FLUKE 18B+ AC/DC Voltage,Current,Capacitance,Ohm Auto/Manual Range Digital multimeter with LED Test
Fluke 18B+ Digital Multimeter
Out of stock
Feature:
-New Function:Frequency Test
-New Desgin: A Large LCD than FLUKE 18B, with a high brightness LCD Back light
-Two Mode LED Test :
-DMM LED Socket Test Mode .
-UUT(PCBA) LED Test Mode(using test lead).
-Light up LED without considering the polarity.
-Voltage,Resistance,Continuity Testing,Capacitance Test.
-Data Hold,Diode Test.
-Frequency and Duty Cycle.
-MAX Input Current 10A.
₨30,270 ₨32,905
Out of stock
CompareWeight | 1 kg |
---|---|
Dimensions | 16 × 8 × 9 cm |
Specifications:
Feature | Range | Resolution | Accuracy |
AC Voltage(40-500Hz) | 4.000 V
40.00 V 400.0 V 1000 V |
0.001 V
0.01 V 0.1 V 1 V |
1.0 % + 3 |
DC Voltage | 4.000 V
40.00 V 400.0 V 1000 V |
0.001 V
0.01 V 0.1 V 1 V |
0.5 % + 3 |
AC Voltage(mV) | 400.0 mV | 0.1 mV | 3.0 % + 3 |
DC Voltage(mV) | 400.0 mV | 0.1 mV | 1.0 % + 10 |
Diode | 2.000 V | 0.001 V | 10% |
Resistance | 400.0 Ω
4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω
0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3
0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
Capacitance | 40.00 nF
400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF |
0.01 nF
0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5
2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency | 50.00 Hz
500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz
0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
0.1 % + 3 |
Duty Cycle | 1 % to 99 % | 0.1% | |
AC Current
uA (40-400Hz) |
400.0 μA
4000 μA |
0.1 μA 1 μA |
1.5 % + 3 |
AC Current
mA(40-400Hz) |
40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5 % + 3 |
AC Current
A(40-400Hz) |
4.000 A
10.00 A |
0.001 A
0.01 A |
1.5 % + 3 |
DC Current (uA) | 400.0 μA
4000 μA |
0.1 μA
1 μA |
1.5 % + 3 |
DC Current (mA) | 40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5 % + 3 |
DC Current (A) | 4.000 A
10.00 A |
0.001 A
0.01 A |
1.5 % + 3 |
LED Test and On-off Threshold:
Feature | Lighting Range | measuring range | Resolution | Accuracy |
LED VF Test(LED Test Socket) | 1.00-6.00V | N/A | N/A | N/A |
LED VF Test(Test Lead) | 1.00-6.00V | 1.00-6.00V | 0.01V | 10% |
On-off threshold | N/A | N/A | N/A | 70Ω |
Input Parameter:
Feature | Overload Protect | Input Impedance | Common Mode Rejection Ratio | Conventional mode rejection ratio |
AC Voltage | 1000V | >10MΩ,<100pF | DC,Frequency Between 50Hz to 60Hz, >60dB | N/A |
AC Voltage(mV) | 400mV | >1MΩ,<100pF | Frequency Between 50Hz to 60Hz,>80dB | N/A |
DC Voltage | 1000V | >10MΩ,<100pF | DC,Frequency Between 50Hz to 60Hz,>100dB | Frequency Between 50Hz to 60Hz,>60dB |
DC Voltage(mV) | 400mV | >1MΩ,<100pF | Frequency Between 50Hz to 60Hz,>80dB | N/A |
Package Included:
Fluke 18B+*1
Test Lead*1
Manual *1
Battery(Not Included)
Based on 0 reviews
Be the first to review “Fluke 18B+ Digital Multimeter”
-
Digital Multi Meter
The Sanwa CD800a is a basic, portable, 4000 count digital multimeter
- 4000 counts
- 0.7% Best Accuracy
- Sharp contrast LCD with character 17.5mm high is used
- Solid & protective body cover that can also be used as a tilt stand
- Frequency, capacitance, and duty cycle measurement function
- Continuity test with buzzer
Includes meter, instruction manual and test leads.
SKU: n/a -
Laser Distance Meters
LM40 Laser Distance Meter
1. Ergonomic exterior, comfortable handling
2. Millimeter accuracy3. Large, multiple angle HD display5. Physical and electronics leveler6. Multiple functions: Max/Min/continuous measurement, displacement calculation, data storage, and more7. Auto power off after 3 minutes without operationSKU: n/a -
Wire & Cable Testers
TDR-420 Time Domain Reflectometer/ Cable Fault Locator
Product features
- Possibility damage-free location of impedance changes of tested cables and wires such as:
- shorted conductor,
- open conductor / end of cable – useful during the inventory of warehouses and stores,
- splice,
- splitter,
- water ingress,
- wet splice,
- bridge tap
- or other changes.
- Single measurement mode ONCE,
- Continuously measurement mode CONT,
- Tone signal generator TONE,
- Two cursors to mark two places of damage along with an indication of the distance between them,
- Built-in HELP function for easier interpretation of the reflectogram,
- 11 available measuring ranges from 7 m to 6000 m,
- „dead zone” limited to 0.6 m,
- Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
- manually set of sensitivity in 8 steps GAIN,
- output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
- Velocity of Propagation set in range from 10% to 99%,
- tight and durable housing with IP67 ingress protection degree.
- Small size and weight.
SKU: n/a - Possibility damage-free location of impedance changes of tested cables and wires such as:
-
Clamp Meters
TITAN Clamp Multimeter TN88A in Pakistan
Specifications:
- TITAN TN88A Digital Clamp Meter 500V Insulation Tester
- DC voltage: 1000V ± (0.8% + 2)
- AC voltage: 750V ± (1.2% + 4)
- Alternating current: 200A / 1000A ± (2.5% + 5)
- Resistance: 200Ω / 20kΩ ± (1.0% + 2)
- Insulation test 100kΩ to 2000MΩ (with option 500V insulation tester unit)
- High Resistance: 20MΩ / 2000MΩ ± (5.0% + 2)
- The continuity of the alarm
- Low screen voltage
- Data retention
- Input impedance: 10MΩ
- Sampling rate: 3 times / s
- Maximum display: 1999
- Jaw opening: 50mm
SKU: n/a
There are no reviews yet.