TDR-420 Time Domain Reflectometer/ Cable Fault Locator

Availability:

Out of stock


Product features

  • Possibility damage-free location of impedance changes of tested cables and wires such as:
    • shorted conductor,
    • open conductor / end of cable – useful during the inventory of warehouses and stores,
    • splice,
    • splitter,
    • water ingress,
    • wet splice,
    • bridge tap
    • or other changes.
  • Single measurement mode ONCE,
  • Continuously measurement mode CONT,
  • Tone signal generator TONE,
  • Two cursors to mark two places of damage along with an indication of the distance between them,
  • Built-in HELP function for easier interpretation of the reflectogram,
  • 11 available measuring ranges from 7 m to 6000 m,
  • „dead zone” limited to 0.6 m,
  • Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
  • manually set of sensitivity in 8 steps GAIN,
  • output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
  • Velocity of Propagation set in range from 10% to 99%,
  • tight and durable housing with IP67 ingress protection degree.
  • Small size and weight.

0

Out of stock

Compare

TDR-420 is a hand held Time Domain Reflectometer designed to identify and locate faults in power, telecommunications and teletechnical cables. TDR-420 reflectometer allows to measure the length of the cable and determine the distance to damage or impedance variation in the range of 4 m to 6000 m in conductors with metal wires. The shortest measuring range of 7 meters and a dead zone of 0.6 meters allows to locate damages at a very close distance from the place where the device is connected.

Two cursors allow to determine the place of two damages simultaneously and the distance between them.

Thanks to the color 3,5” TFT display with a resolution of 320 x 240 pixels, the indication of the location of the damage is precise and the results easier to interpret.

Difficult environment conditions during measurement work are frequent problems encountered by electric installers and maintenance services. Thanks to the unique housing TDR-420 ensure a degree of protection on IP67 level, what means dustproof and protection against water penetration during short-term immersion. Therefore, working in very dusty terrain or accidental contact of the device with water will not affect the correct operation of the reflectometer.

 

Technical specification

  • Measurement ranges: 7, 15, 30, 60, 120, 250, 500 m, 1, 2, 3, 6 km / 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 20000 ft
  • Accuracy:1% of selected range
  • Resolution: Approx. 1% of selected range
  • Min. Cable length: 4 m / (14 ft)
  • Velocity of propagation VoP: Adjustable from 10 to…99% or 15…148,5 m/µs
  • Output Pulse: 5 Vp-p (open circuit)
  • Output Impedance: 25, 50, 75, 100, 120, 200 Ω
  • Output Impedance: 3 ns…3 µs (depends of range)
  • Scan rate / mode: Up to 3 scans / second (CONT) or single (ONCE)
  • Tone generator: 810 … 1110 Hz
  • Battery Life: Up to 8 hours of continuous scan
  • Power supply: 4 x alkaline batteries 1.5 V type AA or 4 x rechargeable batteries NiMH AA
  • Auto-OFF: 1, 3, 5, 10, 15 minutes or deactivated
  • Display: Color 3,5” LCD TFT, 320 x 240 pixels
  • Voltage protection: 400 V DC / 250 V AC
  • Dimensions: 220 x 98 x 58 mm (8.7 x 3.9 x 2.3 inches)
  • Weight: 487 g
  • Electromagnetic standard compatibility EMC: EN 61326-1
  • Water/ Dust Proof: IP67

Nominal condition of use

  • Operating temperature: -20..+70°C
  • Storage temperature: -30…+80°C at humidity <80%

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “TDR-420 Time Domain Reflectometer/ Cable Fault Locator”

There are no reviews yet.

  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a
  • CMM-11 Multimeter

    0 out of 5
    (0)
    • manual and automatic range selection
    • HOLD function for holding measured values
    • MAX/MIN” function for displaying extreme values
    • compact housing  – allows to store the device in a pocket
    • increased resistance to falls from heights above 2 m thanks to the elastomer coating
    • built-in Bluetooth module for data transfer to mobile devices
    • built-in flashlight for lighting the measuring places
    • Beeper for sound signal circuit continuity
    • Auto-OFF function for automatic switching off of the unused device
    • display 3¾ digit (count max 4000)
    SKU: n/a
  • UT60C Modern Digital Multimeters

    0 out of 5
    (0)

    Product Features

    1. Analogue bar graph

    2. Diode test and buzzer continuity

    3. Transistor measurement

    4. Auto range

    5. MAX/MIN/REL measurement mode

    SKU: n/a
  • YH 950 IRON FOR YH 950

    0 out of 5
    (0)
    SKU: n/a