-29%

Battery Load Tester – BT 100D

Availability:

7 in stock


  • 100 Amp Digital Battery Load Tester
  • Microprocessor Control–makes for an easy and accurate load test with no need to time yourself
  • Bright, LED Digital Display–indicates both voltage and test results
  • Unique 3-Step Design–LED polarity check function, battery load test and charging system test readout
  • Super-Grip Battery Clamps–heavy-duty and color-coded
  • Baked Enamel, Steel Case–ventilated to keep cool
  • Rubber Insulated Carrying Handle–for comfort and safety
  • Checks both Battery and Charging System

5,000 7,000

7 in stock

Compare

The BT-100D 100+ Amp Digital Battery Load Tester is microprocessor controlled. It makes for an easy and accurate load test with no need to time yourself to get accurate results. Bright, LED Digital Display indicates both voltage and test results. A unique 3-Step Design provides LED polarity check function, battery load test and charging system test readout. Automatically Turns Off the Load after 10 seconds and locks the voltage. Super-Grip Battery Clamps are heavy-duty and color-coded. Baked Enamel, Steel Case to keep cool. Rubber Insulated Carrying Handle–for comfort and safety. Checks both Battery and Charging System.

Category: Tag:
Weight 0.7 kg
Dimensions 15 × 8 × 6 cm

12 Volt Battery Analysis

Press “START TEST” & wait for 10 seconds.
Once automatic test cycle is completed, your test results will be:

1.
 GREEN LIGHT = OK):
Battery capacity is good. May or may not be fully charged.
Determine state of charge by checking specific gravity (use hydrometer). If gravity is less than full charge, check for possible charging system trouble or electrical drain. Recharge battery to fully charged level.

2. GREEN + YELLOW LIGHT = OK BUT WEAK):
Review the load test result with the comparison chart on the tester cover to see if this battery is “OK” or not. If it is “OK”, go up to 1ST “OK” state. If it is not, go down to 3rd “WEAK” state.

3. YELLOW LIGHT = WEAK):
Battery capacity is unsatisfactory. Battery may be either: (1) defective or (2) partially discharged. To determine which, check specific gravity. If gravity is over 1.225, battery is considered defective. If gravity is under 1.225, recharge battery and re-test. If cell-to-cell gravity varies more than 0.025 (25 points), cell trouble may exist. If charging does not bring gravity to fully charged level, the battery is either sulfated or has lost active material.

4. RED LIGHT = BAD):
Battery may be defective (e.g. a bad cell).

NOTE: If pre-test battery voltage is below 12.3V, tester will not allow and should not perform the load test. Please fully charge battery and retest.

Brand

TITAN

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Battery Load Tester – BT 100D”

There are no reviews yet.

  • AC/DC DIGITAL CLAMP METER KT 203

    0 out of 5
    (0)

    AC/DC DIGITAL CLAMP METER KT 203

    • Small and handy clamp meter
    • IEC 6101C Clamp meter
    • DMM function A0-1 Safety Standard CAT Ⅲ 300V, CAT Ⅱ 600V

    • 400A AC/DCV, DCV, Ω, Continuity Buzzer.

    SKU: n/a
  • UTD2025CL Digital Storage Oscilloscope

    0 out of 5
    (0)

    1. Dual analog channels width range 1mV/div~20V/div;
    2. 7 inches widescreen LCD displays;
    3. Special Print Scree Feature;
    4. Supports plug-and-play USB storage device. Communication with and remote control of computer through the USB device;
    5. USB drive system software upgrade;
    6. Storage of waveforms setups and interfaces waveforms and setups reproduction;
    7. Automatic measurement of 28 waveform parameters;
    8. Unique waveform recording and replay function;
    9. Multilingual menu displays.

    SKU: n/a
  • 40W Soldering Iron Soldering Tool

    0 out of 5
    (0)

    soldering iron is a hand tool used to heat solder, usually from an electrical supply at high temperatures above the melting point of the metal alloy. This allows for the solder to flow between the workpieces needing to be joined.

    SKU: n/a
  • UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • MIC-5001, 5000V Insulation Tester

    0 out of 5
    (0)

    Insulation resistance measurement in a compact, light-weight, low-cost design.

    • Measurement to 5 TΩ
    • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
    • Continuous indication of insulation resistance or leakage current
    • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
    • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
    • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
    • Continuous display of test voltage during the measurement
    • Protection against measuring live objects
    • Two and three-lead measurement method
    • Ramp Test Insulation resistance measurement
    • Measurement of breakdown voltage with increments up to 1 kV / s
    • Measurement of alternating and direct voltages from 0 V to 750 V
    • 990 cells of memory (11880 records) to record results
    • Data transfer to PC via USB cable
    • Built-in rechargeable battery pack
    • Meets the requirements of the EN 61557 standard
    • Charge from optional car lighter (12 V) socket accessory
    SKU: n/a