-13%

EARTH TESTER KEW 4105A


• In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
(unit can be hung from the neck for simplified measurement)
• The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 60529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.

58,500 67,000

Compare

EARTH TESTER KEW 4105A

• In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
(unit can be hung from the neck for simplified measurement)
• The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 60529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.

Category:
Earth resistance
measurement
20Ω 200Ω 2000Ω
Measuring range 0.00 – 1999Ω
Display range 0.00 – 19.99Ω 0.0 – 199.9Ω 0 – 1999Ω
Accuracy ±2%rdg±0.1 Ω ±2%rdg±3dgt
Earth voltage measurement
Measuring range 0 – 200 V AC (50,60Hz)
Display range 0.0 – 199.9 V
Accuracy ±1%rdg±4dgt
Overload protection Earth resistance : 280V AC (10 seconds)
Earth voltage : 300V AC (1 minute)
Applicable Standards IEC 61010-1 CAT Ⅲ300 V Pollution degree 2
IEC 61010-2-030, IEC 61557-1, -5, IEC 60529 (IP54)
Power source R6(AA)(1.5V) × 6
Dimensions 105(L) × 158(W) × 70(D) mm (including case lid)
Weight Approx. 550g (including batteries and case lid)
Accessories 7095A (Earth resistance test leads [red-20m, yellow-10m, green-5m/1set])
7127B (Simplified measurement probe),
8032 (Auxiliary earth spikes[2 spikes/1set]),
9121 (shoulder strap),
9084 (Soft case)
R6(AA) × 6, Instruction manual
Optional 7245A (Precision measurement cord set)
8259 (Adapter for measurement terminal)
9165 (Hard case)

Brand

KYORITSU

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “EARTH TESTER KEW 4105A”

There are no reviews yet.

  • UT300A+ Infrared Thermometer

    0 out of 5
    (0)

    1. Simple one button operation

    2. 10:1 D:S ratio
    3. Data hold
    4. Backlight
    5. Temperature range: -20℃~400℃
    SKU: n/a
  • MECHANIC Industrial Triocular stereo microscope MC75T-B1

    0 out of 5
    (0)

    MECHANIC Industrial Triocular stereo microscope MC75T-B1

    Binocluar magnification(7X-45X/2.1X-180X)

    Eyepiece(WF10X/20MM,WF20X/10MM)

    Objectlens(10.6X-5.5X),

    Aux(0.3X/287,0.5X/165,0.7X/120,1.5X/45,2X/30)

    Continuourszoom(0.7X-4.5X)

    SKU: n/a
  • TKF-12 Phase Sequence Tester

    0 out of 5
    (0)

    Phase sequence indication (direction of field rotation) in the power network with rated phase-to-phase voltage (120…690 V) AC by LED signalization.
    Operation in the power network with frequency range 10…70 Hz.

    Indication of the voltage presence in the particular phases by neon lamps signalization.
    Power supply from the tested network (continuous operation to 15 minutes for max. voltage).
    Protection against faulty indication of field rotation.

    SKU: n/a
  • TDR-420 Time Domain Reflectometer/ Cable Fault Locator

    0 out of 5
    (0)

    Product features

    • Possibility damage-free location of impedance changes of tested cables and wires such as:
      • shorted conductor,
      • open conductor / end of cable – useful during the inventory of warehouses and stores,
      • splice,
      • splitter,
      • water ingress,
      • wet splice,
      • bridge tap
      • or other changes.
    • Single measurement mode ONCE,
    • Continuously measurement mode CONT,
    • Tone signal generator TONE,
    • Two cursors to mark two places of damage along with an indication of the distance between them,
    • Built-in HELP function for easier interpretation of the reflectogram,
    • 11 available measuring ranges from 7 m to 6000 m,
    • „dead zone” limited to 0.6 m,
    • Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
    • manually set of sensitivity in 8 steps GAIN,
    • output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
    • Velocity of Propagation set in range from 10% to 99%,
    • tight and durable housing with IP67 ingress protection degree.
    • Small size and weight.
    SKU: n/a