Electrical safety:

  • type of insulation: double, in acc. with EN 61010-1 und IEC 61557
  • measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
  • case protection rating in acc. with EN 60529: IP65

Other technical specifications:

  • power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
  • weight of the meter: approx. 0,9 kg
  • dimensions: 200 x 180 x 77 mm
  • display: LCD segment display
  • measurement results memory: 990 cells, 11880 records,
  • transmission of measurement results: USB

0

1 in stock

Compare
  • Insulation resistance measurement:
    • selectable measurement voltage in the 100…2500 V range with 100 V step,
    • continuous indication of insulation resistance or leakage current,
    • automatic discharge of capacitance of tested object after the insulation resistance measurement,
    • acoustic signalling of five-second periods to facilitate obtaining time characteristics,
    • measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s,
    • indication of actual test voltage during the measurement,
    • protection against measuring live objects,
    • two and three-lead measurement method,
  • Continuity measurement of protective and equipotential conductors according to EN 61557-4
  • with the >200 mA current.
  • Leakage current measurement.
  • Measurement of alternating and direct voltages in the 0…750 V range.
  • Built-in rechargeable battery pack.
  • The instruments meet the requirements of the EN 61557 standard.
  • The ability to charge from car lighter (12 V) socket (additional accessories).
Category:
Weight 0.9 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557-2 for RISOmin=UISOnom/IISOmax…1 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0,0…999,9 kΩ 0,1 kΩ ±(3% m.v. + 20 digits)
1,000…9,999 MΩ 0,001 MΩ ±(3% m.v. + 20 digits)
10,00…99,99 MΩ 0,01 MΩ ±(3% m.v. + 20 digits)
100,0…999,9 MΩ 0,1 MΩ ±(3% m.v. + 20 digits)
1,000…9,999 GΩ 0,001 GΩ ±(3% m.v. + 20 digits)
10,00…99,99 GΩ 0,01 GΩ ±(3% m.v. + 20 digits)
100,0…999,9 GΩ 0,1 GΩ ±(3% m.v. + 20 digits)

Values of measured resistance depending on measurement voltage

 

Voltage UISO Measurement range
100 V 50 GΩ
200…400 V 100 GΩ
500…900 V 250 GΩ
1000…2400 V 500 GΩ
2500 V 1000 GΩ

Continuity measurement of protective connections and equipotential bonding with 200 mA current.
Measurement range acc. to EN 61557-4: 0,10…999 Ω

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω ±(2% m.v. + 3 digits)
200…999 Ω 1 Ω ±(4% m.v. + 3 digits)
  • Voltage on open terminals: 4…24 V
  • Output current at R <2 Ω: ISC >200 mA
  • Compensation of test lead resistance
  • Current flowing in both directions, mean value of resistance is displayed

DC and AC voltage measurement

Range Resolution Accuracy
0…299,9 V 0,1 V ±(3% m.v. + 2 digits)
300…750 V 1 V ±(3% m.v. + 2 digits)
  • Frequency range: 45…65 Hz

The acronym “m.v.” stands for a “measured reference value”.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-2501,2500V Insulation Resistance Meter”

There are no reviews yet.

  • UT219DS ACA DCA Professional Clamp Meters with Motor LPF Test

    0 out of 5
    (0)
    • UT-219 professional clamp meter series is three-proofing digital clamp meter specially designed for professional industrial users.
    • The industrial design of this series is rugged and durable, and capable of withstanding the impact from 2 meters fall-down.
    • The waterproof rating is up to IP54; therefore, it can be used in environment with water splashing or much more dust.
    • The whole series is configured with LoZ (Low Impedance Input) AC voltage tap position, which is capable of testing the false voltage; auto backlight function can be used continuously under the circumstance of emergency power outage.
    • UT-219DS is also provided with MOTOR test function, allowing to directly test the phase sequence of three phase AC motor by means of the probe. UT-219 series is much more in compliance with CAT IV 600V safety level, and certified by the German GS institution.
    SKU: n/a
  • YH Q208I PIPE FOR YH 8509,

    0 out of 5
    (0)
    SKU: n/a
  • UTD2102CEX-II Digital Storage Oscilloscope

    0 out of 5
    (0)

    1. 2 channels

    2. 70MHz/100MHz bandwidth; 1GSa/s real-time sampling rate
    3. Up to 28Mpts memory depth
    4. Calibration signal output: 10Hz, 100Hz, 1kHz (by default),
    10kHz or 100kHz
    5. Max 10Mpts waveform record
    6. 8-inch TFT LCD, WVGA (800X480)
    SKU: n/a
  • UT207B 1000A True RMS Digital Clamp Meter

    0 out of 5
    (0)

    1. Flashlight button: Short press thisbutton to turn on/off the flashlight.
    2. Flexible current probe (optional) to extendthe AC current measurement range to3000A
    3. Inrush current capture
    4. NCV Multi-Segment Display and audio/visual alarm
    5. True RMS/Auto backlight
    6. NCV/Function retention

    SKU: n/a
  • CLAMP METER AC DC VC 903

    0 out of 5
    (0)

    Product Details

    You can get measurements for :

    AC/DC VOLTAGE,
    AC/DC CURRENT
    RESISTANCE
    CAPACITANCE
    FREQUENCY
    DUTY CYCLE
    CONTINUITY
    DIODE
    TEMPERATURE
    EXTRA FUNCTIONS:
    TRUE-RMS
    HOLD
    BACKLIGHT
    LOW BATTERY ALERT
    AUTO POWER OFF

    SKU: n/a
  • UT387C Wall Scanners

    0 out of 5
    (0)

    Features of UT387C/UT387D Wall Scanners

    Certificates: CE, UKCA, FCC

    ● Buzzer indication

    ● Auto power off

    ● Error calibration alarm

    ● LED alarm

    ● Low battery indication

    SKU: n/a