- Location damaged power cables.
- Fault location copper telecom cables.
- Coaxial cable fault location.
- Fault location wiring infrastructure.
- Detection of breaks, short circuits, damage caused by dampness and other changes in impedance of the cable.
- Graphic depiction of damage the cable with automatic indication the distance to fault on the screen.
Wire & Cable Testers
TDR-410 Cable Fault Locator
Availability:
Out of stock
-
Features:
- automatic or manual mode:
- the automatic fault location (AFL),
- mode with manual range selection and sensitivity,
- single measurement triggered manually or scanning continuous,
- 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
- maximum length of cable up to 4000 m one end of the cable,
- “Dead zone” measure limited to 0.5 m,
- 2.5 “LCD screen with backlight,
- scan automatically or manually trigger,
- sensitivity set manually or automatically adjusted,
- adjustable impedance matching,
- propagation coefficient adjustment 1% to 99%,
- waterproof and resistant to mechanical housing.
- small size and weight.
- economical power system – 30 hours of continuously scan on one battery set..
Accessories:
- 0,6 m double-wire lead: WAPRZ0X6DZBB
- red crocodile clip: WAKRORE20K02
- Krokodylek czarny: WAKROBL20K01
- cover M-2: WAFUTM2
- automatic or manual mode:
₨0
Out of stock
CompareDechnical data:
- Ranges Meters: 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km
- Ranges Feet: 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 14000.
- Range Selection: Manual range control / Auto range.
- Accuracy: 1% of selected range*.
- Resolution: Approx 1% of range.
- Minimum cable lenght: 4m (14ft).
- Sensitivity: Min 3 pixel return at 4km on 0.6mm Ø, PE, TP.
- Velocity Factor: Adjustable from 1% to 99%.
- Output Pulse: 5 volts peak to peak into open circuit.
- Output Impedance: Selectable 25, 50, 75 & 100 Ω.
- Output Pulse: Width 3 ns to 3 µs, Automatic with range.
- Scan Rate: 2 scans/second or scan held, pre set for each range scale.
- Tone Generator: 810 – 1100Hz.
- Battery Life: 30 hours continuous scanning.
- Power Supply: 6 volts 4 x 1.5 AA Alkaline cells, on-screen low voltage indicator.
- Power Down Selectable: 1, 2, 3, 5 minutes or disabled.
- Back Lit Display: 128 x 64 pixel.
- Voltage Protection: 250 volts AC.
- Operating Temp: -10º / 50ºC.
- Storage Temp: -20º +70° C.
- Dimensions: 165 x 90 x 37 mm (6.5 x 3.5 x 1.5 ins).
- Weight: 350 g (12oz).
- Safety: IEC 61010-1, EN 60950.
- EMC: BS/EN 61326-1.
- Water/Dust Proof: IP54
Based on 0 reviews
Be the first to review “TDR-410 Cable Fault Locator”
-
Earth Ground Resistance Testers
MRU-30 Earth Resistance and Resistivity Meter
-
It allows to take the measurements of:
- earthing resistance using auxiliary electrodes,
- earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
- earthing resistance using double clamps for measuring multiple earthing without underground connections.
- ground resistivity (Wenner method),
- continuity of equipotential bondings and protective
- conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.
Additionally:
- measurement of resistance of auxiliary electrodes RS and RH,
- measurement of interference voltage,
- measurement in the presence of interference voltage in the power network
- with frequency 50Hz, 60Hz,
- selection of maximum measuring voltage (25V and 50V),
- introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
- memory of 990 measurements (10 banks of 99 cells each),
- calibration of clamp used,
- data transmission to the computer (USB),
- indication of battery state.
SKU: n/a -
-
Oscilloscopes
UNI-T 2 Channel UPO2102E Ultra Phosphor Oscilloscope
- 100MHz bandwidth
- number of channels 2
- sampling 1GS / s
- max memory depth 56Mpts (per channel) (previously 28Mpts per channel)
- waveforms per second up to 80,000 wfms/s (formerly 50,000 wfms/s)
- time base range 5ns/div – 50s/div
- input coupling (1MΩ ± 2%) // (20pF ± 3pF)
- verical axis 1mV/div – 20V/div (1MΩ)
- DC gain accuracy ± 3%
- number of saved waveforms 65000
- trigger : Edge, Window, Runt, Time Out, Nth Edge, Delay, Duration, Setup / Hold, Pulse Width, Slope, Video, Pattern, RS232 / UART, I2C, SPI
- mathematical operations with waveforms : A + B, A-B, AxB, A / B, FFT, Logic operation, Editable Advanced, Filter
- automatic Measurement : Max, Min, High, Low, Middle, Pk-Pk, Ample, Mean, Cycle Mean, RMS, Cycle RMS, Cycle Area, OverShoot, PreShoot, Period, Freq, Rise, Fall, + Width, -Width, + Duty, -Duty, RiseDelay, FallDelay, Phase, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF
- number of measurements : 5 simultaneous measurements
- statistics : Mean, Max, Min, standard deviation, number of measurements
- frequency counter : 6 bits
- standard interfaces : USB-Host, USB-Device, LAN, AUX (Trig Out, Pass / Fail)
SKU: n/a -
Distance Meter
LM 100A Laser Distance Meters
Features of LM A Series Laser Distance Meters
Certificates: CE, UKCA
● Ergonomic exterior, comfortable handling
● Millimeter accuracy
● 99 groups data storage
● Quick, self calculation with real-time readout
● Physical leveler(Horizontal and vertical)
● Multiple functions: Max/Min/continuous measurement, data storage, etcSKU: n/a -
-
Earth Ground Resistance Testers
MRU-10 Earth Resistance Meter
It allows to:
- measure earthing resistance using auxiliary electrodes,
- measurement of resistance of auxiliary electrodes RS and RH,
- measurement of interference voltage,
- measurement in the presence of interference voltage in the power network with frequency 50 Hz and 60 Hz,
- selection of maximum measuring voltage (25 V and 50 V),
- indication of battery state.