-6%

UT210E ACA DCA Digital Clamp Meters


Main Features

1. Auto range, 2~3/s sampling rate

2. True RMS measurement

3. VFC, frequency conversion function

4. NCV, Non-Contact Voltage testing function:induce electric field strength via the jaw

5. Zero mode

6. LCD backlight, data hold

7. Auto power off, low battery indication and overload protection

8. Comfortable to hold and easy to carry with (Product weight: 160g/170g)

9. Complies with CE (European Union) directives

13,200 14,026

Compare

Main Features

1. Auto range, 2~3/s sampling rate

2. True RMS measurement

3. VFC, frequency conversion function

4. NCV, Non-Contact Voltage testing function:induce electric field strength via the jaw

5. Zero mode

6. LCD backlight, data hold

7. Auto power off, low battery indication and overload protection

8. Comfortable to hold and easy to carry with (Product weight: 160g/170g)

9. Complies with CE (European Union) directives

Category:
Weight 0.2 kg
Dimensions 17 × 6 × 3 cm
Specifications Range Best Accuracy
Model UT210E
AC Current (A) 20A/200A
2A/20A/100A ±(2.5%+5)
DC Current (A) 20A/200A
2A/20A/100A ±(2%+3)
AC Voltage (V) 2V/20V/200V/600V ±(1%+3)
DC Voltage (V) 200mV/2V/20V/200V/600V ±(0.7%+3)
Resistance (Ω) 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ ±(1%+2)
Frequency 10Hz/100Hz/1kHz/10kHz/60kHz
Capacitance    (F) 2nF/20nF/200nF/2μF
/20μF/200μF/2mF/20mF
±(4%+5)
Temperature (℃) -40~1000℃
Temperature (℉) -40~1832℉
Features
Display Count 2000
Auto Range
Jaw Capacity 17mm
True RMS
Diode Around 3.0V
V.F.C.
NCV
Auto Power Off Around 15 minutes
Continuity    Buzzer
Low Battery Indication ≤2.5V
Data Hold
Zero Mode
MAX/MIN
LCD Backlight
Input    Protection
Input Impedance for DCV ≥10MΩ
General Characteristics 
Power AAA 1.5V x 2
LCD Size 39.3mm x 26.5mm
Product Color Red and grey
Product Net Weight 170g
Product Size 175mm x 60mm x 33.5mm
Standard Accessories Batteries, Test Lead
Standard Individual Packing Gift  Box, Carrying bag, English Manual

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT210E ACA DCA Digital Clamp Meters”

There are no reviews yet.

  • UNI-T MSO3154E 150MHz Mixed Signal 4 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • DIGITAL INSULATION / CONTINUITY TESTER MODEL 3007A

    0 out of 5
    (0)

    • Bargraph to display insulation resistance.
    • Displays the value of external AC voltage along with flashing symbol.
    • Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
    • Trac-Lok mode to conserve battery life on insulation and continuity tests.
    • Live circuit warning beeper.
    • Releasing the test button automatically discharges the charges stored in the circuit under test.
    • Backlight function to view the test results in dimly lit areas.
    • 200mA continuity measuring current to IEC 61557.
    • Minimum 1mA current on insulation tests to IEC 61557.

    SKU: n/a
  • JM T10-12 TEWZER

    0 out of 5
    (0)
    SKU: n/a
  • Pride Cutter Plier 6″ With Rubber Grip Handle

    0 out of 5
    (0)

    Pride Cutter Plier 6″ With Rubber Grip Handle

    SKU: n/a
  • MC TIP OT IS

    0 out of 5
    (0)
    SKU: n/a
  • UT283A Single Phase Power Quality Analyzer

    0 out of 5
    (0)

    1. Trend/event capture

    2. Harmonics/inrush current measurement
    3. File management through USB interface
    4. Flick measure (PST/PLT values)
    5. User friendly interface
    6. Multimeter functions
    7. Scope functions including waveform display
    8. 3.5 inches 64K color TFT LCD display
    9. THD (Total Harmonic Distortion) function
    10.Long-term monitoring
    SKU: n/a