Specifications Range Best Accuracy
Model UT52
DC Voltage (V) 200mV/2V/20V/200V/1000V ±(0.5%+1)
AC Voltage (V) 200mV/2V/20V/200V/750V ±(0.8%+3)
DC Current (A) 2mA/20mA/200mA/20A ±(0.8%+1)
AC Current (A) 2mA/20mA/200mA/20A ±(1%+3)
Resistance (Ω) 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ/200MΩ ±(0.8%+1)
Capacitance (F) 2nF/20nF/200nF/2μF/20μF ±(4%+3)
Features
Fused 10A Range
Transistor
Diode
Continuity Buzzer
Low Battery Display
Input Impedance for DC Voltage Measurement 10MΩ
Max. Display 1999
General Characteristic 
Power 9V Battery (6F22)
LCD Size 65mm×33mm
Product Colour Red and Grey
Product Net Weight 560g (including holster)
Product Size 190mm×88mm×34mm
Standard Accessories Test Lead, Batteryl, Holster
Optional Accessories* Clip-On Test Lead Light (UT-TL), Built-In Test Lead Light (UT-L1), Built-In Test Lead Light Plus (UT-L2)

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT52 Standard Digital Multimeters”

There are no reviews yet.

  • UT213C ACA DCA Digital Clamp Meters

    0 out of 5
    (0)

    Main Features

    1. 10A/400A AC/DC measurement with Hall-effect sensor

    2. Auto range makes measurement faster and more effective

    3. 4000 display count, 3/s sampling rate

    4. True RMS measurement

    5. NCV, Non-Contact AC Voltage testing

    6. Frequency and duty ratio measurement

    7. MAX/MIN mode

    8. Relative mode

    9. Flashlight function for measuring at night or in the dark

    10. K-type point contact temperature probe for temperature measurement

    11. Large jaw of 30mm

    12. Data hold

    13. LCD backlight

    14. Auto power off

    15. 1m drop proof

    16. Complies with CE (European Union) directives

    SKU: n/a
  • Digital Storage Oscilloscope UTD2202CM

    0 out of 5
    (0)

    Specifications and features:

    1. 2 channels,1GS/s sample rate

    2. 200MHzbandwidth, 16Mpts maximum memory depth

    3. Waveformacquisition rate is up to 150,000wfms/s

    4. Verticalsensitivity: 2mV/div~5V/div

    5. Time-basedrange: 2ns/div~50s/div

    6. Trigger modes:edge, pluse, runt, video, slope, alternate

    7. Customized AUTO,fast captures the signals

    9. Supports Y-T andX-Y mode at the same time, can observe Lissajous waveform

    10. 34 kinds ofauto measurements

    11. Optional LAmodule

    12. Standardinterfaces: USB Host,USBDevice,Pass/Fail

    13. 7-inch TFT LCD,WVGA (800*480)

    SKU: n/a
  • YH TIP 902

    0 out of 5
    (0)
    SKU: n/a
  • UT516B Insulation Resistance Tester

    0 out of 5
    (0)

    Features of UT516B Insulation Resistance Tester

    ● AC/DC voltage

    ● USB data transfer
    ● Low battery indication
    ● Data storage
    ● LCD backlight
    ● Polarization Index
    ● Over-range alarm
    ● 9999 Max display
    ● Comparative measurement
    ● Measurement time selection
    SKU: n/a
  • UPO2104CS 4 Channels Ultra Phosphor Oscilloscope

    0 out of 5
    (0)

    Features and Benefits:
    1、Sample Rate up to 1GS/s;
    2、Channels 4;
    3、Bandwidth 100MHz,;
    4、Memory Depth 28Mpts (Standard);
    5、Waveform Capture Rate up to 50,000wfms/s;
    6、With 256 level intensity grading display;
    7、Up to 65,000 frames for Waveform Record ,Replay;
    8、Support serial bus trigger and decoding;
    9、8 inches, TFT LCD,WVGA(800*480);
    10、Interface:USB Host, USB Device, LAN, VGA, AUX OUT, 10MHz input/output.

    SKU: UP21O02CSMHZ
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a