Key features

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

21,058

Out of stock

Compare

Fluke quality is always within your reach

Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B+ digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B+ offers everything you need.

Category:

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 15B+ Digital Multimeter”

There are no reviews yet.

  • YH-305D DC Power Supply

    0 out of 5
    (0)
    • Model: YH-305D
    • Compact Design
    • All Metal Construction
    • Dual LED Three Digital Tube Display
    • Current mA / A Conversion Display
    • High Stabilized Output Voltage
    • Short Circuit Protection
    • Over Loading and Current Protection
    • CE Approved

    SKU: n/a
  • YIHUA 946A-II LCD TOUCH SCREEN GLASS SEPARATING MACHINE

    0 out of 5
    (0)

    1. With PID programmable temperature control technology and the highest precision PID input program, temperature is both adjustable and stable while deviations are minimized.

    2. The heated aluminum is smooth and flat, ensuring a uniform surface temperature.

    3. This device has the following user-friendly design features:A. Celsius/Fahrenheit temperature display;B. Temperature correction feature.

    4. The double-sided internal SMT manufacturing process boasts clean craftsmanship. The signal flow is clear, and the machine is both stable and safe, further improving its performance and adaptability to various harsh environments.

    SKU: n/a
  • UT33A+ Palm Size Multimeter

    0 out of 5
    (0)

    Main features

    1. Clear LCD display

    2. Equipped with comfortable protective cover, test lead hanging slot

    3. 2m drop proof with precision protection

    4. Auto power off

    5. Auto backlight off

    6. Loud buzzer

    7. Ergonomically designed rotary switch

    SKU: n/a
  • UT216C 600A True RMS Digital Clamp Meters

    0 out of 5
    (0)

    UT216 series true RMS digital clamp meter is a new-generation practical electrotechnical measurement meter which has the features of high reliability, high safety, automatic range and handheld type, has full-range overload protection and unique appearance design, is more excellent in performance, and is an ideal tool for detection, maintenance and repair of various universities and colleges, smelting, communication, manufacturing, petroleum, national defense, electrical, power and circuit equipment.
    UTD216C (main features)

    • 1、600A AC and DC current measurement
    • 2、True RMS response for ACV and ACA
    • 3、Inrush current function for AC current measurement
    • 4、V.F.C function for measuring signal at variable frequency
    • 5、Non-contact voltage detection with LED indication
    • 6、Flashlight for working at dark environment
    • 7、Other functions include Capacitance, Frequency and Temperature measurements
    SKU: n/a
  • CLAMP METER AC DC VC 903

    0 out of 5
    (0)

    Product Details

    You can get measurements for :

    AC/DC VOLTAGE,
    AC/DC CURRENT
    RESISTANCE
    CAPACITANCE
    FREQUENCY
    DUTY CYCLE
    CONTINUITY
    DIODE
    TEMPERATURE
    EXTRA FUNCTIONS:
    TRUE-RMS
    HOLD
    BACKLIGHT
    LOW BATTERY ALERT
    AUTO POWER OFF