-8%

Fluke 18B+ Digital Multimeter

Availability:

Out of stock


Feature:

-New Function:Frequency Test

-New Desgin: A Large LCD than FLUKE 18B, with a high brightness LCD Back light

-Two Mode LED Test :

-DMM LED Socket Test Mode .

-UUT(PCBA) LED Test Mode(using test lead).

-Light up LED without considering the polarity.

-Voltage,Resistance,Continuity Testing,Capacitance Test.

-Data Hold,Diode Test.

-Frequency and Duty Cycle.

-MAX Input Current 10A.

 

 

30,270 32,905

Out of stock

Compare

FLUKE 18B+ AC/DC Voltage,Current,Capacitance,Ohm Auto/Manual Range Digital multimeter with LED Test

Category:
Weight 1 kg
Dimensions 16 × 8 × 9 cm

Specifications:

 

Feature Range Resolution Accuracy
AC Voltage(40-500Hz) 4.000 V

40.00 V

400.0 V

1000 V

0.001 V

0.01 V

0.1 V

1 V

1.0 % + 3
DC Voltage 4.000 V

40.00 V

400.0 V

1000 V

0.001 V

0.01 V

0.1 V

1 V

0.5 % + 3
AC Voltage(mV) 400.0 mV 0.1 mV 3.0 % + 3
DC Voltage(mV) 400.0 mV 0.1 mV 1.0 % + 10
Diode 2.000 V 0.001 V 10%
Resistance 400.0 Ω

4.000 kΩ

40.00 kΩ

400.0 kΩ

4.000 MΩ

40.00 MΩ

0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ

0.5 % + 3

0.5 % + 2

0.5 % + 2

0.5 % + 2

0.5 % + 2

1.5% + 3

Capacitance 40.00 nF

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF

0.01 nF

0.1 nF

0.001 μF

0.01 μF

0.1 μF

1 μF

2 % + 5

2 % + 5

5 % + 5

5 % + 5

5 % + 5

5 % + 5

Frequency 50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

0.1 % + 3
Duty Cycle 1 % to 99 % 0.1%
AC Current

uA (40-400Hz)

400.0 μA

4000 μA

0.1 μA
1 μA
1.5 % + 3
AC Current

mA(40-400Hz)

40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3
AC Current

A(40-400Hz)

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3
DC Current (uA) 400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3
DC Current (mA) 40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3
DC Current (A) 4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

 

LED Test and On-off Threshold:

 

Feature Lighting Range measuring range Resolution Accuracy
LED VF Test(LED Test Socket) 1.00-6.00V N/A N/A N/A
LED VF Test(Test Lead) 1.00-6.00V 1.00-6.00V 0.01V 10%
On-off threshold N/A N/A N/A 70Ω

 

Input Parameter:

 

Feature Overload Protect Input Impedance Common Mode Rejection Ratio Conventional mode rejection ratio
AC Voltage 1000V >10MΩ,<100pF DC,Frequency Between 50Hz to 60Hz, >60dB N/A
AC Voltage(mV) 400mV >1MΩ,<100pF Frequency Between 50Hz to 60Hz,>80dB N/A
DC Voltage 1000V >10MΩ,<100pF DC,Frequency Between 50Hz to 60Hz,>100dB Frequency Between 50Hz to 60Hz,>60dB
DC Voltage(mV) 400mV >1MΩ,<100pF Frequency Between 50Hz to 60Hz,>80dB N/A

 

Package Included:

Fluke 18B+*1

Test Lead*1

Manual *1

Battery(Not Included)

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 18B+ Digital Multimeter”

There are no reviews yet.

  • CLAMP METER AC BM 2000B

    0 out of 5
    (0)

    SPECIFICATIONS:

    – Maximum display: 1999
    – Method indication: LCD
    – Maximum arm span: 60mm
    – Operating temperature range:
    work: 0C – 40C
    Storage:-10C – 60C
    – Power supply: 9V battery
    – Low battery indication: YES, graphic symbol
    – Audible indication: YES, piezoelectric transducer
    – Dimensions: 270x100x45 mm
    – Weight: about 610g (with battery)

    Features
    – Measuring voltage: 0-1000V 2 range
    – Measurement of AC voltage: 0-700V in 1 range
    – Measurement of alternating current: 200A-2000A in 2 ranges
    – Measuring current: 200A-2000A in 2 ranges
    – Measurement of resistance: 2k in 1 range
    – Measuring capacity: NO
    – Frequency: NO
    – Temperature measurement: NO
    – Testing LEDs: YES
    – Acoustic continuity tester: YES
    – Distance between arms: 6cm
    – Meter dimensions: 270x100x45 mm
    – Weight: 610g with battery
    – Basic accuracy: ± (0.5% +2 digits)

    Packages Include:

    1 × Clamp-On Meter BM-2000B

    An internal link is any link from one page on your website to another page on your website. Both your users and search engines use links to find content on your website. Your users use links to navigate through your site and to find the content they want to find. Search engines also use links to navigate your site. They won’t find a page if there are no links to it. There are several types of internal links. In addition to links on your homepage,mean post feed, etc, you can also add links within your content. We call those contextual links. Contextual links point your users to interesting and related content.
    SKU: n/a
  • AC DIGITAL CLAMP METER KEW 2117R

    0 out of 5
    (0)

    AC DIGITAL CLAMP METER KEW 2117R

    • Fully Safety jaw
    • Ergonomic over-molded body gives convenient one-hand operation
    • Large easy-to-read display with 0.01A resolution
    • Accurate reading with True RMS
    60/600/1000A auto-ranging
    • Long battery life
    • Safety Standard
    IEC 61010-1 CAT IV 300V / CAT III 600V

    SKU: n/a
  • LM 60 T Laser Tapes

    0 out of 5
    (0)

    Features of LM T Series Laser Tapes

    Certificates: CE, UKCA

    LM40T:

    ● One-button operation
    ● Single measurement
    ● Rear measurement reference
    ● Unit conversion
    ● Dual measurement methods
    ● Portable and compact

    LM60T:

    ● Single measurement

    ● Dual measurement mode
    ● Portable and compact
    ● Continuous measurement
    SKU: n/a
  • RF-6555TVP

    0 out of 5
    (0)
    SKU: n/a