UT261 series is used for determining 3-phase power phase sequence, missing phase indication, and motor phase  rotation (UT261B). UT261A and UT261B can measure AC voltage of 40~700V and 90~600V respectively.  These devices can operate in frequency range of 15~400Hz. UT261 are durable devices which can withstand impact from 2 meter’ s height. Test leads with protective tubing are included in optional accessories.

13,200 16,350

20 in stock

Compare

UT261 series is used for determining 3-phase power phase sequence, missing phase indication, and motor phase  rotation (UT261B). UT261A and UT261B can measure AC voltage of 40~700V and 90~600V respectively.  These devices can operate in frequency range of 15~400Hz. UT261 are durable devices which can withstand impact from 2 meter’ s height. Test leads with protective tubing are included in optional accessories.

Weight 0.2 kg
Dimensions 12 × 7 × 3 cm

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT261B Phase Sequence and Motor Rotation Indicator”

There are no reviews yet.

  • UNI-T MSO3254E 250MHz Mixed Signal 4 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • UT219E ACA Professional Clamp Meters

    0 out of 5
    (0)

    Features

    1. 2m drop proof, IP54, CAT IV 600V

    2. Large 6000-digit LCD backlight (auto) display

    3. True RMS

    4. LoZ voltage test, for ghost voltage measurement

    5. MAX/MIN/REL testing mode, data hold, excluding the test lead interference of resistance measurement

    SKU: n/a
  • Uni-T UT337 Carbon Monoxide Meter

    0 out of 5
    (0)

    Suitable for use everywhere from in the house to restaurants, offices and industrial areas, the UT337A measures the exact value of carbon monoxide (CO) present in the air. Featuring a built-in sensor integrated into the top of the unit, the UT337A measures CO content from 0-1000ppm with accuracy of ±5% (5ppm) and resolution of 1ppm. The sensor is also designed to adjust rapidly to changes, ensuring you always get a stable, accurate reading. When CO levels exceed a certain threshold, the UT337A will alert the user by using a combination of audible and LED light indicators. The alarm is configurable to the user’s specification and it is also possible to use this meter to calculate temperature values.

    SKU: n/a
  • JM-8146 47 in 1 Household Maintenance Tool

    0 out of 5
    (0)

    Multi-function Tools

    SKU: n/a
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a