Fluke 15B+ Digital Multimeter

Availability:

Out of stock


Key features

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

21,058

Out of stock

Compare

Fluke quality is always within your reach

Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B+ digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B+ offers everything you need.

Category:

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 15B+ Digital Multimeter”

There are no reviews yet.

  • UNI-T UTL8212 High-Precision Compact DC Electronic Load Tester Single/Dual Channel 150V Power Supply Current Test – UTL821

    0 out of 5
    (0)

    Power supply test, adapter/charger test, battery test, lithium battery protection board test, ATE, component test, etc., commonly used in home appliance manufacturers, LCD and other computer component manufacturers, switching power supply and LED manufacturers, adapter charger manufacturers and other companies Production and testing use

    SKU: n/a
  • YH 900M IS TIP

    0 out of 5
    (0)
    SKU: n/a
  • ,

    [NEW] JM-Z21

    0 out of 5
    (0)
    SKU: n/a
  • YH 08B TIP CLEANER

    0 out of 5
    (0)
    Note: Products with electrical plugs are designed for use in the US. Outlets and voltage differ internationally and this product may require an adapter or converter for use in your destination. Please check compatibility before purchasing.
    SKU: n/a
  • UT387B Wall Scanner

    0 out of 5
    (0)

    UT387 series wall scanners are great tools designed for construction and home improvement sector. These scanners can pick up hidden objects behind walls, such as metals, live electrical wires, and wood. UT387A is designed for dry wall, but it can also effectively scan hardwood flooring, plywood, and coated wooden walls. It has two scanning modes, these are used for scanning walls of different thickness.

    SKU: n/a
  • UTG1005A Function/Arbitrary Waveform Generator

    0 out of 5
    (0)

    1. Intuitive interface design

    2. Single channel
    3. 125MS/s sampling rate, 14-bit vertical resolution
    4. Integrated analog and digital design
    5. 4.3 inches TFT LCD
    SKU: n/a