-29%

Battery Load Tester – BT 100D

Availability:

7 in stock


  • 100 Amp Digital Battery Load Tester
  • Microprocessor Control–makes for an easy and accurate load test with no need to time yourself
  • Bright, LED Digital Display–indicates both voltage and test results
  • Unique 3-Step Design–LED polarity check function, battery load test and charging system test readout
  • Super-Grip Battery Clamps–heavy-duty and color-coded
  • Baked Enamel, Steel Case–ventilated to keep cool
  • Rubber Insulated Carrying Handle–for comfort and safety
  • Checks both Battery and Charging System

5,000 7,000

7 in stock

Compare

The BT-100D 100+ Amp Digital Battery Load Tester is microprocessor controlled. It makes for an easy and accurate load test with no need to time yourself to get accurate results. Bright, LED Digital Display indicates both voltage and test results. A unique 3-Step Design provides LED polarity check function, battery load test and charging system test readout. Automatically Turns Off the Load after 10 seconds and locks the voltage. Super-Grip Battery Clamps are heavy-duty and color-coded. Baked Enamel, Steel Case to keep cool. Rubber Insulated Carrying Handle–for comfort and safety. Checks both Battery and Charging System.

Category: Tag:
Weight 0.7 kg
Dimensions 15 × 8 × 6 cm

12 Volt Battery Analysis

Press “START TEST” & wait for 10 seconds.
Once automatic test cycle is completed, your test results will be:

1.
 GREEN LIGHT = OK):
Battery capacity is good. May or may not be fully charged.
Determine state of charge by checking specific gravity (use hydrometer). If gravity is less than full charge, check for possible charging system trouble or electrical drain. Recharge battery to fully charged level.

2. GREEN + YELLOW LIGHT = OK BUT WEAK):
Review the load test result with the comparison chart on the tester cover to see if this battery is “OK” or not. If it is “OK”, go up to 1ST “OK” state. If it is not, go down to 3rd “WEAK” state.

3. YELLOW LIGHT = WEAK):
Battery capacity is unsatisfactory. Battery may be either: (1) defective or (2) partially discharged. To determine which, check specific gravity. If gravity is over 1.225, battery is considered defective. If gravity is under 1.225, recharge battery and re-test. If cell-to-cell gravity varies more than 0.025 (25 points), cell trouble may exist. If charging does not bring gravity to fully charged level, the battery is either sulfated or has lost active material.

4. RED LIGHT = BAD):
Battery may be defective (e.g. a bad cell).

NOTE: If pre-test battery voltage is below 12.3V, tester will not allow and should not perform the load test. Please fully charge battery and retest.

Brand

TITAN

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Battery Load Tester – BT 100D”

There are no reviews yet.

  • AC/DC DIGITAL CLAMP METER KT 203

    0 out of 5
    (0)

    AC/DC DIGITAL CLAMP METER KT 203

    • Small and handy clamp meter
    • IEC 6101C Clamp meter
    • DMM function A0-1 Safety Standard CAT Ⅲ 300V, CAT Ⅱ 600V

    • 400A AC/DCV, DCV, Ω, Continuity Buzzer.

    SKU: n/a
  • High-temperature repair mats V56 480*320mm

    0 out of 5
    (0)

    High-temperature repair mats V56 480*320mm

    SKU: n/a
  • A13T Temperature Humidity Meter

    0 out of 5
    (0)

    1. Sampling time: 10s

    2. Display of temperature, humidity, date and time
    3. Clock function: 12/24 hour modes
    4. Alarm clock: Rings up to 60s
    5. ℃/℉ selectable
    SKU: n/a
  • MIC-5001, 5000V Insulation Tester

    0 out of 5
    (0)

    Insulation resistance measurement in a compact, light-weight, low-cost design.

    • Measurement to 5 TΩ
    • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
    • Continuous indication of insulation resistance or leakage current
    • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
    • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
    • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
    • Continuous display of test voltage during the measurement
    • Protection against measuring live objects
    • Two and three-lead measurement method
    • Ramp Test Insulation resistance measurement
    • Measurement of breakdown voltage with increments up to 1 kV / s
    • Measurement of alternating and direct voltages from 0 V to 750 V
    • 990 cells of memory (11880 records) to record results
    • Data transfer to PC via USB cable
    • Built-in rechargeable battery pack
    • Meets the requirements of the EN 61557 standard
    • Charge from optional car lighter (12 V) socket accessory
    SKU: n/a
  • MRU-21 Earth Resistance Meter

    0 out of 5
    (0)

    Possible measurements:

    • earth resistance measurment with 3-pole method,
    • measurement of continuity of equipotential bondings and protective conductors with auto-zero function – with current 200 mA,
    • resistance measurement using 2-pole method.
    SKU: n/a
  • UT683KIT Wire Tracker

    0 out of 5
    (0)

    Features of UT683KIT Wire Tracker

    Certifications: CE, UKCA

    ● Line function

    ● NCV function

    ● Withstand voltage DC 60V

    ● Port flashes

    SKU: n/a