Key features

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

21,058

Out of stock

Compare

Fluke quality is always within your reach

Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B+ digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B+ offers everything you need.

Category:

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 15B+ Digital Multimeter”

There are no reviews yet.

  • DT 830D DMM

    0 out of 5
    (0)
    SKU: n/a
  • UT 892

    0 out of 5
    (0)

    Features of UT892 2000V AC/DC High Voltage Digital Multimeter

    ● 6000 counts True RMS

    ● 2000V AC/DC voltage measurement
    ● VFC 600V voltage measurement
    ● LIVE test
    ● 60MΩ resistance/60mF capacitance
    ● 10kHz frequency measurement
    ● Test lead indication
    ● Backlight
    ● NCV
    ● CAT II 1000V/CAT III 600V
    SKU: n/a
  • UT206 1000A ACA Digital Clamp Meters

    0 out of 5
    (0)

    UT206A is a professional 1000A AC digital clamp meter with 40mm jaw. It is suitable for conductors up to 500MCM and the new structure is ergonomically designed. UT205A is the first choice for electricians to do electrical testing.

    SKU: n/a
  • TDR-410 Cable Fault Locator

    0 out of 5
    (0)
    • Features:

      • automatic or manual mode:
        • the automatic fault location (AFL),
        • mode with manual range selection and sensitivity,
        • single measurement triggered manually or scanning continuous,
      • 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
      • maximum length of cable up to 4000 m one end of the cable,
      • “Dead zone” measure limited to 0.5 m,
      • 2.5 “LCD screen with backlight,
      • scan automatically or manually trigger,
      • sensitivity set manually or automatically adjusted,
      • adjustable impedance matching,
      • propagation coefficient adjustment 1% to 99%,
      • waterproof and resistant to mechanical housing.
      • small size and weight.
      • economical power system – 30 hours of continuously scan on one battery set..

      Accessories:

      • 0,6 m double-wire lead: WAPRZ0X6DZBB
      • red crocodile clip: WAKRORE20K02
      • Krokodylek czarny: WAKROBL20K01
      • cover M-2: WAFUTM2
    SKU: n/a
  • LKZ-720 Wires and pipe locator

    0 out of 5
    (0)

    Features:

    • the function 3D in the receiver – detecting the direction of current flow and accurate locating the object,
    • phase detection mode,
    • receiver operation with four transmitters at the same time to locate interruptions or distinguish wires,
    • a LED bright torch,
    • headphone socket in receiver,
    • screens backlight for work in dark,
    • transmission battery status and settings of the transmitter to the receiver
    • operation in wide range of rated voltage, up to 500V RMS,
    •  measurement of voltage at the object to 500 Vrms,
    • three levels of transmitter amplification,
    • automatic or manual selection of transmitter operation modes,
    • five modes of wire tracer operation – voltage, current, current-voltage, power and clamp,
    • software upgrade via USB,
    • additional accessories enable precise localization – such as contact or non-contact probes and measurement clamp.
    SKU: n/a
  • UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V) (Discontinued)

    0 out of 5
    (0)

    Features of UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V)

    Certifications: CE, RoHS, UL

    ● Complies with CAT IV 600V (UT13A); prevent damage caused by transient voltage
    ● CAT IV 1000V (UT13B)
    ● LED indication
    ● Vibration indication (UT13B)
    ● Adjustable sensitivity

    SKU: n/a