-22%

UT890C+ TRMS Digital Multimeter

Availability:

19 in stock


1.6000 Counts; Measure voltage and current RMS.

2.The capacitance slot has REL function. Range is from 1pF to 99.99mF
3.The device can measure frequency of high accuracy. The min resolution is 0.001Hz

4.It has special functions: MAX/MIN and MAX-MIN
5.The min DC and AC resolution is 0.01μA and 1μA. The max range is 20A.
6.It can measure diode  whose voltage drop is up to 3V .So it is very suitable to measure LED.
7.It has functions: hold, power off and backlight.
8.It also measure temperature ℃ and ℉

4,600 5,914

19 in stock

Compare

1.6000 Counts; Measure voltage and current RMS.

2.The capacitance slot has REL function. Range is from 1pF to 99.99mF
3.The device can measure frequency of high accuracy. The min resolution is 0.001Hz

4.It has special functions: MAX/MIN and MAX-MIN
5.The min DC and AC resolution is 0.01μA and 1μA. The max range is 20A.
6.It can measure diode  whose voltage drop is up to 3V .So it is very suitable to measure LED.
7.It has functions: hold, power off and backlight.
8.It also measure temperature ℃ and ℉

Category:
Weight 0.4 kg
Dimensions 18 × 9 × 6 cm
Basic functions Range Basic accuracy
Model  UNI-T UT890C + UT890D
DC voltage V 600.0mV (0.5% + 4) (0.5% + 4)
6.000V / 60.00V / 600.0V (0.5% + 2) (0.5% + 2)
1000V (0.7% + 10) (0.7% + 10)
AC voltage V 6.000V / 60.00V / 600.0V (0.8% + 3) (0.8% + 3)
750V (1.0% + 10) (1.0% + 10)
AC current A 6.000mA / 60.00mA (1.0% + 12) (1.0% + 12)
600.0mA (2.0% + 3) (2.0% + 3)
20.00A (3.0% + 5) (3.0% + 5)
A direct current 60.00A / 6.000mA / 60.00mA (0.8% + 8) (0.8% + 8)
600.0mA (1.2% + 5) (1.2% + 5)
20.00A (2.0% + 5) (2.0% + 5)
Resistance 600.0 (0.8% + 5) (0.8% + 5)
6.000k / 60.00k / 600.0k / 6.000M (0.8% + 3) (0.8% + 3)
60.00M (1.0% + 25) (1.0% + 25)
Temperature ℃ -400 ℃ ~ 1000 ℃ (1.0% + 3)
Temperature ℉ -40 ℉ ~ 1832 ℉ (1.5% + 5)
Capacitance F 6.000nF (5.0% + 35) (5.0% + 35)
60.00nF ~ 600.0F (2.5% + 20) (2.5% + 20)
6000F (5.0% + 10) (5.0% + 10)
Frequency Hz 9.999Hz ~ 9.999MHz (0.1% + 5) (0.1% + 5)
Measuring range: 10Hz ~ 10MHz (auto range), 100kHz:100mVrms input amplitude 30Vrms,
> 100kHz ~ 1MHz:200mVrms input amplitude 30Vrms, > 1MHz:600mVrms input amplitude 30Vrms
Special features
Max / Min
True RMS measurement TRMS
Frequency response Applicable sine wave and triangular wave,
200Hz other waveforms for reference
40Hz ~ 1kHz
Diode test
Continuity Buzzer
hFE
REL
Data Hold
LCD backlight
Battery voltage tips
Automatic shutdown About 15 minutes
Input impedance 10M
General Characteristics
Environment 18 C ~ 28 C (64 F ~ 82 F); relative humidity: 75%
Battery 9V battery (6F22)(Not included)
LCD size 63mm × 29mm
Colors Red + Grey
Body weight 300g
Dimensions 186mm × 91mm × 39mm
Standard accessories Table pen, temperature probe (onlyUT890C +)

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT890C+ TRMS Digital Multimeter”

There are no reviews yet.

  • A 830L DMM

    0 out of 5
    (0)
    SKU: n/a
  • ,

    JAKEMY JM-8194 Precision Screwdriver Pen Set

    0 out of 5
    (0)
    • Built-in high-precision bearings for a smooth rotation at every turn.
    SKU: n/a
  • YH ELEMENT FOR 948D

    0 out of 5
    (0)
    SKU: n/a
  • UT353-BT Mini Sound Level Meter

    0 out of 5
    (0)

    1. White backlight, clear LCD screen

    2. Adjustable sampling rate, fast/slow
    3. 1/2 inch condenser microphone
    4. Light weight, ergonomic design, user-friendly interface
    SKU: n/a
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a