MRU-30 Earth Resistance and Resistivity Meter

Availability:

3 in stock


 

  • It allows to take the measurements of:

    • earthing resistance using auxiliary electrodes,
    • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
    • earthing resistance using double clamps for measuring multiple earthing without underground connections.
    • ground resistivity (Wenner method),
    • continuity of equipotential bondings and protective
    • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

    Additionally:

    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network
    • with frequency 50Hz, 60Hz,
    • selection of maximum measuring voltage (25V and 50V),
    • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
    • memory of 990 measurements (10 banks of 99 cells each),
    • calibration of clamp used,
    • data transmission to the computer (USB),
    • indication of battery state.

0

3 in stock

Compare

The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3-pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can’t be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages.

  • Robust and weatherproof (IP65) – no ingress of dust, water protected by a nozzle against enclosure from any direction.
  • Ergonomic casing – small and handy casing to make the measurements more convenient than before.
  • Built-in rechargeable battery – saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket!
  • Clear on-screen notes – displayed on screen before and after the measurement to alert user of possible dangers and irregularities.
  • Many measurement methods available in a small, portable casing
Weight 5 kg
Dimensions 20 × 15 × 7 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of continuity of equipotential bondings and protective conductors (Rcont)
measurement range to IEC 61557-4:2007: 0,13 Ω…1999 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…1999 Ω 1 Ω

• measurement current: under short circuit >200mA
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)

Measurement of earthing resistance (method 3- and 4-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (dla 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable 25 V AC or 50 V AC,
• frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz).

Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• voltage on open terminals: selectable 25 V AC or 50 V AC,
• measurement current: under short circuit >20 mA,
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)
Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% m.v.+ 8 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…19,9 kΩ 0,1 kΩ

 

Measurement of multiple earthing resistance with using double clamps

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits)
20,0…99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits)

• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz
(for networks 60 Hz)

Measurement of ground resistivity 
Measurement method: Wenner, ρ=2πLRE

Range Resolution Accuracy
0,00…9,99 Ωm 0,01 Ωm depending on measurement
accuracy RE with 4p method,
but not less than ±1 digit
10,0…99,9 Ωm 0,1 Ωm
100…999 Ωm 1 Ωm
1,00…9,99 kΩm 0,01 kΩm
10,0…99,9 kΩm 0,1 kΩm
100…999 kΩm 1 kΩm

L – distance between probes: 1…50 m.. or 1…150 ft

Electric security:

  • type of insulation: double, according to EN 61010-1 i IEC 61557,
  • measurement category: CAT III 300V wg EN 61010-1,
  • protection class acc. to EN 60529: IP65,

Rated operational conditions:

  • operation temperature: -10…+55°C,
  • storage temperature: -20…+80°C,
  • humidity: 20…90%,

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 200x150x74 mm.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-30 Earth Resistance and Resistivity Meter”

There are no reviews yet.

  • TITAN TN 305DS DC Power Supply

    0 out of 5
    (0)

    Operating Conditions

    Supply power: AC 220-240V, 50Hz/60Hz.

    Working Temperature: -10°C ~ 40 °C

    Relative Humidity: ‹ 90%

    Storage Conditions: -10°C ~ 40 °C

    Relative Humidity: ‹ 80%

    Stable Voltage

    The output voltage is between 0 and nominal value continuously adjustable

    Voltage Stability: ≤0.01% +2mV

    Load Stability: ≤ 0.01% +2mV

    Recovery Time: ≤100µS

    Temperature Coefficient: ≤ 200PPM/°C

    Ripple Noise: ≤1 MVRMS(RMS)
    Stable Current

    Power Stability: 0.1% + 3mA

    Load Stability: 0.2% + 3mA

    Ripple Noise : ≤2mArms(RMS)

    The output current is between 0 and nominal value continuously adjustable

    SKU: n/a
  • YH Q208C PIPE FOR YH 8508D,

    0 out of 5
    (0)
    SKU: n/a
  • Mechanic Special Solder Paste XG-50 35G 183°C

    0 out of 5
    (0)

    This is solder paste for soldering small SMD components in a reflow oven or with a hot air soldering station. comes in a small container for prototyping or repairing job.This pack is the right amount of solder paste for most hobby projects. This paste is the replacement for solder wire used in Through-hole soldering, some times solder flux is referred to as solder paste.

    SKU: n/a
  • PQM-707 Power Quality Analyzer

    0 out of 5
    (0)
    • Features:

      • 7″ touch screen – intuitive operating
      • CAT IV 600V – high safety
      • all parameters acc. to class S – high accuracy of measurements
      • Li-Ion rechargeable battery – higher mobility
      • removable memory card – recording data with no restrictions

      Possible measurements:

      • Measurements according to EN 50160,
      • Voltage L1, L2, L3, N-PE (five inputs),
        – average, minimum, maximum values, range to 760 V, ability to work with voltage transformers,
      • Current L1, L2, L3, N (four inputs),
        – average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
      • Crest factor for voltage and current,
      • Frequency from 40 Hz to 70 Hz ,
      • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
      • Power recording:
        • Budeanu method,
        • IEEE 1459,
      • Active, reactive, apparent energy,
      • Power factor, cosφ, tgφ,
      • Up to 50th harmonics for voltage and current,
      • Total Harmonic Distortion (THD) for voltage and current,
      • Short-term (PST) and long-term (PLT) flicker,
      • Unbalance of voltage and current,
      • Current and voltage events registration including waveforms and RMS graphs half period,
      • Inrush current
      • Calculator of energy tariffs
      • ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
    SKU: n/a
  • Uni-T UT204 Auto-Ranging AC DC Ture RMS Auto/Manual Range Digital Handheld Clamp Meter Multimeter Test Tool

    0 out of 5
    (0)
    Specifications for this item
    Brand Name Uni-T
    Color UT204
    Ean 6902890900184 , 6934920395172 , 6955170801404
    External Testing Certification CE
    Included Components Bag
    Item Weight 9.2 ounces
    Maximum Current 400 amps
    Measurement System US
    Measurement Type Multimeter
    Model Number UT204
    Number of Items 20
    Part Number UT204
    Power Source Type Battery Powered
    Style UT204
    UNSPSC Code 41110000
    SKU: n/a