MRU-30 Earth Resistance and Resistivity Meter

Availability:

3 in stock


 

  • It allows to take the measurements of:

    • earthing resistance using auxiliary electrodes,
    • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
    • earthing resistance using double clamps for measuring multiple earthing without underground connections.
    • ground resistivity (Wenner method),
    • continuity of equipotential bondings and protective
    • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

    Additionally:

    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network
    • with frequency 50Hz, 60Hz,
    • selection of maximum measuring voltage (25V and 50V),
    • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
    • memory of 990 measurements (10 banks of 99 cells each),
    • calibration of clamp used,
    • data transmission to the computer (USB),
    • indication of battery state.

0

3 in stock

Compare

The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3-pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can’t be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages.

  • Robust and weatherproof (IP65) – no ingress of dust, water protected by a nozzle against enclosure from any direction.
  • Ergonomic casing – small and handy casing to make the measurements more convenient than before.
  • Built-in rechargeable battery – saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket!
  • Clear on-screen notes – displayed on screen before and after the measurement to alert user of possible dangers and irregularities.
  • Many measurement methods available in a small, portable casing
Weight 5 kg
Dimensions 20 × 15 × 7 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of continuity of equipotential bondings and protective conductors (Rcont)
measurement range to IEC 61557-4:2007: 0,13 Ω…1999 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…1999 Ω 1 Ω

• measurement current: under short circuit >200mA
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)

Measurement of earthing resistance (method 3- and 4-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (dla 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable 25 V AC or 50 V AC,
• frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz).

Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• voltage on open terminals: selectable 25 V AC or 50 V AC,
• measurement current: under short circuit >20 mA,
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)
Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% m.v.+ 8 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…19,9 kΩ 0,1 kΩ

 

Measurement of multiple earthing resistance with using double clamps

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits)
20,0…99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits)

• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz
(for networks 60 Hz)

Measurement of ground resistivity 
Measurement method: Wenner, ρ=2πLRE

Range Resolution Accuracy
0,00…9,99 Ωm 0,01 Ωm depending on measurement
accuracy RE with 4p method,
but not less than ±1 digit
10,0…99,9 Ωm 0,1 Ωm
100…999 Ωm 1 Ωm
1,00…9,99 kΩm 0,01 kΩm
10,0…99,9 kΩm 0,1 kΩm
100…999 kΩm 1 kΩm

L – distance between probes: 1…50 m.. or 1…150 ft

Electric security:

  • type of insulation: double, according to EN 61010-1 i IEC 61557,
  • measurement category: CAT III 300V wg EN 61010-1,
  • protection class acc. to EN 60529: IP65,

Rated operational conditions:

  • operation temperature: -10…+55°C,
  • storage temperature: -20…+80°C,
  • humidity: 20…90%,

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 200x150x74 mm.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-30 Earth Resistance and Resistivity Meter”

There are no reviews yet.

  • ET 8102 DMM

    0 out of 5
    (0)

    Specifications:
    Model:ET8102
    Display:5999 Counts
    Color:Black
    DC Voltage:6V/60V/600V±(0.5%+3),1000V±(0.8%+10)
    AC Voltage:6V/60V/600V±(0.8%+3),750V±(1.2%+10)
    DC Current:600uA/6000uA/60mA/600mA±(1.2%+10),6A/10A±(2.0%+30)
    AC Current:600uA/6000uA/60mA/600mA±(1.2%+10),6A/10A±(2.0%+30)
    Resistance:600Ω±(0.8%+5),6KΩ/60KΩ/600KΩ/6MΩ±(0.8%+3),40MΩ±(2.5%+3)
    Capacitance:60nF/600nF/6μF/60μF/600μF±(3.5%+20),6mF/30mF±(5.0%+3)
    Frequency:10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz±(0.1%+3)
    Temperature:-20℃~1000℃,±(1.0%+5)<400℃,±(1.5%+15)≥400℃
    0℉~1832℉,±(0.75%+5)<750℉,±(1.5%+15)≥750℃
    NCV test:Yes
    Zero line/fire wire:Yes
    Duty cycle:Yes
    Diode test:Yes
    Continuity testing:Yes
    Backlight:Yes
    Date hold:Yes
    True RMS:Yes
    Max/Min value measurement:Yes
    Flashlight:Yes
    Auto power off:Yes
    Low battery indication:Yes
    Over range indication:Yes
    Power:2 x 1.5V AAA Battery (not included)
    Product Size:142 x 68 x 32 mm
    Product Net Weight:187g

    Package Information:
    Package Size:16.5 x 10 x 5cm / 6.5 x 3.9 x 2in
    Package Weight:295g / 10.4 oz

    Package list:
    1 x Digital Multimeter
    2 x Test Leads Pens
    1 x User Manual
    • 1.Multifunction:Can measure AC/DC voltage,AC/DC current,resistance,capacitance,
    • 2.Portable design:Small and can be put into pocket,easy to carry.
    • 3.Wide range of applications:It’s a perfect tool for the laboratory,factory and home.
    • 4.Easy to use & clear to read:With large LCD backlight display and flashlight function,convenient to read data in dark.
    • frequency,duty cycle,temperature,NCV,diode,continuity,zero line/fire wire.

    SKU: n/a
  • UTi165A Thermal Imager UNI-T

    0 out of 5
    (0)
    Specifications
    Model UTi165A
    IR resolution 160×120 pixels
    Field of view (FOV) 56°×42°
    Thermal sensitivity (NETD) ≤150mk (0.15℃)
    Temperature range  -10~400℃
    Spatial resolution (IFOV) 11mrad
    Frame rate <9Hz
    Measurement accuracy ±2℃ or ±2% whichever is greater
    Focus Focus free
    Display modes Thermal
    Display 2.8”LCD
    Auto capture of Hi/Lotemperature
    Measurement modes
    WIFI
    PC analysis software
    Drop proof 2m
    IP rating IP65
    General Characteristics
    Power Li-ion battery (3.7V 5000mAh)
    Product color Red and grey
    Product net weight 455g
    Product size 236mm x 75.5 mm x 86mm
    Standard accessories micro USB cable, micro SD card, Type-C USB cable
    Standard individual packing Blister, gift box, English manual
    Standard quantity per carton 5pcs
    Standard carton measurement 650mm x 355 mm x 180mm
    Standard carton gross weight About 5kg
    SKU: n/a
  • UT243 Power and Harmonics Clamp Meters

    0 out of 5
    (0)

    UT240 series is a stable, safe and reliable handheld power and harmonics clamp meter, which combines with digital ammeter, power measurement, harmonic measurement and equipped with a powerful measurement and data processing software. It is suitable for testing, calculating and displaying voltage, current, active power, power factor, phase angle, apparent power, reactive power, harmonic, electrical energy and frequency etc. Its harmonic measurement can be measured up to 20 times.

    SKU: n/a
  • UT216A 600A Digital Clamp Meters

    0 out of 5
    (0)

    UT216 series true RMS digital clamp meter is a new-generation practical electrotechnical measurement meter which has the features of high reliability, high safety, automatic range and handheld type, has full-range overload protection and unique appearance design, is more excellent in performance, and is an ideal tool for detection, maintenance and repair of various universities and colleges, smelting, communication, manufacturing, petroleum, national defense, electrical, power and circuit equipment.
    UTD216A (main features)

    • 1、600A AC current measurement
    • 2、True RMS response for ACV and ACA
    • 3、99.99mF capacitance measurement
    • 4、Non-contact voltage detection with LED indication
    • 5、Flashlight for working at dark environment
    SKU: n/a