MRU-30 Earth Resistance and Resistivity Meter

Availability:

3 in stock


 

  • It allows to take the measurements of:

    • earthing resistance using auxiliary electrodes,
    • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
    • earthing resistance using double clamps for measuring multiple earthing without underground connections.
    • ground resistivity (Wenner method),
    • continuity of equipotential bondings and protective
    • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

    Additionally:

    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network
    • with frequency 50Hz, 60Hz,
    • selection of maximum measuring voltage (25V and 50V),
    • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
    • memory of 990 measurements (10 banks of 99 cells each),
    • calibration of clamp used,
    • data transmission to the computer (USB),
    • indication of battery state.

0

3 in stock

Compare

The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3-pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can’t be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages.

  • Robust and weatherproof (IP65) – no ingress of dust, water protected by a nozzle against enclosure from any direction.
  • Ergonomic casing – small and handy casing to make the measurements more convenient than before.
  • Built-in rechargeable battery – saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket!
  • Clear on-screen notes – displayed on screen before and after the measurement to alert user of possible dangers and irregularities.
  • Many measurement methods available in a small, portable casing
Weight 5 kg
Dimensions 20 × 15 × 7 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of continuity of equipotential bondings and protective conductors (Rcont)
measurement range to IEC 61557-4:2007: 0,13 Ω…1999 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…1999 Ω 1 Ω

• measurement current: under short circuit >200mA
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)

Measurement of earthing resistance (method 3- and 4-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (dla 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable 25 V AC or 50 V AC,
• frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz).

Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• voltage on open terminals: selectable 25 V AC or 50 V AC,
• measurement current: under short circuit >20 mA,
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)
Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% m.v.+ 8 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…19,9 kΩ 0,1 kΩ

 

Measurement of multiple earthing resistance with using double clamps

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits)
20,0…99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits)

• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz
(for networks 60 Hz)

Measurement of ground resistivity 
Measurement method: Wenner, ρ=2πLRE

Range Resolution Accuracy
0,00…9,99 Ωm 0,01 Ωm depending on measurement
accuracy RE with 4p method,
but not less than ±1 digit
10,0…99,9 Ωm 0,1 Ωm
100…999 Ωm 1 Ωm
1,00…9,99 kΩm 0,01 kΩm
10,0…99,9 kΩm 0,1 kΩm
100…999 kΩm 1 kΩm

L – distance between probes: 1…50 m.. or 1…150 ft

Electric security:

  • type of insulation: double, according to EN 61010-1 i IEC 61557,
  • measurement category: CAT III 300V wg EN 61010-1,
  • protection class acc. to EN 60529: IP65,

Rated operational conditions:

  • operation temperature: -10…+55°C,
  • storage temperature: -20…+80°C,
  • humidity: 20…90%,

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 200x150x74 mm.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-30 Earth Resistance and Resistivity Meter”

There are no reviews yet.

  • 40W Soldering Iron Soldering Tool

    0 out of 5
    (0)

    soldering iron is a hand tool used to heat solder, usually from an electrical supply at high temperatures above the melting point of the metal alloy. This allows for the solder to flow between the workpieces needing to be joined.

    SKU: n/a
  • JM-8102 Family And Household Screwdriver Set

    0 out of 5
    (0)

     

    Features:

    • Finest CR-V bits with HRC up to 52
    • Adjustable screwdriver bits for different scews.
    • Common uesd in precision work in electronics, DIY models, jewerlry, eye glasses and other home appliances.
    • Portable box with transparent cover.
    SKU: n/a
  • UT 205A+

    0 out of 5
    (0)
    1. 1000A AC current measurement
    2. 1000V AC/DC voltage measurement
    3. 600A inrush current measurement (UT206A+)
    4. Temperature  (UT206A+)
    5. NCV (UT206A+)
    6. ACV frequency 10Hz~10kHz
    7. Jaw opening: 45mm
    8. Resistance / capacitance / frequency measurement
    9. Auto range / backlight / low battery indication
    10. Continuity / diode / duty cycle
    11. MAX/MIN
    12. Data hold / flashlight / relative mode
    13. Auto power off
    14. CAT II 1000V/CAT III 600V
    SKU: n/a
  • UNI-T UTi320V Thermal Image

    0 out of 5
    (0)

    Technical Specifications of UTi320V Thermal Image:

    Specifications
    Model UTi320V
    Temperature range  -20~350℃
     -4℉~662℉
    Temperature accuracy ±2℃ or ±2% (whichever is greater)
    Temperature resolution 0.1℃/0.18℉
    Thermal resolution 320×240
    Temperature coefficient ± 0.1/℃ or ± 0.1%/℃ (whichever is greater)
    Visible light resolution 640×480
    Emissivity Adjustable (0.01-1.00), 0.98 in default
    Reflectivity Reflectivity correction (adjustable background temperature)
    Palettes White hot, iron red, arctic, rainbow 2, hot iron, rainbow 1
    High/low temperature tracking
    High/low temperature alarm
    Image blending/Picture in picture
    WIFI mode Connects to PC software and moblie phone App
    Lens 7mm
    Focus Focus free
    FOV 42.5°×32.5°
    NETD ≤60mK
    Image frequency 50Hz
    Digital zoom ×2, ×4
    General Characteristics
    Power 7.4V 2300mAh Li-ion battery
    Display 3.5-inches TFT LCD
    Product color Red and grey
    Product net weight 1.8kg (Package)
    Product size 258mm x 98mm x 90mm
    Standard accessories Li-on battery x 2, USB power supply with multi plugs,
    wrist strap, adaptor×5, SD card, USB cable, PC software CD
    Standard individual packing Gift box, tool box, English manual
    Standard quantity per carton 1pcs
    Standard carton measurement 410mm x 265mm x 180mm
    Standard carton gross weight 2.2kg
    SKU: n/a
  • TND 2000VA

    0 out of 5
    (0)

    Input Voltage=140-250
    Output Voltage=220
    Copper Wind
    Analog Display
    Under and Over Volt Indication
    Under Volt Protection
    Dual Output Socket 110/220

    SKU: n/a