UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.
UT18C Voltage And Continuity Testers
UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.
₨10,800 ₨13,000
Weight | 0.3 kg |
---|---|
Dimensions | 27 × 9 × 3 cm |
Specifications | Range | Best Accuracy |
Model | UT18C | |
LED AC/DC Voltage Indication (V) | 12V | 8V±2V |
24V | 18V±2V | |
50V | 38V±4V | |
120V | 92V±6V | |
230V | 174V±8V | |
400V | 320V±10V | |
690V | 550V±15V | |
Phase Rotation Test | Operating Voltage: 100V~690V | √ |
Frequency:50Hz~ 60Hz | ||
Single Lead(L2)Voltage Detection | Operating Voltage:100V~690V | √ |
Frequency: 50Hz~ 400Hz | ||
Continuity Test | Resistance: 0~100KΩ | √ |
Beeper and LED light Indicator | ||
RCD Test | Operating Voltage:230V(50Hz~400Hz) | √ |
Polarity Detection | Positive & Negative | √ |
Self-inspection | All LED or LCD indicator | √ |
No Power Test | Operating Voltage: 50VAC/120VDC~690VDC/AC | √ |
Features | ||
IP65 | √ | |
Auto Range | All Range | √ |
Exceed Voltage | Voltage Range:713V~788V | √ |
Auto standby | standby current <10uA | √ |
Silent mode | All Range | √ |
Work Light | All Range | √ |
Low Battery Indication | Voltage Range:2.2V~2.4V | √ |
LCD Display (Voltage+frequency) | 6V~ 690V (40Hz~400Hz) | ±(1.5%+5) |
General Characteristic | ||
Power | 1.5V Batteries(R03) × 2 | |
LCD Size | 31×20mm | |
Product Color | Red and Grey | |
Product Net Weight | 280g | |
Product Size | 272mm×85mm×31 mm | |
Standard Accessories | Batteries | |
Standard Individual Packing | Blister, English Manual | |
Standard Quantity Per Carton | 30PCs | |
Standard Carton Measurement | 440mm × 295mm × 455mm (0.079 CBM Per Standard Carton) | |
Standard Carton Gross Weight | 17.5Kg |
Based on 0 reviews
Be the first to review “UT18C Voltage And Continuity Testers”
-
Multimeters
Plam Size Digital Multimeters UT132B
UT132 Series is a 3.5 digit palm sized digital multimeter with stable performance, and fashionable design. UT132 are safe and reliable manual ranged multimeters that can be used for measuring AC/DC voltage, resistance, capacitance, temperature, diode voltage drop, transistor hFE parameter, circuit continuity, square wave output and so on. Its adapter plug socket can conveniently test surface mount devices. UT132 can be used for home, schools, factories, electrical and chemical engineering, and other areas. It is a great tool for circuit maintenance and electrical equipment repair.
SKU: n/a -
Phase Detector Meters
TKF-12 Phase Sequence Tester
Phase sequence indication (direction of field rotation) in the power network with rated phase-to-phase voltage (120…690 V) AC by LED signalization.
Operation in the power network with frequency range 10…70 Hz.
Indication of the voltage presence in the particular phases by neon lamps signalization.
Power supply from the tested network (continuous operation to 15 minutes for max. voltage).
Protection against faulty indication of field rotation.SKU: n/a -
Multimeters
UT195M Professional Digital Multimeter
Features
1. IP65 rating, 2m drop proof, CAT III 1000V, CAT IV 600V
2. Large 6000-count LCD screen
3. True RMS
4. ACV 750V 5kHz bandwidth
5. Flashlight
6. Auto LCD backlight controlled by light sensor (can be turned off)
7. LoZ voltage test, for ghost voltage measurement
8. Motor phase sequence measurement with 2 probes
9. 20A current measurement (max 30 seconds)
SKU: n/a -
Wire & Cable Testers
TDR-420 Time Domain Reflectometer/ Cable Fault Locator
Product features
- Possibility damage-free location of impedance changes of tested cables and wires such as:
- shorted conductor,
- open conductor / end of cable – useful during the inventory of warehouses and stores,
- splice,
- splitter,
- water ingress,
- wet splice,
- bridge tap
- or other changes.
- Single measurement mode ONCE,
- Continuously measurement mode CONT,
- Tone signal generator TONE,
- Two cursors to mark two places of damage along with an indication of the distance between them,
- Built-in HELP function for easier interpretation of the reflectogram,
- 11 available measuring ranges from 7 m to 6000 m,
- „dead zone” limited to 0.6 m,
- Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
- manually set of sensitivity in 8 steps GAIN,
- output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
- Velocity of Propagation set in range from 10% to 99%,
- tight and durable housing with IP67 ingress protection degree.
- Small size and weight.
SKU: n/a - Possibility damage-free location of impedance changes of tested cables and wires such as: