Based on 0 reviews
Be the first to review “YH S218A PIPE”
-
Clamp Meters
UT207A Digital Clamp Meters (Discontinued)
Features of UT207/A to UT209/A Series 1000A Digital Clamp Meters
Certificates: CE, RoHS
● 1000A AC/DC current measurement, 3 times/s sampling rate
● Auto/manual ranges selectable (UT207A/UT208A/UT209A)
● True RMS (UT207/UT208/UT209/UT209A)
● Analog bar graph (UT209)
● Inrush current (UT207/UT208)
● Zeroing function
● Full icon display (UT207/UT208/UT209)
● MAX/MIN (UT207/UT208/UT209)
● LCD backlight (UT207A/UT208A/UT209A)
● Data hold; Duty cycle (except UT209 )
● Auto power off and low battery indication
● Point contact temperature probe (UT208/UT208A)
● Diode; Continuity buzzer; Input Impedance for DCVSKU: n/a -
Voltage Detector
UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V) (Discontinued)
Features of UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V)
Certifications: CE, RoHS, UL
● Complies with CAT IV 600V (UT13A); prevent damage caused by transient voltage
● CAT IV 1000V (UT13B)
● LED indication
● Vibration indication (UT13B)
● Adjustable sensitivitySKU: n/a -
Insulation Tester
MIC-15k1 ,15kV Insulation Quality Analyzer
Features:
- Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
- It allows testing the electrical durability of the tested object – breakdown voltage indication.
- High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
- The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
- Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
- visual method (if power cables are visible along the entire length),
- reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
- Compatible with external software.
SKU: n/a -
Multi Function Calibrator
UT705 Single Function Loop Calibrator
1. Measures: DC voltage, DC current, 4-20mA loop current
2. Output functions: DC current, analog transmitter, 24V loop3. Up to 0.02% accuracy current measurement at the same time4. Automatic ramp for DC current output5. Manual stepping and automatic stepping and ramping output6. Stores and recalls setupsSKU: n/a
There are no reviews yet.