  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).

11,844 14,478

5 in stock

Compare

The most important features of CMM-10 are:

  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).
Category:
Weight 0.2 kg
Dimensions 14 × 7 × 4 cm

Frequency measurement

Range Resolution Accuracy
5,000 Hz 0,001 Hz ±(1,5% m.v. + 5 digits)
50,00 Hz 0,01 Hz
500,0 Hz 0,1 Hz ±(1,2% m.v. + 3 digits)
5,000 kHz 0,001 kHz
50,00 kHz 0,01 kHz
500,0 kHz 0,1 kHz
5,000 MHz 0,001 MHz ±(1,5% m.v. + 4 digits)
10,00 MHz 0,01 MHz
  • sensitivity: ≥8 V RMS

Duty cycle measurement

Range Resolution Accuracy
0,1…99,9% 0,1% ±(1,2% m.v. + 2 digits)
  • sensitivity: ≥8 V RMS,
  • pulse width: 100µs – 100 ms,
  • frequency width: 5 Hz…150 kHz.

Temperature measurement

Range Resolution Accuracy*
-20°C…+760°C 1°C ±(3% m.v. + 5°C, 9°F)
-4°F…+1400°F 1°F

*) probe (K type) accuracy not included

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,5% m.v. + 2 digits)
4,000 V 0,001 V ±(1,2% m.v. + 2 digits)
40,00 V 0,01 V ±(1,2% m.v. + 2 digits)
400,0 V 0,1 V
600 V 1 V ±(1,5% m.v. + 2 digits)
  • input impedance: 7,8 MΩ

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 70 digits)
4,000 V 0,001 V ±(1,2% m.v. + 3 digits)
40,00 V 0,01 V ±(1,5% m.v. + 3 digits)
400,0 V 0,1 V
600 V 1 V ±(2,0% m.v. + 4 digits)
  • input impedance: 7,8 MΩ,
  • frequency range: 50…400 Hz.

DC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,0% m.v. + 3 digits)
4 000 μA 1 μA ±(1,5% m.v. + 3 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(2,5% m.v. + 5 digits)
10,00 A 0,01 A

AC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,5% m.v. + 5 digits)
4 000 μA 1 μA ±(1,8% m.v. + 5 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(3,0% m.v. + 7 digitgs)
10,00 A 0,01 A
  • frequency range: 50…400 Hz.

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,2% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,0% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,2% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ
4,000 MΩ 0,001 MΩ
40,00 MΩ 0,01 MΩ ±(2,0% m.v. + 3 digits)

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(5,0% m.v. + 7 digits)
400,0 nF 0,1 nF ±(3,0% m.v. + 5 digits)
4,000 μF 0,001 μF
40,00 μF 0,01 μF
100,0 μF 0,1 μF ±(5,0% m.v. + 5 digits)

“m.v” = measured value

Electric security:

  • type of insulation: double, according to EN 61010 – 1 and IEC 61557
  • measurement category: CAT II 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • diode test: I=0,3 mA, U0 = 1,5 V DC
  • continuity test: I<0,3 mA, sound signal for R<50 Ω
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 7,8 MΩ (V AC/DC)
  • display: 5000 counts LCD display with function indication
  • dimensions: 138 x 68 x 37 mm
  • weight: approx. 210 g
  • fuses: mA, µA range: 0,5 A/250 V fast; A range: 10 A/250 V fast
  • auto power OFF: 30 min.
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032

Rated operational conditions:

  • operating temperature: 0…+50°C at <70% rel. humidity
  • storage temperature: -20…+60°C at <80% rel. humidity

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMM-10 Multimeter”

There are no reviews yet.

  • UT275 Clamp Earth Ground Testers

    0 out of 5
    (0)

    UT270 series can measure the grounding system of a circuit without disconnecting the ground wires and auxiliary electrode. It clamps the grounding circuit and measures the grounding resistance fast and safely. It can measure resistance as low as 0.01Ω and has a high resolution of 0.001Ω. It has overload alarm function, which can help to setup the alarm value within the ranges. The clamp has double insulation, which strengthens the anti-interference.

    SKU: 90000
  • UT281C True RMS AC 3000A Flexible Clamp Meters

    0 out of 5
    (0)

    1. 2m drop proof, IP54, ETL/Intertek certified 3rdedition CE

    2. Coil diameter: 0.75cm, bending length: 24.5cm for UT281A and 45.7cm for UT281C

    3. Large LCD display for clear reading

    4. True RMS

    5. Long press INRUSH key for 2s to measure inrush current

    6. Datahold, backlight, auto power off

    SKU: n/a
  • MECHANIC lead-free ESD soldering tip 900M-T-I

    0 out of 5
    (0)

    MECHANIC lead-free ESD soldering tip 900M-T-I

    High precision, no oxygen copper, anti-static, long service life

    SKU: n/a
  • UT330T USB Temperature datalogger

    0 out of 5
    (0)

    Features of UT330T USB Temperature datalogger

    Certificates: CE, RoHS

    ● 64000 groups data storage
    ● Adjustable sampling interval
    ● IP65
    ● Alarm threshold
    ● Auto record time setup
    ● Cyclic recording
    ● Low battery indication
    ● LED alarm
    SKU: n/a