MIC-2501,2500V Insulation Resistance Meter

Availability:

1 in stock


 

Electrical safety:

  • type of insulation: double, in acc. with EN 61010-1 und IEC 61557
  • measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
  • case protection rating in acc. with EN 60529: IP65

Other technical specifications:

  • power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
  • weight of the meter: approx. 0,9 kg
  • dimensions: 200 x 180 x 77 mm
  • display: LCD segment display
  • measurement results memory: 990 cells, 11880 records,
  • transmission of measurement results: USB

0

1 in stock

Compare
  • Insulation resistance measurement:
    • selectable measurement voltage in the 100…2500 V range with 100 V step,
    • continuous indication of insulation resistance or leakage current,
    • automatic discharge of capacitance of tested object after the insulation resistance measurement,
    • acoustic signalling of five-second periods to facilitate obtaining time characteristics,
    • measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s,
    • indication of actual test voltage during the measurement,
    • protection against measuring live objects,
    • two and three-lead measurement method,
  • Continuity measurement of protective and equipotential conductors according to EN 61557-4
  • with the >200 mA current.
  • Leakage current measurement.
  • Measurement of alternating and direct voltages in the 0…750 V range.
  • Built-in rechargeable battery pack.
  • The instruments meet the requirements of the EN 61557 standard.
  • The ability to charge from car lighter (12 V) socket (additional accessories).
Category:
Weight 0.9 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557-2 for RISOmin=UISOnom/IISOmax…1 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0,0…999,9 kΩ 0,1 kΩ ±(3% m.v. + 20 digits)
1,000…9,999 MΩ 0,001 MΩ ±(3% m.v. + 20 digits)
10,00…99,99 MΩ 0,01 MΩ ±(3% m.v. + 20 digits)
100,0…999,9 MΩ 0,1 MΩ ±(3% m.v. + 20 digits)
1,000…9,999 GΩ 0,001 GΩ ±(3% m.v. + 20 digits)
10,00…99,99 GΩ 0,01 GΩ ±(3% m.v. + 20 digits)
100,0…999,9 GΩ 0,1 GΩ ±(3% m.v. + 20 digits)

Values of measured resistance depending on measurement voltage

 

Voltage UISO Measurement range
100 V 50 GΩ
200…400 V 100 GΩ
500…900 V 250 GΩ
1000…2400 V 500 GΩ
2500 V 1000 GΩ

Continuity measurement of protective connections and equipotential bonding with 200 mA current.
Measurement range acc. to EN 61557-4: 0,10…999 Ω

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω ±(2% m.v. + 3 digits)
200…999 Ω 1 Ω ±(4% m.v. + 3 digits)
  • Voltage on open terminals: 4…24 V
  • Output current at R <2 Ω: ISC >200 mA
  • Compensation of test lead resistance
  • Current flowing in both directions, mean value of resistance is displayed

DC and AC voltage measurement

Range Resolution Accuracy
0…299,9 V 0,1 V ±(3% m.v. + 2 digits)
300…750 V 1 V ±(3% m.v. + 2 digits)
  • Frequency range: 45…65 Hz

The acronym “m.v.” stands for a “measured reference value”.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-2501,2500V Insulation Resistance Meter”

There are no reviews yet.

  • JM-6092B Home CR-V Rechargeable Screwdriver Set Supplier

    0 out of 5
    (0)

    Features:

    • Portable box with transparent cover.
    • Adjustable screwdriver bits.
    • Non-slip handle is made of PP & TPR material.
    • H4*60 mm magnetic extension bar.
    SKU: n/a
  • UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a