MRU-10 Earth Resistance Meter

Availability:

3 in stock


It allows to:

  • measure earthing resistance using auxiliary electrodes,
  • measurement of resistance of auxiliary electrodes RS and RH,
  • measurement of interference voltage,
  • measurement in the presence of interference voltage in the power network with frequency 50 Hz and 60 Hz,
  • selection of maximum measuring voltage (25 V and 50 V),
  • indication of battery state.

0

3 in stock

Compare

MRU-10 is a simple meter that allows you to measure grounding by the use of the technical method and to measure grounding resistance by the use of the 2-pole method. The instrument is easy to handle, resistive to interference, and highly accurate. MRU-10  is a basic device that allows checking the quality of the grounding system on the basis of the received measurement result. Its ergonomic shape, durable and firm housing, as well as big and clear display make this instrument ideal to use both in the field and most working environments. The device is simple to operate and intuitive. It is the best choice for electrical installations contractors, technicians, and professionals dealing with grounding measurements.

Weight 1 kg
Dimensions 22 × 10 × 6 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of earthing resistance (method 3-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (for 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.
  • measurement current: under short circuit >20 mA,
  • voltage on open terminals: selectable 25 V AC or 50 V AC,
  • frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz),
  • selection of measuring frequency in settings.

Measurement of earthing resistance (method 2-pole)

Range Resolution Accuracy
0,01…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

Measurement of earthing resistance (method 2-pole) RH and RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±8% m.v.
1,00…9,99 kΩ 0,01 Ω
10,0…19,9 kΩ 0,1 Ω

Electric security:

  • type of insulation: double, according to EN 61010-1 and IEC 61557,
  • measurement category: CAT IV 150 V acc. to EN 61010-1,
  • protection class acc. to EN 60529: IP67.

Rated operational conditions:

  • operation temperature: -10…+50°C,
  • storage temperature: -20…+60°C,
  • humidity: 20…90%.

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 221 x 102 x 62 mm,
  • number of measurements (RE3P) carried out of set of batteries: > 3000

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-10 Earth Resistance Meter”

There are no reviews yet.

  • JM OP017 OPENING TOOL

    0 out of 5
    (0)
    SKU: n/a
  • UT383-BT Mini Light Meter

    0 out of 5
    (0)
    SKU: n/a
  • UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • RF-0.7X New

    0 out of 5
    (0)
    SKU: n/a
  • LM 320A Angle Meters

    0 out of 5
    (0)

    Features of LM320 Series Angle Meters

    Certificates: CE, UKCA

    ● Relative / absolute measurement
    ● 360°comprehensive measurement
    ● Data hold

    ● Portable and lightweight
    ● Unique laser design

    SKU: n/a
  • Titan Digital Clamp Meter Multimeter Ampere Meter

    0 out of 5
    (0)

    3 1/2 digits LCD with a Max. Reading of 1999

    2) Diode and Buzzer function

    3) Low battery indication

    4) Overload protection

    5) Data hold for easy reading

    * Specification:

    1) DC voltage: 600V (?1.0%)

    2) AC voltage: 450V ( ?1.2% )

    3) OHM: 200K? (?1.0%)

    4) ACA: 20-400A (?2.0%)

    5) Power supply: (AAA) 1.5V?2

    6) Data hold: YES

    7) Dimension 150L?63W?27.5Hmm

    Weight 121g

    SKU: n/a