Industrial multimeter CMM-40 was designed for the purpose of measurements of AC/DC voltage, AC/DC current, resistance, capacitance, frequency (electrical and electronic), duty cycle, temperature and also for testing diodes and continuity.
CMM-40 Industrial Multimeter
5 in stock
The most important features of CMM-40 are:
- autoranging/manual range selection,
- „DATA HOLD” function, for holding measured values,
- „REL” function, which allows you to make measurements relative to a stored reference value,
- „MAX/MIN” function,
- „PEAK HOLD” function,
- memory for 2000 measurement resultS,
- continuity test with acoustic signalling (beeper),
- „AUTO-OFF” function,
- display 4¾ digits (40000 max),
- double molded, waterproof casing.
₨30,270 ₨34,221
5 in stock
CompareWeight | 0.4 kg |
---|---|
Dimensions | 19 × 8 × 5 cm |
Frequency measurement (electronic)
Range | Resolution | Accuracy |
40,000 Hz | 0,001 Hz | ±(0,1% m.v. + 1 digit) |
400,00 Hz | 0,01 Hz | |
4,0000 kHz | 0,0001 kHz | |
40,000 kHz | 0,001 kHz | |
400,00 kHz | 0,01 kHz | |
4,0000 MHz | 0,0001 MHz | |
40,000 MHz | 0,001 MHz | |
100,00 MHz | 0,01 MHz | not speccified |
- Sensitivity: 0.8 V rms min. @ 20% to 80% duty cycle and <100 kHz; 5 V rms min @ 20% to 80% duty cycle and > 100 kHz
Frequency measurement (electrical)
Range | Resolution | Accuracy |
40,00 Hz…10,000 kHz | 0,01 Hz…0,001 kHz | ± 0,5% m.v. |
- sensitivity: 1 V rms
Duty cycle measurement
Range | Resolution | Accuracy |
0,10…99,00% | 0,01% | ±(1,2% m.v. + 2 digits) |
- pulse width: 100μs – 100 ms,
- frequency width: 5 Hz…150 kHz.
Temperature measurement
Range | Resolution | Accuracy |
-50,0°C…+1200,0°C | 0,1°C | ±(1% m.v. + 2,5°C) |
-58,0°F…+2192,0°F | 0,1°F | ±(1% m.v. + 4,5°F) |
DC voltage measurement
Range | Resolution | Accuracy |
400,0 mV | 0,01 mV | ±(0,06% m.v. + 4 digits) |
4,0000 V | 0,0001 V | |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V | ±(0,1% w.m. + 5 cyfr) |
AC voltage measurement (True RMS)
Range | Resolution | Accuracy |
400,00 mV | 0,01 mV | ±(1% m.v. + 40 digits) |
4,0000 V | 0,0001 V | ±(1% m.v. + 30 digits) |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V |
- frequency range: 50…1000 Hz.
AC/DC current measurement (True RMS)
Range | Resolution | Accuracy |
400,00 μA | 0,01 μA | dla DC ±(1,0% m.v. + 3 digits)
dla AC ±(1,5% m.v. + 30 digits) |
4 000,0 μA | 0,1 μA | |
40,000 mA | 0,001 mA | |
400,00 mA | 0,01 mA | |
10,000 A | 0,001 A |
- 20 A: 30 sec max with reduced accuracy.
Resistance measurement
Range | Resolution | Accuracy |
400,00 Ω | 0,01 Ω | ±(0,3% m.v. + 9 digits) |
4,0000 kΩ | 0,0001 kΩ | ±(0,3% m.v. + 4 digits) |
40,000 kΩ | 0,001 kΩ | |
400,00 kΩ | 0,01 kΩ | |
4,0000 MΩ | 0,0001 MΩ | |
40,000 MΩ | 0,001 MΩ | ±(2,0% m.v. + 10 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
40,000 nF | 0,001 nF | ±(3,5% m.v. + 40 digits) |
400,00 nF | 0,01 nF | |
4,0000 μF | 0,0001 μF | ±(3,5% m.v. + 10 digits) |
40,000 μF | 0,001 μF | |
400,00 μF | 0,01 μF | |
4000,0 μF | 0,1 μF | ±(5% m.v. + 10 digits) |
40,000 mF | 0,001 mF |
Other technical data:
- power supply: 9 V battery type 6LR61
- diode test: I=0,9 mA, U0 = 2,8 V DC
- continuity test: I<0,35 mA, sound signal for R<35 Ω
- over range indication: 0L displayed
- crest factor: ≤ 3 at full scale up to 500 V; decreasing linearly to ≤ 1,5 at 1000 V
- PEAK: captures peaks >1 ms
- sampling rate: 2 times per second
- input impedance: 10 MΩ (V DC), 9 MΩ (V AC)
- display: 40000 counts backlit LCD with bargraph, 4¾ digits
- store capacitance: 2000
- dimensions: 187 x 81 x 55 mm
- weight: 342 g
- fuses: mA, µA range: 0,5 A/1000 V ceramic fast blow; A range: 10 A/1000 V ceramic fast blow
- auto power OFF: 15 min.
- accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
Electric security:
- type of insulation: double, according to EN 61010 – 1 and IEC 61557
- measurement category: CAT III 1000 V acc. to EN 61010 – 1:2004
- protection class acc. to EN 60529: IP67
Rated operational conditions:
- operating temperature: 0…+40°C
- storage temperature: -20…+60°C
- operating humidity: max 80% up to 87°F (31°C); decreasing linearly to 50% at 104°F (40°C)
- operating altitude: max 2000 m
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMM-40 Industrial Multimeter”
-
LCR Meter
UT612 LCR Meters
UT610 series is a handheld LCR digitalelectric bridge meter with stable performance, safety, reliability and autorange. It is professional to measure inductance, capacitance and resistance. Ithas the features of low power dissipation, high accuracy and fast speed. It canselect the series-parallel measurement mode; measure the quality factor ofcomponents, the loss, the phase angle, equivalent resistance and DC resistance.It can provide up to 5 kinds of frequency under the inductance, capacitance andresistance mode to satisfy the actual requirement.
It is applicable to measuring and filtratingthe inductance, capacitance and resistance of lab, production line, maintenancepoint and teaching. It is the ideal tool of maintaining for many users.
SKU: n/a -
Soldering Iron
YH 133A ELEMENT FOR 907A,907C
Features Of Soldering Iron Heating Element YH-133A For 907A,907C:
- Suitable for YIHUA 936, 937D, 878serial, 852 serial, 898D, 898BD, 862D, 8786D, 868D and so on.
- If the soldering iron is burned, use the heating core to replace the old one.
- Stainless steel materials.
- Fast heating.
- 100% brand new product.
- Made of high-quality material.
SKU: n/a -
Environment Meters
UT343D Coating Thickness Gauge
UT343D coating thickness gauge can measure coating thickness on ferrous and non-ferrous materials. This device is designed with a unique quick test feature, which allows users to set thickness range and using a 3-color LED and audio alarm to quickly determine if coating being tested falls within the preset range, greatly increasing work efficiency.