UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope


Analog bandwidth 150MHz 250MHz
Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
Memory depth 70Mpts
Waveform capture rate 200,000wfms/s
Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
Input impedance (1MΩ±1%) II (20pF±3pF)
Input impedance digital (101kΩ±1%) II (9pF±1pF)
Vertical scale 1mV/div~20 V/div (1 MΩ)
DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
Waveform record 100,000 frames
Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRay
Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
 

 

Auto measurements

Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
Measurement display 5 types
Measurement statistics Average, Max, Min, standard deviation and number of measurements
Frequency counter 6 bits
Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
 

 

Standard Accessories

USB interface cable UT-D14
Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
16CH Logic analyzer probe UT-15M

 

366,000 370,980

Compare

UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope

Mixed Signal Oscilloscope is based on UNI-T’s unique Ultra Phosphor technology. A multifunctional, high-performance oscilloscope that is easy to use, with excellent technical specifications, and a perfect combination of many functionalities that help users to quickly complete testing.

Category:

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope”

There are no reviews yet.

  • MECHANIC lead-free ESD soldering tip 900M-T-K

    0 out of 5
    (0)

    MECHANIC lead-free ESD soldering tip 900M-T-K

    High precision, no oxygen copper, anti-static, long service life

    SKU: n/a
  • ET 8133 DMM

    0 out of 5
    (0)

    Product description

    3 times/second
    Diode: YES
    Capacitance: YES
    True RMS: YES
    Data hold: YES
    Backlight: YES
    Flashlight: YES
    Auto power off: YES (no measurement operation within 15 minutes)
    Low battery indication: YES
    Environment temperature: 0~40℃, humidity <75%
    Storage environment: -20~60℃, humidity <80%
    DC voltage:
    Range: 200mV/2.000V/20.00V/200.0V/600V
    Resolution: 0.0001V/0.001V/0.01V/0.1V/1V
    Accuracy: ±(0.5%+3)
    Max.: 600V
    AC voltage:
    Range: 2.000V/20.00V/200.0V/600V
    Resolution: 0.001V/0.01V/0.1V/1V
    Accuracy: ±(1.0%+3)
    Max.: 600V
    Capacitance:
    Range: 20.00nF/200.0nF/2.000F/200.0F
    Resolution: 0.01nF/0.1nF/10nF/100nF
    Accuracy: ±5%+3
    Max.: 200μF
    AC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA/2A: ±(1.0%+3)
    10A: ±(1.5%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    DC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA: ±(2.0%+4)
    2A: ±(1.0%+5)
    10A: ±(2.0%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    Resistance:
    Range: 2.000KΩ/20.00KΩ/200.0KΩ/2.000MΩ/20.00MΩ
    Resolution: 0.001KΩ/0.01KΩ/0.1KΩ/0.001MΩ/0.01MΩ
    Accuracy:
    2.000KΩ: ±(1.5%+3)
    20.00KΩ: ±(0.5%+3)
    200.0KΩ: ±(0.5%+3)
    2.000MΩ: ±(1.0%+3)
    20.00MΩ: ±(1.5%+3)
    Max.: 20MΩ
    Continuity: YES
    NCV: YES
    Frequency response in AC mode: 40Hz~1KHz
    LCD size: 45 * 25mm / 1.8 * 1.0in
    Item size: 124 * 65 * 26mm / 4.9 * 2.6 * 1.0in
    Item weight: 210g / 7.4ounce
    Package size: 140 * 100 * 40mm / 5.5 * 3.9 * 1.6in
    Package weight: 220g / 7.8ounce

    SKU: n/a
  • UT505B Handheld Insulation Resistance Tester

    0 out of 5
    (0)

    1. Auto power off

    2. LCD backlight
    3. High voltage output alarm
    4. 99-group data storage
    5. Data hold
    6. Meets IEC 61557:  61557-1:2007;  61557-2:2007;  61557-4:2007
    SKU: n/a
  • Clamp Meter BM 820A

    0 out of 5
    (0)

    ACA
    ACV/DCV
    RESISTANCE
    DATA HOLD
    LARGE LCD DISPLAY

    SKU: n/a