Main Features

1. 10A/400A AC/DC measurement with Hall-effect sensor

2. Auto range makes measurement faster and more effective

3. 4000 display count, 3/s sampling rate

4. True RMS measurement

5. NCV, Non-Contact AC Voltage testing

6. Frequency and duty ratio measurement

7. MAX/MIN mode

8. Relative mode

9. Flashlight function for measuring at night or in the dark

10. K-type point contact temperature probe for temperature measurement

11. Large jaw of 30mm

12. Data hold

13. LCD backlight

14. Auto power off

15. 1m drop proof

16. Complies with CE (European Union) directives

15,600 17,440

20 in stock

Compare

Main Features

1. 10A/400A AC/DC measurement with Hall-effect sensor

2. Auto range makes measurement faster and more effective

3. 4000 display count, 3/s sampling rate

4. True RMS measurement

5. NCV, Non-Contact AC Voltage testing

6. Frequency and duty ratio measurement

7. MAX/MIN mode

8. Relative mode

9. Flashlight function for measuring at night or in the dark

10. K-type point contact temperature probe for temperature measurement

11. Large jaw of 30mm

12. Data hold

13. LCD backlight

14. Auto power off

15. 1m drop proof

16. Complies with CE (European Union) directives

Category:
Weight 0.23 kg
Dimensions 22 × 7 × 4 cm
Specifications Range Best Accuracy
Model UT213C
AC Current (A) 40A/400A ±(2.5%+5)
DC Current (A) 40A/400A ±(2.0%+3)
AC Voltage (V) 4V/40V/400V/600V ±(1.2%+5)
DC Voltage (V) 400mV/4V/40V/400V/600V ±(0.8%+1)
Resistance (Ω) 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ ±(1.0%+2)
Capacitance (F) 40nF400nF/4μF/40μF/400μF/4mF/40mF ±(4.0%+5)
Frequency (Hz) 10Hz-1MHz ±(0.1%+4)
Temperature (°C) -40 °C ~ 1000°C ±(1.0%+3)
Temperature (°F) -40℉ ~  1832℉ ±(1.0%+6)
Features
Display Count 4000
Auto Range
Jaw Capacity 30mm
True RMS
Diode √(Around 3.0V)
NCV
Data Hold
Relative Mode
MAX/MIN
LCD Backlight
Flashlight
Auto Power Off
Continuity Buzzer
Low Battery Indication ≤3.6V
Input Protection
Input Impedance for DCV ≥10MΩ
General Characteristic 
Power AAA 1.5V × 3
LCD Size 38mm × 24 mm
Product Color Red and Grey
Product Net Weight 231.7g
Product Size 220mm ×  75mm ×  40mm
Standard Accessories Batteries, Test Lead,Point Contact Temperature Probe
Standard Individual Packing Gift Box, Carrying Bag, English Manual
Standard Quantity Per Carton 40 PCs
Standard Carton Measurement 485mm × 320mm × 385mm (0.060 CBM Per Standard Carton)
Standard Carton Gross Weight 20Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT213C ACA DCA Digital Clamp Meters”

There are no reviews yet.

  • UT89XD Digital Multimeter

    0 out of 5
    (0)

    1. 1000V AC/DC; 20A AC/DC

    2. True RMS, 6000 count
    3. Dual range NCV test which quickly identifies neutral and live wires
    through light intensity
    4. LED measurement
    5. Audible/visual alarm
    6. Capacitor charging indicator
    7. Ergonomic design
    8. Double injection molding
    9. 1m drop proof
    10. Flashlight; Auto backlight
    SKU: n/a
  • VC 9205A DMM

    0 out of 5
    (0)

    Feature:

     

    • Maximum voltage between terminals and earth ground: 1000DC or 700VAC
    • Fuse proteciton: F 200mA/250V
    • Power: 9V battery, NEDA 1604 0r 6F22
    • Display: LED
    • Operating temperature: 0~40℃
    • Storage temperature: -10~50℃
    • AC Voltage (V): 200mV, 2V, 20V, 200V, 700V
    • DC Voltage (V): 200mV, 2V, 20V, 200V,1000V
    • AC Current (A): 2mA, 20mA, 200mA, 20A
    • DC Current (A): 2mA, 20mA, 200mA, 20A
    SKU: n/a
  • ,

    JM-CT4-12 Electrician Wire Stripping Tool

    (1)

     

    Features:

    • Standard specs, form-ground, knife-type blades for accuracy, easy stripping without nicking insulation.
    • Built-in wire cutter and looping holes.
    • Convenient plier nose and sharp edge for pulling out the wire easily without damaging the wire cores.
    • Spring-loaded automatic opening
    • Sharp serrated edges in a plier style for wire pulls and loops.
    SKU: n/a
  • MRU-30 Earth Resistance and Resistivity Meter

    0 out of 5
    (0)

     

    • It allows to take the measurements of:

      • earthing resistance using auxiliary electrodes,
      • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
      • earthing resistance using double clamps for measuring multiple earthing without underground connections.
      • ground resistivity (Wenner method),
      • continuity of equipotential bondings and protective
      • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

      Additionally:

      • measurement of resistance of auxiliary electrodes RS and RH,
      • measurement of interference voltage,
      • measurement in the presence of interference voltage in the power network
      • with frequency 50Hz, 60Hz,
      • selection of maximum measuring voltage (25V and 50V),
      • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
      • memory of 990 measurements (10 banks of 99 cells each),
      • calibration of clamp used,
      • data transmission to the computer (USB),
      • indication of battery state.
    SKU: n/a
  • UT60EU

    0 out of 5
    (0)

    Product size
    Standard individual packing
    Product net weight
    Batery
    Product color
    1.5V AAA x 3
    Red and gray
    290g
    169 x 81 x 46mm
    420 x 320 x 300mm

    AC voltage (V)
    DC current (A)
    AC current (A)
    Resistance (Ω)
    Capacitor (F)
    Frequency (Hz)
    Duty cycle (%)
    Temperatue (°C/°F)
    Bluetooth
    Display count
    Auto range
    REL
    NCV
    Diode

    SKU: n/a