UT240 series is a stable, safe and reliable handheld power and harmonics clamp meter, which combines with digital ammeter, power measurement, harmonic measurement and equipped with a powerful measurement and data processing software. It is suitable for testing, calculating and displaying voltage, current, active power, power factor, phase angle, apparent power, reactive power, harmonic, electrical energy and frequency etc. Its harmonic measurement can be measured up to 20 times.
UT243 Power and Harmonics Clamp Meters
UT240 series is a stable, safe and reliable handheld power and harmonics clamp meter, which combines with digital ammeter, power measurement, harmonic measurement and equipped with a powerful measurement and data processing software. It is suitable for testing, calculating and displaying voltage, current, active power, power factor, phase angle, apparent power, reactive power, harmonic, electrical energy and frequency etc. Its harmonic measurement can be measured up to 20 times.
₨64,800 ₨66,136
Weight | 0.6 kg |
---|---|
Dimensions | 30 × 11 × 4 cm |
Specifications | Range | Best Accuracy |
Model | UT243 | |
AC Current (A) | 50A/250A/1000A | ±(2%+5) |
AC Voltage (V) | 150V/300V/600V | ±(1.2%+5) |
Frequency (Hz) | 50Hz~60Hz | √ |
Active Power (W) | 0.01KW~600KW | ±(3%+5) |
Apparent Power (VA) | 0.01KVAr~600KVAr | ±(4%+5) |
Reactive Power (VAr) | 0.01KVA~600KVA | ±(3%+5) |
Power Factor | 0.3~1 | ±(1%+2) |
Phase Angle (°) | 0° ~ 360° | ±1° |
Active Energy (Wh) | 1~9999KWh | ±(3%+5) |
Features | ||
Display Count | 10000 | |
Auto Range | √ | |
Jaw Capacity | 50mm | |
True RMS | √ | |
Auto Power Off | √ | |
Low Battery Indication | √ | |
Data Hold | √ | |
MAX/MIN | √ | |
Data Logging | 999 | |
USB Interface | √ | |
LCD Backlight | √ | |
Full Icon Display | √ | |
Single-Phrase 2-Wires | √ | |
3-Phrase 3-Wires | √ | |
3-Phrase 4-Wires | √ | |
Phase Sequence Test | √ | |
Harmonic Analysis | 1~20 | |
Setup | √ | |
Input Protection | √ | |
Input Impedance for DCV | Around 5MΩ | √ |
General Characteristic | ||
Power | 1.5V Batteries(LR6)×4 | |
LCD Size | 46mm X 42mm | |
Product Colour | Red and Grey | |
Product Net Weight | 601g | |
Product Size | 303mm X 112mm X 39mm | |
Standard Accessories | Test Lead, Batteries, Alligator Clips, USB Interface Cable, Tool Box, PC Software CD | |
Standard Individual Packing | Gift Box, English Manual | |
Based on 0 reviews
Be the first to review “UT243 Power and Harmonics Clamp Meters”
-
LCR Meter
UT612 LCR Meters
UT610 series is a handheld LCR digitalelectric bridge meter with stable performance, safety, reliability and autorange. It is professional to measure inductance, capacitance and resistance. Ithas the features of low power dissipation, high accuracy and fast speed. It canselect the series-parallel measurement mode; measure the quality factor ofcomponents, the loss, the phase angle, equivalent resistance and DC resistance.It can provide up to 5 kinds of frequency under the inductance, capacitance andresistance mode to satisfy the actual requirement.
It is applicable to measuring and filtratingthe inductance, capacitance and resistance of lab, production line, maintenancepoint and teaching. It is the ideal tool of maintaining for many users.
SKU: n/a -
Insulation Tester
MIC-15k1 ,15kV Insulation Quality Analyzer
Features:
- Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
- It allows testing the electrical durability of the tested object – breakdown voltage indication.
- High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
- The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
- Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
- visual method (if power cables are visible along the entire length),
- reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
- Compatible with external software.
SKU: n/a -
Clamp Meters
UT 205A+
1. 1000A AC current measurement2. 1000V AC/DC voltage measurement3. 600A inrush current measurement (UT206A+)4. Temperature (UT206A+)5. NCV (UT206A+)6. ACV frequency 10Hz~10kHz7. Jaw opening: 45mm8. Resistance / capacitance / frequency measurement9. Auto range / backlight / low battery indication10. Continuity / diode / duty cycle11. MAX/MIN12. Data hold / flashlight / relative mode13. Auto power off14. CAT II 1000V/CAT III 600VSKU: n/a
There are no reviews yet.