MIC-5001, 5000V Insulation Tester

Availability:

5 in stock


Insulation resistance measurement in a compact, light-weight, low-cost design.

  • Measurement to 5 TΩ
  • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
  • Continuous indication of insulation resistance or leakage current
  • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
  • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
  • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
  • Continuous display of test voltage during the measurement
  • Protection against measuring live objects
  • Two and three-lead measurement method
  • Ramp Test Insulation resistance measurement
  • Measurement of breakdown voltage with increments up to 1 kV / s
  • Measurement of alternating and direct voltages from 0 V to 750 V
  • 990 cells of memory (11880 records) to record results
  • Data transfer to PC via USB cable
  • Built-in rechargeable battery pack
  • Meets the requirements of the EN 61557 standard
  • Charge from optional car lighter (12 V) socket accessory

0

5 in stock

Compare

Insulation Resistance Meter

Category:
Weight 1 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557- 2 for RISOmin=VISOnom/IISOmax…5 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(3% m.v. + 20 digits)
1.000 to 5.000 TΩ 1 GΩ ±(4% m.v. + 50 digits)

Values of measured resistance depending on measurement voltage

Voltage VISO Measurement range
up to 100 V 50 GΩ
200 to 400 V 100 GΩ
500 to 900 V 250 GΩ
1000 to 2400 V 500 GΩ
2500 V 2500 GΩ
5000 V 5 TΩ

RampTest Insulation resistance measurement

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(5% m.v. + 40 digits)
1.000 to 4.999 TΩ 0.001 TΩ ±(5% m.v. + 40 digits)

The measurement of breakdown voltage in RampTest mode

Range Resolution Chosen UISO Accuracy
25.0 V to 99.0 V 0.1 V <600 V ± 5% m.v. ± 10 digits
100 V to 600 V 1 V <600 V ± 5% m.v. ± 4 digits
25 V to 999 V 1 V >600 V ± 5% m.v. ± 5 digits
1.00 kV to 5.00 kV 10V >600 V ± 5% m.v. ± 4 digits

DC and AC voltage measurement

Range Resolution Accuracy
0 to 299.9 V 0.1 V ±(3% m.v. + 2 digits)
300 to 750 V 1 V ±(3% m.v. + 2 digits)
  • frequency range: 45 to 65 Hz

VISO – measurement voltage
The acronym “m.v.” stands for a “measured reference value”

Electrical safety:

  • type of insulation double, in acc. with EN 61010-1 and IEC 61557
  • measurement category III 600 V (IV 300 V) in acc. EN 61010-1
  • case protection rating in acc. EN 60529 IP6529: IP65

Other technical specifications::

  • power supply of the meter NiMH 9.6 V – 2 Ah battery pack and power supply 12 V
  • weight of the meter approx. 0.9 kg, 2 lbs
  • dimensions 200 x 180 x 77 mm, 7.9 x 7 x 3 ins
  • LCD segment display
  • memory for measurement results:  990 cells, 11880 records
  • transfer of measurement results data via USB

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-5001, 5000V Insulation Tester”

There are no reviews yet.

  • MIC-10 , 1000 V Insulation Tester

    0 out of 5
    (0)

    Insulation Resistance Meter

    SKU: n/a
  • JM X4 MAGNETIC WRIST BAND

    0 out of 5
    (0)
    SKU: n/a
  • TND 500VA

    0 out of 5
    (0)

    Input Voltage=140-250
    Output Voltage=220
    Copper Wind
    Analog Display
    Under and Over Volt Indication
    Under Volt Protection
    Dual Output Socket 110/220

    SKU: n/a
  • CLAMP METER AC BM 2000B

    0 out of 5
    (0)

    SPECIFICATIONS:

    – Maximum display: 1999
    – Method indication: LCD
    – Maximum arm span: 60mm
    – Operating temperature range:
    work: 0C – 40C
    Storage:-10C – 60C
    – Power supply: 9V battery
    – Low battery indication: YES, graphic symbol
    – Audible indication: YES, piezoelectric transducer
    – Dimensions: 270x100x45 mm
    – Weight: about 610g (with battery)

    Features
    – Measuring voltage: 0-1000V 2 range
    – Measurement of AC voltage: 0-700V in 1 range
    – Measurement of alternating current: 200A-2000A in 2 ranges
    – Measuring current: 200A-2000A in 2 ranges
    – Measurement of resistance: 2k in 1 range
    – Measuring capacity: NO
    – Frequency: NO
    – Temperature measurement: NO
    – Testing LEDs: YES
    – Acoustic continuity tester: YES
    – Distance between arms: 6cm
    – Meter dimensions: 270x100x45 mm
    – Weight: 610g with battery
    – Basic accuracy: ± (0.5% +2 digits)

    Packages Include:

    1 × Clamp-On Meter BM-2000B

    An internal link is any link from one page on your website to another page on your website. Both your users and search engines use links to find content on your website. Your users use links to navigate through your site and to find the content they want to find. Search engines also use links to navigate your site. They won’t find a page if there are no links to it. There are several types of internal links. In addition to links on your homepage,mean post feed, etc, you can also add links within your content. We call those contextual links. Contextual links point your users to interesting and related content.
    SKU: n/a
  • UT12M-US AC Voltage Detector

    0 out of 5
    (0)

    features:
    1. Auto power off
    2. Buzzer
    3. LED indication
    4. IP 67
    5. AC voltagedetection
    6. High/Lowvoltage mode
    7. Magnetic solenoiddetection

    Applications:
    Low voltage mode: Low-voltage motor (<90V), audio systems, arc welding machines,underground mining lighting, cables with thick insulation layer and other weakelectromagnetic AC signals.
    High voltage mode: Urban electric supply and three-phase systems (90~1000V). Forexample, power distribution units, electrical panels, electrical appliances.

    SKU: n/a
  • JM OP018 OPENING TOOL

    0 out of 5
    (0)
    SKU: n/a