MIC-5001, 5000V Insulation Tester

Availability:

5 in stock


Insulation resistance measurement in a compact, light-weight, low-cost design.

  • Measurement to 5 TΩ
  • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
  • Continuous indication of insulation resistance or leakage current
  • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
  • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
  • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
  • Continuous display of test voltage during the measurement
  • Protection against measuring live objects
  • Two and three-lead measurement method
  • Ramp Test Insulation resistance measurement
  • Measurement of breakdown voltage with increments up to 1 kV / s
  • Measurement of alternating and direct voltages from 0 V to 750 V
  • 990 cells of memory (11880 records) to record results
  • Data transfer to PC via USB cable
  • Built-in rechargeable battery pack
  • Meets the requirements of the EN 61557 standard
  • Charge from optional car lighter (12 V) socket accessory

0

5 in stock

Compare

Insulation Resistance Meter

Category:
Weight 1 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557- 2 for RISOmin=VISOnom/IISOmax…5 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(3% m.v. + 20 digits)
1.000 to 5.000 TΩ 1 GΩ ±(4% m.v. + 50 digits)

Values of measured resistance depending on measurement voltage

Voltage VISO Measurement range
up to 100 V 50 GΩ
200 to 400 V 100 GΩ
500 to 900 V 250 GΩ
1000 to 2400 V 500 GΩ
2500 V 2500 GΩ
5000 V 5 TΩ

RampTest Insulation resistance measurement

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(5% m.v. + 40 digits)
1.000 to 4.999 TΩ 0.001 TΩ ±(5% m.v. + 40 digits)

The measurement of breakdown voltage in RampTest mode

Range Resolution Chosen UISO Accuracy
25.0 V to 99.0 V 0.1 V <600 V ± 5% m.v. ± 10 digits
100 V to 600 V 1 V <600 V ± 5% m.v. ± 4 digits
25 V to 999 V 1 V >600 V ± 5% m.v. ± 5 digits
1.00 kV to 5.00 kV 10V >600 V ± 5% m.v. ± 4 digits

DC and AC voltage measurement

Range Resolution Accuracy
0 to 299.9 V 0.1 V ±(3% m.v. + 2 digits)
300 to 750 V 1 V ±(3% m.v. + 2 digits)
  • frequency range: 45 to 65 Hz

VISO – measurement voltage
The acronym “m.v.” stands for a “measured reference value”

Electrical safety:

  • type of insulation double, in acc. with EN 61010-1 and IEC 61557
  • measurement category III 600 V (IV 300 V) in acc. EN 61010-1
  • case protection rating in acc. EN 60529 IP6529: IP65

Other technical specifications::

  • power supply of the meter NiMH 9.6 V – 2 Ah battery pack and power supply 12 V
  • weight of the meter approx. 0.9 kg, 2 lbs
  • dimensions 200 x 180 x 77 mm, 7.9 x 7 x 3 ins
  • LCD segment display
  • memory for measurement results:  990 cells, 11880 records
  • transfer of measurement results data via USB

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-5001, 5000V Insulation Tester”

There are no reviews yet.

  • ET 8133 DMM

    0 out of 5
    (0)

    Product description

    3 times/second
    Diode: YES
    Capacitance: YES
    True RMS: YES
    Data hold: YES
    Backlight: YES
    Flashlight: YES
    Auto power off: YES (no measurement operation within 15 minutes)
    Low battery indication: YES
    Environment temperature: 0~40℃, humidity <75%
    Storage environment: -20~60℃, humidity <80%
    DC voltage:
    Range: 200mV/2.000V/20.00V/200.0V/600V
    Resolution: 0.0001V/0.001V/0.01V/0.1V/1V
    Accuracy: ±(0.5%+3)
    Max.: 600V
    AC voltage:
    Range: 2.000V/20.00V/200.0V/600V
    Resolution: 0.001V/0.01V/0.1V/1V
    Accuracy: ±(1.0%+3)
    Max.: 600V
    Capacitance:
    Range: 20.00nF/200.0nF/2.000F/200.0F
    Resolution: 0.01nF/0.1nF/10nF/100nF
    Accuracy: ±5%+3
    Max.: 200μF
    AC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA/2A: ±(1.0%+3)
    10A: ±(1.5%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    DC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA: ±(2.0%+4)
    2A: ±(1.0%+5)
    10A: ±(2.0%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    Resistance:
    Range: 2.000KΩ/20.00KΩ/200.0KΩ/2.000MΩ/20.00MΩ
    Resolution: 0.001KΩ/0.01KΩ/0.1KΩ/0.001MΩ/0.01MΩ
    Accuracy:
    2.000KΩ: ±(1.5%+3)
    20.00KΩ: ±(0.5%+3)
    200.0KΩ: ±(0.5%+3)
    2.000MΩ: ±(1.0%+3)
    20.00MΩ: ±(1.5%+3)
    Max.: 20MΩ
    Continuity: YES
    NCV: YES
    Frequency response in AC mode: 40Hz~1KHz
    LCD size: 45 * 25mm / 1.8 * 1.0in
    Item size: 124 * 65 * 26mm / 4.9 * 2.6 * 1.0in
    Item weight: 210g / 7.4ounce
    Package size: 140 * 100 * 40mm / 5.5 * 3.9 * 1.6in
    Package weight: 220g / 7.8ounce

    SKU: n/a
  • UT281E True RMS Flex Clamp

    0 out of 5
    (0)
    SKU: n/a
  • UT283A Single Phase Power Quality Analyzer

    0 out of 5
    (0)

    1. Trend/event capture

    2. Harmonics/inrush current measurement
    3. File management through USB interface
    4. Flick measure (PST/PLT values)
    5. User friendly interface
    6. Multimeter functions
    7. Scope functions including waveform display
    8. 3.5 inches 64K color TFT LCD display
    9. THD (Total Harmonic Distortion) function
    10.Long-term monitoring
    SKU: n/a
  • DM 6013 LC METER

    0 out of 5
    (0)

    Features Of Handheld Mini Capacitor Meter Capacimeter DM6013L:

    • Automatic in zeroing and polar selection
    • Wide measuring range, covering 9 measuring sections from 0.1pF to 20,000uF
    • Max. display: 1999 counts(3 1/2digits)
    • Data Hold
    • LCD backlight
    • Two ways to test capacitance,input jack and meter pen,convenient to operate.
    SKU: 4000