-19%

UT502A Insulation Resistance Tester

Availability:

Out of stock


1. 2000 count LCD display, overload indication, backlight

2. AC voltage measurement, auto power off
3. Auto discharge
4. Continuous measurements mode, red warning light and buzzer function
5. Continuous low resistance measurement
6.  PI and DAR measurement, auto resistivity calculation
7. Low resistance returning to zero function to improve accuracy

24,852 30,793

Out of stock

Compare
UT500 series insulation testers are used to measure the insulation resistance of electrical  equipment and household appliances. This is done by measuring the insulation resistance between electrical circuits or between circuits and ground. UT500 series can measure insulation resistance, AC Voltage, low resistance, PI (Polarization Index) and DAR (Dielectric Absorption). These are dieal  tools for ensuring transformers, genera-tors, high voltage motors, power capacitors, power cbles, arresters and other electrical equipment that can oprate in a safe and accurate manner.
Applications:
It is used for insulation resistance measurement for insulation materials and various kinds of electric equipments such as transformer, electric machines, cables, switches, electrical appliance, a ideal tool for electric maintenance, testing and inspection.
Category:
Weight 0.5 kg
Dimensions 15 × 10 × 7 cm
Specifications Range UT502A
Insulation resistance (Ω) Test voltages 500V/1000V/2500V 0%~10%
500V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~5GΩ ±(5%+5)
1000V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~5GΩ ±(5%+5)
2500V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~9.9GΩ ±(5%+5)
10GΩ~20GΩ ±(10%+5)
Load current 50V (R=50kΩ) 1mA 0%~10%
100V (R=100kΩ) 1mA 0%~10%
250V (R=250kΩ) 1mA 0%~10%
500V (R=500kΩ) 1mA 0%~10%
1000V (R=1MΩ) 1mA 0%~10%
2500V (R=1MΩ) 1mA 0%~10%
Short-circuit current <2mA
Low resistance (Ω) 0.01Ω~200Ω (about 5.0V/>200mA) ±(2%+3)
AC voltage (V) 30V~600V ±(2%+3)
Features
Display count 2000
DAR 60s/15s and 60s/30s
PI
Auto range/Low battery indication
LCD backlight/Light alarm
Buzzer alarm/High voltage indication
Over load indication/Auto discharge
Test voltage secondary display
10MΩ internal resistance test
Meets IEC 61557 61557-1:2007; 61557-2:2007; 61557-4:2007
General Characterisitics
Power 1.5V battery (LR6) x 6
Display 70.6mm x 34mm
Product color Red and grey
Product net weight 500g
Product size 150mm x 100mm x 71mm
Standard accessories Batteries, test leads, alligator clips, gallus, test probes
Standard individual packing Gift box, carrying bag, English manual
Standard quantity per carton 20pcs
Standard carton measurement 500mm x 380mm x 330mm (0.063 CBM per standard carton)
Standard carton gross weight 18.9kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT502A Insulation Resistance Tester”

There are no reviews yet.

  • UT120B Pocket Size Type Digital Multimeters

    0 out of 5
    (0)

    Main Features

    1. Auto range

    2. Auto polarity indication

    3. Relative mode

    4. Data hold

    5. Auto power off

    6. Capacitance measurement

    7. Complies with CE (European Union) directives

    SKU: n/a
  • UT521 Earth Groud Testers

    0 out of 5
    (0)

    UT520 series earth resistance tester hasthe functions of backlight display, low battery display, data hold, datastorage, auto power off and power saving. It can not only be used for accurate three-wiremeasurement but also simple two-wire measurement.

    It is applicable to measuring the earthresistance of all kinds of electrical power system, electrical equipment and anti-thunderequipment. It can also measure the earth voltage. It is applicable to testingoperating earth systems of smelting, communication, manufacture, fossil oil,national defense, electricity, chemical industry and construction.

    SKU: n/a
  • CLAMP METER AC BM 2000B

    0 out of 5
    (0)

    SPECIFICATIONS:

    – Maximum display: 1999
    – Method indication: LCD
    – Maximum arm span: 60mm
    – Operating temperature range:
    work: 0C – 40C
    Storage:-10C – 60C
    – Power supply: 9V battery
    – Low battery indication: YES, graphic symbol
    – Audible indication: YES, piezoelectric transducer
    – Dimensions: 270x100x45 mm
    – Weight: about 610g (with battery)

    Features
    – Measuring voltage: 0-1000V 2 range
    – Measurement of AC voltage: 0-700V in 1 range
    – Measurement of alternating current: 200A-2000A in 2 ranges
    – Measuring current: 200A-2000A in 2 ranges
    – Measurement of resistance: 2k in 1 range
    – Measuring capacity: NO
    – Frequency: NO
    – Temperature measurement: NO
    – Testing LEDs: YES
    – Acoustic continuity tester: YES
    – Distance between arms: 6cm
    – Meter dimensions: 270x100x45 mm
    – Weight: 610g with battery
    – Basic accuracy: ± (0.5% +2 digits)

    Packages Include:

    1 × Clamp-On Meter BM-2000B

    An internal link is any link from one page on your website to another page on your website. Both your users and search engines use links to find content on your website. Your users use links to navigate through your site and to find the content they want to find. Search engines also use links to navigate your site. They won’t find a page if there are no links to it. There are several types of internal links. In addition to links on your homepage,mean post feed, etc, you can also add links within your content. We call those contextual links. Contextual links point your users to interesting and related content.
    SKU: n/a
  • UT381 illuminometers

    0 out of 5
    (0)

    UT380 series professional pocket type illuminometer has the features of high integration level, low power dissipation and high test precision. It can test light intensity from 0 to 20000 Lux. UT382 can communicate with PC, which real time stores and analyzes data.  It can also transmit the data stored in the illuminometer to computer, which analyzes, prints and saves the data. It is applicable to illumination site test. It is the best choice to measure plaza, gym, waiting hall and business site.

     

    SKU: n/a
  • UT60C Modern Digital Multimeters

    0 out of 5
    (0)

    Product Features

    1. Analogue bar graph

    2. Diode test and buzzer continuity

    3. Transistor measurement

    4. Auto range

    5. MAX/MIN/REL measurement mode

    SKU: n/a