UT270 series is widely used in earth ground and circuit resistance measurements of electric power, telecommunications, meteorology, oil field, construction and industrial electrical equipment. It can measure the ground system of the circuit without disconnecting grounding wires, auxiliary electrode. UT278A can also measure leakage current and neutralline current of earth ground system.
UT278A Clamp Earth Ground Testers
Out of stock
UT270 series is widely used in earth ground and circuit resistance measurements of electric power, telecommunications, meteorology, oil field, construction and industrial electrical equipment. It can measure the ground system of the circuit without disconnecting grounding wires, auxiliary electrode. UT278A can also measure leakage current and neutralline current of earth ground system
.
₨0
Out of stock
CompareWeight | 1.1 kg |
---|---|
Dimensions | 28 × 8 × 6 cm |
Specifications | Range | Best Accuracy |
Model | UT278A | |
Earth Ground Resistance (Ω) | 0.01Ω-0.099Ω | ±(1%+0.01) |
0.1Ω-0.99Ω | ±(1%+0.01) | |
1.0Ω-49.9Ω | ±(1%+0.1) | |
50Ω-99.5Ω | ±(2%+0.5) | |
100Ω-199Ω | ±(3%+1) | |
200Ω-395Ω | ±(6%+5) | |
400Ω-590Ω | ±(10%+10) | |
600Ω-800Ω | ±(20%+20) | |
800Ω-1200Ω | ±(25%+30) | |
Leakage Current(A) | 0mA-9mA | ±(2.5%+1) |
10mA-99mA | ±(2.5%+5) | |
100mA-299mA | ±(2.5%+10) | |
0.30A-2.99A | ±(2.5%+0.1) | |
3.0A-9.9A | ±(2.5%+0.3) | |
10.0A-20.0A | ±(2.5%+0.5) | |
3A-30A | ±(2.5%+0.5) | |
Features | ||
Display Count | 4 Digits Display LCD | √ |
Auto Range | √ | |
Jaw Capacity | 32mm | |
Single Measure Time | 1 Second | √ |
Resistance Measurement Frequency | >1KHz | √ |
Current Measurement Frequency | 50Hz/60Hz | √ |
Resistance Limit Alarm | 1Ω-199Ω | √ |
Current Limit Alarm | 1mA-499mA | √ |
Beeper and Light Alarm | √ | |
Jamming Signal Recognition | √ | |
Over-Range Display | √ | |
Low Battery Indication | √ | |
Data Logging | 99 | |
General Characteristic | ||
Power | 1.5V Alkaline Batteries(LR6)X 4 | |
LCD Size | 47mm X 28.5mm | |
Product Color | Red and Grey | |
Product Net Weight | 1160g | |
Product Size | 285mm X 85mm X 56mm | |
Standard Accessories | Batteries, Test Ring, Tool Box | |
Standard Individual Packing | Gift Box, English Manual | |
Standard Quantity Per Carton | 6 PCs | |
Standard Carton Measurement | 610mm X 375mm X 320mm (0.073CBM Per Standard Carton) | |
Standard Carton Gross Weight | 25Kg | |
Optional Accessories | USB Interface Cable,PC Software CD |
Based on 0 reviews
Be the first to review “UT278A Clamp Earth Ground Testers”
-
Clamp Meters
UT 205A+
1. 1000A AC current measurement2. 1000V AC/DC voltage measurement3. 600A inrush current measurement (UT206A+)4. Temperature (UT206A+)5. NCV (UT206A+)6. ACV frequency 10Hz~10kHz7. Jaw opening: 45mm8. Resistance / capacitance / frequency measurement9. Auto range / backlight / low battery indication10. Continuity / diode / duty cycle11. MAX/MIN12. Data hold / flashlight / relative mode13. Auto power off14. CAT II 1000V/CAT III 600VSKU: n/a -
Multimeters
UT195E Professional Digital Multimeters
Features
1. IP65 rating, 2m drop proof, CAT III 1000V, CAT IV 600V
2. Large 6000-count LCD screen
3. True RMS
4. ACV 750V 5kHz bandwidth
5. Flashlight
6. Auto LCD backlight controlled by light sensor (can be turned off)
7. LoZ voltage test, for ghost voltage measurement
8. 20A current measurement (max 30 seconds)
9. 31 analogue bar