MIC-2501,2500V Insulation Resistance Meter

Availability:

1 in stock


 

Electrical safety:

  • type of insulation: double, in acc. with EN 61010-1 und IEC 61557
  • measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
  • case protection rating in acc. with EN 60529: IP65

Other technical specifications:

  • power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
  • weight of the meter: approx. 0,9 kg
  • dimensions: 200 x 180 x 77 mm
  • display: LCD segment display
  • measurement results memory: 990 cells, 11880 records,
  • transmission of measurement results: USB

0

1 in stock

Compare
  • Insulation resistance measurement:
    • selectable measurement voltage in the 100…2500 V range with 100 V step,
    • continuous indication of insulation resistance or leakage current,
    • automatic discharge of capacitance of tested object after the insulation resistance measurement,
    • acoustic signalling of five-second periods to facilitate obtaining time characteristics,
    • measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s,
    • indication of actual test voltage during the measurement,
    • protection against measuring live objects,
    • two and three-lead measurement method,
  • Continuity measurement of protective and equipotential conductors according to EN 61557-4
  • with the >200 mA current.
  • Leakage current measurement.
  • Measurement of alternating and direct voltages in the 0…750 V range.
  • Built-in rechargeable battery pack.
  • The instruments meet the requirements of the EN 61557 standard.
  • The ability to charge from car lighter (12 V) socket (additional accessories).
Category:
Weight 0.9 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557-2 for RISOmin=UISOnom/IISOmax…1 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0,0…999,9 kΩ 0,1 kΩ ±(3% m.v. + 20 digits)
1,000…9,999 MΩ 0,001 MΩ ±(3% m.v. + 20 digits)
10,00…99,99 MΩ 0,01 MΩ ±(3% m.v. + 20 digits)
100,0…999,9 MΩ 0,1 MΩ ±(3% m.v. + 20 digits)
1,000…9,999 GΩ 0,001 GΩ ±(3% m.v. + 20 digits)
10,00…99,99 GΩ 0,01 GΩ ±(3% m.v. + 20 digits)
100,0…999,9 GΩ 0,1 GΩ ±(3% m.v. + 20 digits)

Values of measured resistance depending on measurement voltage

 

Voltage UISO Measurement range
100 V 50 GΩ
200…400 V 100 GΩ
500…900 V 250 GΩ
1000…2400 V 500 GΩ
2500 V 1000 GΩ

Continuity measurement of protective connections and equipotential bonding with 200 mA current.
Measurement range acc. to EN 61557-4: 0,10…999 Ω

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω ±(2% m.v. + 3 digits)
200…999 Ω 1 Ω ±(4% m.v. + 3 digits)
  • Voltage on open terminals: 4…24 V
  • Output current at R <2 Ω: ISC >200 mA
  • Compensation of test lead resistance
  • Current flowing in both directions, mean value of resistance is displayed

DC and AC voltage measurement

Range Resolution Accuracy
0…299,9 V 0,1 V ±(3% m.v. + 2 digits)
300…750 V 1 V ±(3% m.v. + 2 digits)
  • Frequency range: 45…65 Hz

The acronym “m.v.” stands for a “measured reference value”.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-2501,2500V Insulation Resistance Meter”

There are no reviews yet.

  • UT312 Vibration Tester

    0 out of 5
    (0)

    1. Highly accurate and precise

    2. Measures acceleration, velocity, displacement
    3. Can select different vibration frequency characteristics
    4. Auto power off, low battery indication
    5. Data hold
    SKU: n/a
  • LKZ-1000 Wires and pipe locator

    0 out of 5
    (0)
    • Passive or active modes of tracing.
    • Detection of underground live wires.
    • Detection of underground wires with no voltage (radio mode).
    • Detection of underground wires with no voltage using a transmitter (galvanised, inductive or clamp-based connection).
    • Tracing metallic or non-conductive pipes using an additional probe.
    • Tracing non-conductive pipelines using a “floating” probe.
    • Tracing a determined cable.
    • Determining the depth of a cable.
    SKU: n/a
  • YH 950 IRON FOR YH 950

    0 out of 5
    (0)
    SKU: n/a
  • UT222 2500A ACA DCA Digital Clamp Meters

    0 out of 5
    (0)

    UT222 are stable and safe 3 5/6 digit AC&DC digital clamp meters.It is perfectly designed with over-load protection for all ranges and the unique structure, making it a superb professional meter especially for electricians.
    An ideal tool for the maintenance and troubleshooting needed in metallurgy, manufacturing, petroleum, electric power, chemical industry, etc;

    SKU: n/a
  • CLAMP METER AC BM 5268

    0 out of 5
    (0)
    BM5268 AC Digital Clamp meter Technical parameters
    Functions Range Accuracy
    BM5268
      DC  Voltage   400mV/4V/40V/400V/600V ±(0.8%+2)
      AC  Voltage   4/40/400/600V ±(1.2%+5)
      AC  Current   4/40/400/600A ±(2%+10)
      Ω  Resistance   400/4K/40K/400K/4M/40MΩ ±(1%+3)
      Capacitance   10n/100n/1μ/10μ/100μ/1m/10mF ±(3%+5)
       Frequency   10/100/1K/10K/100K/1M/30MHz ±(0.5%+3)
       ºC/ºF   -50ºC~1000ºC ±(1%+5)
       -58ºF~1832ºF ±(1.2%+6)
      Functions Range Accuracy
      True RMS
      Manual range
      Automatic range
      Auto power OFF About  10minutes
    Auto power OFF/Manually turn it off
      Diode Test
      VHZ      voltage measuring frequency
    Phase line recognition
      Continuity Testing
      Data hold
      INR Surge voltage
      low Battery indication
      Overload protection
    Greatest display 1999
      Jaw Size Φ30mm
            General Features
      Power                                     DC9V(6F22)Battery
      Color Gray+Red
      Weight About 220g
     Size 195×64×35mm
      Standard accessories Multimeter leads+Batteries+Temperature Sensor
      Standard Pack Color Box,User Manua
      Safety rating EN61010-1,CAT.II 600V

     

     

    SKU: n/a