- Insulation resistance measurement:
- selectable measurement voltage in the 100…2500 V range with 100 V step,
- continuous indication of insulation resistance or leakage current,
- automatic discharge of capacitance of tested object after the insulation resistance measurement,
- acoustic signalling of five-second periods to facilitate obtaining time characteristics,
- measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s,
- indication of actual test voltage during the measurement,
- protection against measuring live objects,
- two and three-lead measurement method,
- Continuity measurement of protective and equipotential conductors according to EN 61557-4
- with the >200 mA current.
- Leakage current measurement.
- Measurement of alternating and direct voltages in the 0…750 V range.
- Built-in rechargeable battery pack.
- The instruments meet the requirements of the EN 61557 standard.
- The ability to charge from car lighter (12 V) socket (additional accessories).
MIC-2501,2500V Insulation Resistance Meter
1 in stock
Electrical safety:
- type of insulation: double, in acc. with EN 61010-1 und IEC 61557
- measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
- case protection rating in acc. with EN 60529: IP65
Other technical specifications:
- power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
- weight of the meter: approx. 0,9 kg
- dimensions: 200 x 180 x 77 mm
- display: LCD segment display
- measurement results memory: 990 cells, 11880 records,
- transmission of measurement results: USB
₨0
1 in stock
CompareWeight | 0.9 kg |
---|---|
Dimensions | 20 × 18 × 8 cm |
Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557-2 for RISOmin=UISOnom/IISOmax…1 TΩ (IISOmax=1 mA)
Range | Resolution | Accuracy |
---|---|---|
0,0…999,9 kΩ | 0,1 kΩ | ±(3% m.v. + 20 digits) |
1,000…9,999 MΩ | 0,001 MΩ | ±(3% m.v. + 20 digits) |
10,00…99,99 MΩ | 0,01 MΩ | ±(3% m.v. + 20 digits) |
100,0…999,9 MΩ | 0,1 MΩ | ±(3% m.v. + 20 digits) |
1,000…9,999 GΩ | 0,001 GΩ | ±(3% m.v. + 20 digits) |
10,00…99,99 GΩ | 0,01 GΩ | ±(3% m.v. + 20 digits) |
100,0…999,9 GΩ | 0,1 GΩ | ±(3% m.v. + 20 digits) |
Values of measured resistance depending on measurement voltage
Voltage UISO | Measurement range |
---|---|
100 V | 50 GΩ |
200…400 V | 100 GΩ |
500…900 V | 250 GΩ |
1000…2400 V | 500 GΩ |
2500 V | 1000 GΩ |
Continuity measurement of protective connections and equipotential bonding with 200 mA current.
Measurement range acc. to EN 61557-4: 0,10…999 Ω
Range | Resolution | Accuracy |
---|---|---|
0,00…19,99 Ω | 0,01 Ω | ±(2% m.v. + 3 digits) |
20,0…199,9 Ω | 0,1 Ω | ±(2% m.v. + 3 digits) |
200…999 Ω | 1 Ω | ±(4% m.v. + 3 digits) |
- Voltage on open terminals: 4…24 V
- Output current at R <2 Ω: ISC >200 mA
- Compensation of test lead resistance
- Current flowing in both directions, mean value of resistance is displayed
DC and AC voltage measurement
Range | Resolution | Accuracy |
---|---|---|
0…299,9 V | 0,1 V | ±(3% m.v. + 2 digits) |
300…750 V | 1 V | ±(3% m.v. + 2 digits) |
- Frequency range: 45…65 Hz
The acronym “m.v.” stands for a “measured reference value”.
Based on 0 reviews
Be the first to review “MIC-2501,2500V Insulation Resistance Meter”
-
Power Quality Analyzer
UT285C Three Phase Power Quality Analyzer
1. Waveform real-time display (4 channels voltage/4 channels current).
2. True RMS values of voltages and currents3. Peak current and voltage values4. Total harmonic distortion (THD)5. Active, reactive, apparent power, by phase and cumulative6. Transformer K factor7. Power factors (PF) and displacement factors (DPF or COSΦ)8. Short-term voltage flicker (PST)9. Three phase unbalance(current and voltage)10. USB interface/PC softwareSKU: n/a -
Oscilloscopes
UNI-T 2 Channel UPO2102E Ultra Phosphor Oscilloscope
- 100MHz bandwidth
- number of channels 2
- sampling 1GS / s
- max memory depth 56Mpts (per channel) (previously 28Mpts per channel)
- waveforms per second up to 80,000 wfms/s (formerly 50,000 wfms/s)
- time base range 5ns/div – 50s/div
- input coupling (1MΩ ± 2%) // (20pF ± 3pF)
- verical axis 1mV/div – 20V/div (1MΩ)
- DC gain accuracy ± 3%
- number of saved waveforms 65000
- trigger : Edge, Window, Runt, Time Out, Nth Edge, Delay, Duration, Setup / Hold, Pulse Width, Slope, Video, Pattern, RS232 / UART, I2C, SPI
- mathematical operations with waveforms : A + B, A-B, AxB, A / B, FFT, Logic operation, Editable Advanced, Filter
- automatic Measurement : Max, Min, High, Low, Middle, Pk-Pk, Ample, Mean, Cycle Mean, RMS, Cycle RMS, Cycle Area, OverShoot, PreShoot, Period, Freq, Rise, Fall, + Width, -Width, + Duty, -Duty, RiseDelay, FallDelay, Phase, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF
- number of measurements : 5 simultaneous measurements
- statistics : Mean, Max, Min, standard deviation, number of measurements
- frequency counter : 6 bits
- standard interfaces : USB-Host, USB-Device, LAN, AUX (Trig Out, Pass / Fail)
SKU: n/a -
Environment Meters
UT361 Anemoscopes
UT360 series anemograph is a professional anemograph used to measure wind temperature, wind speed and wind capacity, which is of stable performance, reliable and of neoteric appearance. The device can be widely used in the fields such as environmental protection, labor hygiene, industrial enterprise, scientific research. It is applied to environmental noise measurement, machinery equipment noise and architectural acoustics measurement.