UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.
UT18C Voltage And Continuity Testers
UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.
₨10,800 ₨13,000
Weight | 0.3 kg |
---|---|
Dimensions | 27 × 9 × 3 cm |
Specifications | Range | Best Accuracy |
Model | UT18C | |
LED AC/DC Voltage Indication (V) | 12V | 8V±2V |
24V | 18V±2V | |
50V | 38V±4V | |
120V | 92V±6V | |
230V | 174V±8V | |
400V | 320V±10V | |
690V | 550V±15V | |
Phase Rotation Test | Operating Voltage: 100V~690V | √ |
Frequency:50Hz~ 60Hz | ||
Single Lead(L2)Voltage Detection | Operating Voltage:100V~690V | √ |
Frequency: 50Hz~ 400Hz | ||
Continuity Test | Resistance: 0~100KΩ | √ |
Beeper and LED light Indicator | ||
RCD Test | Operating Voltage:230V(50Hz~400Hz) | √ |
Polarity Detection | Positive & Negative | √ |
Self-inspection | All LED or LCD indicator | √ |
No Power Test | Operating Voltage: 50VAC/120VDC~690VDC/AC | √ |
Features | ||
IP65 | √ | |
Auto Range | All Range | √ |
Exceed Voltage | Voltage Range:713V~788V | √ |
Auto standby | standby current <10uA | √ |
Silent mode | All Range | √ |
Work Light | All Range | √ |
Low Battery Indication | Voltage Range:2.2V~2.4V | √ |
LCD Display (Voltage+frequency) | 6V~ 690V (40Hz~400Hz) | ±(1.5%+5) |
General Characteristic | ||
Power | 1.5V Batteries(R03) × 2 | |
LCD Size | 31×20mm | |
Product Color | Red and Grey | |
Product Net Weight | 280g | |
Product Size | 272mm×85mm×31 mm | |
Standard Accessories | Batteries | |
Standard Individual Packing | Blister, English Manual | |
Standard Quantity Per Carton | 30PCs | |
Standard Carton Measurement | 440mm × 295mm × 455mm (0.079 CBM Per Standard Carton) | |
Standard Carton Gross Weight | 17.5Kg |
Based on 0 reviews
Be the first to review “UT18C Voltage And Continuity Testers”
-
-
Power Quality Analyzer
PQM-707 Power Quality Analyzer
-
Features:
- 7″ touch screen – intuitive operating
- CAT IV 600V – high safety
- all parameters acc. to class S – high accuracy of measurements
- Li-Ion rechargeable battery – higher mobility
- removable memory card – recording data with no restrictions
Possible measurements:
- Measurements according to EN 50160,
- Voltage L1, L2, L3, N-PE (five inputs),
– average, minimum, maximum values, range to 760 V, ability to work with voltage transformers, - Current L1, L2, L3, N (four inputs),
– average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers, - Crest factor for voltage and current,
- Frequency from 40 Hz to 70 Hz ,
- Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
- Power recording:
- Budeanu method,
- IEEE 1459,
- Active, reactive, apparent energy,
- Power factor, cosφ, tgφ,
- Up to 50th harmonics for voltage and current,
- Total Harmonic Distortion (THD) for voltage and current,
- Short-term (PST) and long-term (PLT) flicker,
- Unbalance of voltage and current,
- Current and voltage events registration including waveforms and RMS graphs half period,
- Inrush current
- Calculator of energy tariffs
- ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
SKU: n/a -
-
Phase Detector Meters
UT262A Non-Contact Phase Detector
UT262 series adopts clamp type non-contact measuring method, which means user doesn’t need to get in touch with high-voltage exposed wires. It can start detection after three super-induction and high-insulation clamps clamp the exterior of the three-phase wires, which is safer, more practical, and more effective. Beside phase sequence detection, UT262 series can be also used for live wire detection, simple electrical inspection, phase identification, missing-phase judgment, and wire breaker searching. It is a perfect tool for phase sequence detection, motor mounting, and wires maintenance.
SKU: 22000 -
Voltage Detector
UT12E-US AC Voltage Detector
features:
1. Auto power off
2. Buzzer
3. LED indication
4. IP 67
5. AC voltagedetection
6. High/Lowvoltage mode
7. Vibration modeApplications:
Low voltage mode: Low-voltage motor (<90V), audio systems, arc welding machines,underground mining lighting, cables with thick insulation layer and other weakelectromagnetic AC signals.
High voltage mode: Urban electric supply and three-phase systems (90~1000V). Forexample, power distribution units, electrical panels, electrical appliances.SKU: n/a
There are no reviews yet.