Feature:

-New Function:Frequency Test

-New Desgin: A Large LCD than FLUKE 18B, with a high brightness LCD Back light

-Two Mode LED Test :

-DMM LED Socket Test Mode .

-UUT(PCBA) LED Test Mode(using test lead).

-Light up LED without considering the polarity.

-Voltage,Resistance,Continuity Testing,Capacitance Test.

-Data Hold,Diode Test.

-Frequency and Duty Cycle.

-MAX Input Current 10A.

 

 

30,270 32,905

Out of stock

Compare

FLUKE 18B+ AC/DC Voltage,Current,Capacitance,Ohm Auto/Manual Range Digital multimeter with LED Test

Category:
Weight 1 kg
Dimensions 16 × 8 × 9 cm

Specifications:

 

Feature Range Resolution Accuracy
AC Voltage(40-500Hz) 4.000 V

40.00 V

400.0 V

1000 V

0.001 V

0.01 V

0.1 V

1 V

1.0 % + 3
DC Voltage 4.000 V

40.00 V

400.0 V

1000 V

0.001 V

0.01 V

0.1 V

1 V

0.5 % + 3
AC Voltage(mV) 400.0 mV 0.1 mV 3.0 % + 3
DC Voltage(mV) 400.0 mV 0.1 mV 1.0 % + 10
Diode 2.000 V 0.001 V 10%
Resistance 400.0 Ω

4.000 kΩ

40.00 kΩ

400.0 kΩ

4.000 MΩ

40.00 MΩ

0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ

0.5 % + 3

0.5 % + 2

0.5 % + 2

0.5 % + 2

0.5 % + 2

1.5% + 3

Capacitance 40.00 nF

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF

0.01 nF

0.1 nF

0.001 μF

0.01 μF

0.1 μF

1 μF

2 % + 5

2 % + 5

5 % + 5

5 % + 5

5 % + 5

5 % + 5

Frequency 50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

0.1 % + 3
Duty Cycle 1 % to 99 % 0.1%
AC Current

uA (40-400Hz)

400.0 μA

4000 μA

0.1 μA
1 μA
1.5 % + 3
AC Current

mA(40-400Hz)

40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3
AC Current

A(40-400Hz)

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3
DC Current (uA) 400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3
DC Current (mA) 40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3
DC Current (A) 4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

 

LED Test and On-off Threshold:

 

Feature Lighting Range measuring range Resolution Accuracy
LED VF Test(LED Test Socket) 1.00-6.00V N/A N/A N/A
LED VF Test(Test Lead) 1.00-6.00V 1.00-6.00V 0.01V 10%
On-off threshold N/A N/A N/A 70Ω

 

Input Parameter:

 

Feature Overload Protect Input Impedance Common Mode Rejection Ratio Conventional mode rejection ratio
AC Voltage 1000V >10MΩ,<100pF DC,Frequency Between 50Hz to 60Hz, >60dB N/A
AC Voltage(mV) 400mV >1MΩ,<100pF Frequency Between 50Hz to 60Hz,>80dB N/A
DC Voltage 1000V >10MΩ,<100pF DC,Frequency Between 50Hz to 60Hz,>100dB Frequency Between 50Hz to 60Hz,>60dB
DC Voltage(mV) 400mV >1MΩ,<100pF Frequency Between 50Hz to 60Hz,>80dB N/A

 

Package Included:

Fluke 18B+*1

Test Lead*1

Manual *1

Battery(Not Included)

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 18B+ Digital Multimeter”

There are no reviews yet.

  • JM-6112 69 in 1 Screwdriver Set

    0 out of 5
    (0)

    Main Features:
    ● Universal screwdriver tool kit
    ● Highly precise tips in various specifications for different uses
    ● Non-slip rubber design handle for a secure and comfortable grip, easy to operate

    SKU: n/a
  • MECHANIC halogenfree flux paste UV80 [60G]

    0 out of 5
    (0)

    Containing high quality rosin, the use of acid – free flux refined,

    semi – solid is not easy to dump

    Non – corrosive, easy to weld, quick cleaning and good insulation, no acid

    SKU: n/a
  • UNI-T UTi260E Professional Handheld IR Thermal Camera 256×192 pixels Wide Temperature -20ºC~550ºC with PC,WiFi,App Real Time Display

    0 out of 5
    (0)

    UTi260B

    Motor inspection:
    Using UNI-T thermal imager can detect the imbalance loading, overloading, wiring error and parts malfunction etc. Heat insulation protection is the key action for avoid fire risk, engineer can also use the thermal imager check the protection situation regularly to ensure the safety production.

    PCBA inspection:
    Using UNI-T thermal imager can quickly locate the components where temperature is abnormally higher.

    Electric inspection:
    Using UNI-T thermal imager to check the device temperature can find the problems in time on switcher, contactor, transformer etc, which maybe caused by oxidation, corrosion, poor contact.

    SKU: n/a
  • CLAMP METER AC BM 528D

    0 out of 5
    (0)
    SKU: n/a
  • UT12M-US AC Voltage Detector

    0 out of 5
    (0)

    features:
    1. Auto power off
    2. Buzzer
    3. LED indication
    4. IP 67
    5. AC voltagedetection
    6. High/Lowvoltage mode
    7. Magnetic solenoiddetection

    Applications:
    Low voltage mode: Low-voltage motor (<90V), audio systems, arc welding machines,underground mining lighting, cables with thick insulation layer and other weakelectromagnetic AC signals.
    High voltage mode: Urban electric supply and three-phase systems (90~1000V). Forexample, power distribution units, electrical panels, electrical appliances.

    SKU: n/a
  • UT377A Wood Moisture Meter

    0 out of 5
    (0)

    UT377A is a digital meter designed to measure the moisture content of wood, paper, plywood, and other wooden materials. This device classifies wood into four categories based on material density, and applies temperature compensation algorithm to ensure measurement accuracy. UT377A’s miniature design, low power consumption, and high precision all make this a great product choice for measuring wood moisture content.

    SKU: n/a