Hz Resistance (Ω) 600Ω ±(1%+3) 6KΩ/60KΩ/600KΩ ±(1%+2) 6MΩ/60MΩ ±(2%+8) Capacitance (F) 60nF ±(4%+25) 600nF/6μF/60μF/600μF ±(4%+5) 6mF/60mF ±(10%+9) Low voltage frequency (Hz) 10Hz~1MHz ±(0.1%+3) Duty cycle (%) 10%~90% ±(2.6%+7) Features Display count 6000 Jaw opening 42mm Current frequency 50Hz~60Hz High voltage frequency 40Hz~400Hz Auto power off √ Continuity test √ Auto/Manual range √ Low battery indication √ Diode test √ Relative mode/Data hold √ MAX/MIN √ Function selection √ Flashlight √ Wake-up function √ Auto power off current: <50μA √ Input impedance (ACV/DCV) ≥10MΩ √ General Characteristics Power 1.5V battery (R03) x 3 Display 43mm x 45mm Product color Red and grey Product net weight 465g Product size 272mm x 81mm x 43.5mm Standard accessories Test leads, batteries, point contact temperature probe Standard individual packing Gift box, carrying bag, English manual Standard quantity per carton 10pcs Standard carton measurement 355mm x 330mm x 315mm Standard carton gross weight About 7.1kg SKU: n/a -
Clamp Meters
UT 206B Digital Clamp Meter
Specifications Range UT206B AC current (A) 1000A ±(2%+5) AC current frequency response 50Hz~60Hz Inrush current (A) 1000A ±(10%+10) AC voltage (V) 6V ±(1.2%+3) 60V/600V/1000V ±(1%+8) DC voltage (V) 600mV ±(0.8%+3) 6V/60V ±(0.5%+5) 600V ±(0.5%+5) 1000V ±(0.5%+5) Low pas filter (LPF ACV) 600V/1000V ±(2%+5) AC voltage frequency response 40Hz~400Hz LoZ ACV 600V/1000V ±(2%+5) Resistance (Ω) 600Ω ±(1%+3) 6KΩ/60KΩ/600KΩ ±(1%+2) 6MΩ/60MΩ ±(2%+8) Capacitance (F) 60nF ±(4%+25) 600nF/6μF/60μF/600μF ±(4%+5) 6mF/60mF ±(10%+9) Temperature (℃) -40℃~300℃ ±(1%+20) 300℃~1000℃ ±(1%+2) Low voltage frequency (Hz) 10Hz~1MHz ±(0.1%+3) Duty cycle (%) 10%~90% ±(2.6%+7) Features Display count 6000 Jaw opening 42mm Current frequency 50Hz~60Hz High voltage frequency 40Hz~400Hz Analog bar 31 Auto power off √ Continuity test √ Auto/Manual range √ Low battery indication √ Diode test √ Relative mode/Data hold √ MAX/MIN √ Function selection √ Flashlight √ Wake-up function √ Auto power off current: <50μA √ Flexible current probe (optional) Extends to 3000A √ Input impedance (ACV/DCV) ≥10MΩ √ General Characteristics Power 1.5V battery (R03) x 3 Display 43mm x 45mm Product color Red and grey Product net weight 465g Product size 272mm x 81mm x 43.5mm Standard accessories Test leads, batteries, point contact temperature probe Standard individual packing Gift box, carrying bag, English manual Standard quantity per carton 10pcs Standard carton measurement 355mm x 330mm x 315mm Standard carton gross weight About 7.1kg SKU: n/a
There are no reviews yet.