-12%

CMM-40 Industrial Multimeter

Availability:

5 in stock


The most important features of CMM-40 are:

  • autoranging/manual range selection,
  • „DATA HOLD” function, for holding measured values,
  • „REL” function, which allows you to make measurements relative to a stored reference value,
  • „MAX/MIN” function,
  • „PEAK HOLD” function,
  • memory for 2000 measurement resultS,
  • continuity test with acoustic signalling (beeper),
  • „AUTO-OFF” function,
  • display 4¾ digits (40000 max),
  • double molded, waterproof casing.

30,270 34,221

5 in stock

Compare

Industrial multimeter CMM-40 was designed for the purpose of measurements of AC/DC voltage, AC/DC current, resistance, capacitance, frequency (electrical and electronic), duty cycle, temperature and also for testing diodes and continuity.

Category:
Weight 0.4 kg
Dimensions 19 × 8 × 5 cm

Frequency measurement (electronic)

Range Resolution Accuracy
40,000 Hz 0,001 Hz ±(0,1% m.v. + 1 digit)
400,00 Hz 0,01 Hz
4,0000 kHz 0,0001 kHz
40,000 kHz 0,001 kHz
400,00 kHz 0,01 kHz
4,0000 MHz 0,0001 MHz
40,000 MHz 0,001 MHz
100,00 MHz 0,01 MHz not speccified
  • Sensitivity: 0.8 V rms min. @ 20% to 80% duty cycle and <100 kHz; 5 V rms min @ 20% to 80% duty cycle and > 100 kHz

Frequency measurement (electrical)

Range Resolution Accuracy
40,00 Hz…10,000 kHz 0,01 Hz…0,001 kHz ± 0,5% m.v.
  • sensitivity: 1 V rms

Duty cycle measurement

Range Resolution Accuracy
0,10…99,00% 0,01% ±(1,2% m.v. + 2 digits)
  • pulse width: 100μs – 100 ms,
  • frequency width: 5 Hz…150 kHz.

Temperature measurement

Range Resolution Accuracy
-50,0°C…+1200,0°C 0,1°C ±(1% m.v. + 2,5°C)
-58,0°F…+2192,0°F 0,1°F ±(1% m.v. + 4,5°F)

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,01 mV ±(0,06% m.v. + 4 digits)
4,0000 V 0,0001 V
40,000 V 0,001 V
400,00 V 0,01 V
1000,0 V 0,1 V ±(0,1% w.m. + 5 cyfr)

AC voltage measurement (True RMS)

Range Resolution Accuracy
400,00 mV 0,01 mV ±(1% m.v. + 40 digits)
4,0000 V 0,0001 V ±(1% m.v. + 30 digits)
40,000 V 0,001 V
400,00 V 0,01 V
1000,0 V 0,1 V
  • frequency range: 50…1000 Hz.

AC/DC current measurement (True RMS)

Range Resolution Accuracy
400,00 μA 0,01 μA dla DC ±(1,0% m.v. + 3 digits)

dla AC ±(1,5% m.v. + 30 digits)

4 000,0 μA 0,1 μA
40,000 mA 0,001 mA
400,00 mA 0,01 mA
10,000 A 0,001 A
  • 20 A: 30 sec max with reduced accuracy.

Resistance measurement

Range Resolution Accuracy
400,00 Ω 0,01 Ω ±(0,3% m.v. + 9 digits)
4,0000 kΩ 0,0001 kΩ ±(0,3% m.v. + 4 digits)
40,000 kΩ 0,001 kΩ
400,00 kΩ 0,01 kΩ
4,0000 MΩ 0,0001 MΩ
40,000 MΩ 0,001 MΩ ±(2,0% m.v. + 10 digits)

Capacitance measurement

Range Resolution Accuracy
40,000 nF 0,001 nF ±(3,5% m.v. + 40 digits)
400,00 nF 0,01 nF
4,0000 μF 0,0001 μF ±(3,5% m.v. + 10 digits)
40,000 μF 0,001 μF
400,00 μF 0,01 μF
4000,0 μF 0,1 μF ±(5% m.v. + 10 digits)
40,000 mF 0,001 mF

