Multimeters
UT136B+ Digital Multimeter
Availability:
20 in stock
1. Measures up to 1000V and 10A AC/DC voltage and current
2. Equipped with 3mm protective sleeve; 2 meters drop proof
3. Large LCD display; Overload alarm
4. Quick sampling rate, up to 4 times/s
5. Quick capacitor measurement (measures 1mF in 4 seconds)
6. Low power consumption and auto power saving function; long battery service life (>500hrs)
₨5,700 ₨5,900
20 in stock
CompareThe new generation of UT136+ series digital multimeter has an innovative industrial design which ensures that the product can withstand a drop of 2 meters height. Large LCD screen provides a clear display and its 4 times/second sampling rate provides users with more accurate readings. UT136+ series is designed to work safely in CAT II1000V/CAT III 600V environment.
Applications:
This series is suitable for civil/commercial use such as HVAC technicians and electricians.
Weight | 0.3 kg |
---|---|
Dimensions | 17 × 8 × 5 cm |
Specifications | Range | UT136B+ |
DC voltage (V) | 1000V | ±(0.7%+3) |
AC voltage (V) | 1000V | ±(1%+3) |
DC current (A) | 10A | ±(1%+3) |
AC current (A) | 10A | ±(1.2%+5) |
Resistance (Ω) | 40MΩ | ±(0.8%+2) |
Capacitance (F) | 40mF | ±(3%+5) |
Frequency (Hz) | 400Hz~40mHz | ±(0.1%+4) |
Features | ||
Display count | 4000 | |
hFE | Transistor measurement | √ |
NCV | Non-contact voltage detection | √ |
Diode/transistor | √ | |
Continuity buzzer | √ | |
Data hold/Auto power off | √ | |
Low battery/Indication | √ | |
LCD backlight | √ | |
Safety rating | CAT Ⅱ 1000V, CAT Ⅲ 600V | √ |
Drop test | 2m | √ |
General Characteristics | ||
Power | 1.5V battery (R6) x 2 | |
Display | 56.5mm x 36mm | |
Product color | Red and grey | |
Product net weight | 330g | |
Product size | 175mm x 83mm x 53mm | |
Standard accessories | Batteries, test leads | |
. | ||
Based on 0 reviews
Be the first to review “UT136B+ Digital Multimeter”
-
Oscilloscopes
UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
-
Power Quality Analyzer
PQM-707 Power Quality Analyzer
-
Features:
- 7″ touch screen – intuitive operating
- CAT IV 600V – high safety
- all parameters acc. to class S – high accuracy of measurements
- Li-Ion rechargeable battery – higher mobility
- removable memory card – recording data with no restrictions
Possible measurements:
- Measurements according to EN 50160,
- Voltage L1, L2, L3, N-PE (five inputs),
– average, minimum, maximum values, range to 760 V, ability to work with voltage transformers, - Current L1, L2, L3, N (four inputs),
– average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers, - Crest factor for voltage and current,
- Frequency from 40 Hz to 70 Hz ,
- Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
- Power recording:
- Budeanu method,
- IEEE 1459,
- Active, reactive, apparent energy,
- Power factor, cosφ, tgφ,
- Up to 50th harmonics for voltage and current,
- Total Harmonic Distortion (THD) for voltage and current,
- Short-term (PST) and long-term (PLT) flicker,
- Unbalance of voltage and current,
- Current and voltage events registration including waveforms and RMS graphs half period,
- Inrush current
- Calculator of energy tariffs
- ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
SKU: n/a -
There are no reviews yet.