Specifications Range UT202+
AC current (A) 400A ±(2%+10)
600A
AC current frequency (Hz) 50Hz~100Hz ±(1%+5)
AC voltage (V) 600V ±(0.8%+5)
AC voltage frequency(Hz) 10Hz~10kHz ±(1%+5)
10Hz~60kHz
Resistance (Ω) 40MΩ ±(0.8%+2)
60MΩ
Capacitance (F) 4mF ±(4%+5)
40mF
60mF
Temperature (℃) -40℃~1000℃ ±(1.5%+5)
Frequency (Hz) 10Hz~10MHz
Features
Display count 4000
Auto range
Jaw opening 28mm
True RMS
NCV
Live wire test
Continuity test
Diode
MAX/MIN
Relative mode
Zero mode
Data hold
Low battery indication
Auto power off
General Characterisitics
Power 1.5V battery (R03) x 2
Display 37mm x 25mm
Product color Red and grey
Product net weight 248g
Product size 215mm x 63mm x 36mm
Standard accessories Batteries, test leads, Themocouple
Standard individual packing Gift box, Carring bag, English manual
Standard quantity per carton 40pcs
Standard carton measurement 485mm x 295mm x 385mm
Standard carton gross weight 17.8kg

5,820 5,945

4 in stock

Compare
  • 1.Industrial electricity
  • 2.Residential electricity
  • 3.Air conditioning
  • 4.Automobile
Category:
Weight 0.3 kg
Dimensions 21 × 6 × 4 cm

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Digital Clamp Meter UT202+ UNI-T”

There are no reviews yet.

  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a
  • RF-7050PRo+PO-88

    0 out of 5
    (0)
    SKU: n/a
  • UT201+ ACA Digital Clamp Meters

    0 out of 5
    (0)

    1. Auto range and 3/s sampling rate

    2. Data hold

    3. Max value hold

    4. Auto power off

    5. Low battery prompt, over-range prompt and auto polarity display

    6. Comfortable tohold and easy to carry with (Product weight: 220g)

    7. 1m drop proof

    8. Complies with Double Insulationand Over Voltage standards of CAT II 600V, CAT III 300V and Pollution Degree 2

    9. Complies with CE (European Union) directives

    SKU: n/a
  • CLAMP METER AC BM 5268

    0 out of 5
    (0)
    BM5268 AC Digital Clamp meter Technical parameters
    Functions Range Accuracy
    BM5268
      DC  Voltage   400mV/4V/40V/400V/600V ±(0.8%+2)
      AC  Voltage   4/40/400/600V ±(1.2%+5)
      AC  Current   4/40/400/600A ±(2%+10)
      Ω  Resistance   400/4K/40K/400K/4M/40MΩ ±(1%+3)
      Capacitance   10n/100n/1μ/10μ/100μ/1m/10mF ±(3%+5)
       Frequency   10/100/1K/10K/100K/1M/30MHz ±(0.5%+3)
       ºC/ºF   -50ºC~1000ºC ±(1%+5)
       -58ºF~1832ºF ±(1.2%+6)
      Functions Range Accuracy
      True RMS
      Manual range
      Automatic range
      Auto power OFF About  10minutes
    Auto power OFF/Manually turn it off
      Diode Test
      VHZ      voltage measuring frequency
    Phase line recognition
      Continuity Testing
      Data hold
      INR Surge voltage
      low Battery indication
      Overload protection
    Greatest display 1999
      Jaw Size Φ30mm
            General Features
      Power                                     DC9V(6F22)Battery
      Color Gray+Red
      Weight About 220g
     Size 195×64×35mm
      Standard accessories Multimeter leads+Batteries+Temperature Sensor
      Standard Pack Color Box,User Manua
      Safety rating EN61010-1,CAT.II 600V

     

     

    SKU: n/a
  • UT123D

    0 out of 5
    (0)

    ● True RMS
    ● NCV/Live
    ● Low Battery Indication: ≤2.7V
    ● Data Hold
    ● Auto Power Off
    ● Acousto-optic indication: NCV/continuity/battery power

    SKU: n/a
  • CLAMP METER AC BM 528F

    0 out of 5
    (0)
    Product Description
    BM528F AC Digital Clamp meter Technical parameters
    Functions
    Range
    Accuracy

    (BM528F)
    DC Voltage
    200mV/2V/20V/200V/1000V
    ±(0.8%+2)
    AC Voltage
    2V/20V/200V/700V
    ±(1.2%+5)
    AC Current
    2A/20A/200A/600A
    ±(2%+10)
    Ω Resistance
    200/2K/20K/200K/2M/20MΩ
    ±(1%+3)
    Capacitance
    20n/200n/2μ/20μ/200μ/2mF
    ±(3%+5)
    Frequency
    200/2K/20K/200K/2M/20MHz
    ±(0.5%+3)
    ℃ / ℉
    -50℃ ~1000℃

    -58℉~1832℉

    ±(1%+5)

    ±(1.2%+6)
    SKU: n/a