Other technical data:

  • power supply: 9 V battery type 6LR61
  • diode test: I=0,9 mA, U0 = 2,8 V DC
  • continuity test: I<0,35 mA, sound signal for R<35 Ω
  • over range indication: 0L displayed
  • crest factor: ≤ 3 at full scale up to 500 V; decreasing linearly to ≤ 1,5 at 1000 V
  • PEAK: captures peaks >1 ms
  • sampling rate: 2 times per second
  • input impedance: 10 MΩ (V DC), 9 MΩ (V AC)
  • display: 40000 counts backlit LCD with bargraph, 4¾ digits
  • store capacitance: 2000
  • dimensions: 187 x 81 x 55 mm
  • weight: 342 g
  • fuses: mA, µA range: 0,5 A/1000 V ceramic fast blow; A range: 10 A/1000 V ceramic fast blow
  • auto power OFF: 15 min.
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032

Electric security:

  • type of insulation: double, according to EN 61010 – 1 and IEC 61557
  • measurement category: CAT III 1000 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP67

Rated operational conditions:

  • operating temperature: 0…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 87°F (31°C); decreasing linearly to 50% at 104°F (40°C)
  • operating altitude: max 2000 m

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMM-40 Industrial Multimeter”

There are no reviews yet.

  • UT58B General Digital Multimeter

    0 out of 5
    (0)

    1. 2000 display count, refresh rate 2~3 times/s

    2. Function symbols and test lead connection indication
    3. Transistor measurement
    4. Temperature measurement mode, with K-type temperature probe
    5. Diode and continuity buzzer; auto power off; overload protection
    6. Data hold; 20A AC/DC current measurement
    SKU: n/a
  • CLAMP METER AC BM 528F

    0 out of 5
    (0)
    Product Description
    BM528F AC Digital Clamp meter Technical parameters
    Functions
    Range
    Accuracy

    (BM528F)
    DC Voltage
    200mV/2V/20V/200V/1000V
    ±(0.8%+2)
    AC Voltage
    2V/20V/200V/700V
    ±(1.2%+5)
    AC Current
    2A/20A/200A/600A
    ±(2%+10)
    Ω Resistance
    200/2K/20K/200K/2M/20MΩ
    ±(1%+3)
    Capacitance
    20n/200n/2μ/20μ/200μ/2mF
    ±(3%+5)
    Frequency
    200/2K/20K/200K/2M/20MHz
    ±(0.5%+3)
    ℃ / ℉
    -50℃ ~1000℃

    -58℉~1832℉

    ±(1%+5)

    ±(1.2%+6)
    SKU: n/a
  • UT60S

    0 out of 5
    (0)
    1. 9999 counts
    2. True RMS
    3. Bluetooth
    4. Duty cycle
    5. Diode/Continuity test
    6. Temperature
    7. Non-contact voltage
    8. Analog bar/Data hold
    9. Backlight/Relative mode
    10. Auto/Manual range
    11. Low battery indication
    12. Three-color LED light indicator
    SKU: n/a
  • EARTH TESTER KEW 4105A

    0 out of 5
    (0)

    • In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
    (unit can be hung from the neck for simplified measurement)
    • The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes.
    • Dust and drip proof. (designed to IEC 60529 IP54)
    • Earth resistance value can be read directly from the scale.
    • Designed to meet IEC 61010-1 safety standard.
    • Capable of measuring earth voltage.
    • Small and lightweight. Shock resistant new case material.
    • 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.

    SKU: n/a
  • UT12D-US AC Voltage Detector

    0 out of 5
    (0)

    features:
    1. Auto power off
    2. Buzzer
    3. LED indication
    4. AC voltagedetection
    5. High/Low voltagemode

    Applications:
    Low voltage mode: Low-voltage motor (<90V), audio systems, arc welding machines,underground mining lighting, cables with thick insulation layer and other weakelectromagnetic AC signals.
    High voltage mode: Urban electric supply and three-phase systems (90~1000V). Forexample, power distribution units, electrical panels, electrical appliances.

    SKU: n/a