-5%

UT714 Multifunction Temperature Process Calibrator


The UT714 is powerful temperature calibrator that sources and measures thermocouples, RTDs, voltage, and resistance. It can be used to test and calibrate diffrent types of temperature instruments. This device is suitable for testing input/output temperature terminals such as sensors and transmitters.

180,400 190,000

Compare

The UT714 is powerful temperature calibrator that sources and measures thermocouples, RTDs, voltage, and resistance. It can be used to test and calibrate diffrent types of temperature instruments. This device is suitable for testing input/output temperature terminals such as sensors and transmitters.

Specifications of UT714 Multifunction Temperature Process Calibrator

Specifications Range UT714
Measurement
DC voltage (V) 50mV/500mV/30V ±(0.02%+2)
Resistance (Ω) 500Ω/5000Ω ±(0.05%+10)
Thermocouples R,S,K,E,J,T,N,B,L,U
RTDs Pt100/Pt200/Pt500/Pt1000/Cu10/Cu50/Cu100/Pt100-392/Pt100-JIS/Ni120
Continuity test
Source
DC voltage (V) 100mV/1000mV/10V ±(0.02%+10)
Resistance (Ω) 400Ω/4000Ω ±(0.05%+10)
Thermocouples R,S,K,E,J,T,N,B,L,U
RTDs Pt100-385/Pt100-392/Pt100-JIS/Pt200-385/P500-385/Pt1000-385/Cu10/Cu50/Cu100/Ni120
Display count 20000
Operating temperature  -10°C~55°C
General Characteristics
Power 1.2V x 6 AA rechargeable battery
Product net weight 650g
Product size 195mm x 95mm x 58mm
Standard accessory Test lead, USB cable, power adapter, temperature probe, English manual

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT714 Multifunction Temperature Process Calibrator”

There are no reviews yet.

  • TKF-12 Phase Sequence Tester

    0 out of 5
    (0)

    Phase sequence indication (direction of field rotation) in the power network with rated phase-to-phase voltage (120…690 V) AC by LED signalization.
    Operation in the power network with frequency range 10…70 Hz.

    Indication of the voltage presence in the particular phases by neon lamps signalization.
    Power supply from the tested network (continuous operation to 15 minutes for max. voltage).
    Protection against faulty indication of field rotation.

    SKU: n/a
  • UT601 Inductance Capacitance Meters

    0 out of 5
    (0)

    UT600 series RCL meter is a kind of 3.5-bithandheld digital meter with stable performance, safety, reliability, highaccuracy and manual range. It can be used to measure the magnification times β of audion, diode forward voltage drop and circuit continuity. UT601has wide capacitance measurement range from 0.1pF~20mF and highaccuracy. UT602 can hold data. UT 600 series is applicable to testingresistance, capacitance and inductance of electronic laboratory, productionline, maintenance point and teaching. It is the ideal tool of maintaining formany users

    SKU: n/a
  • JM CT-2-2 5″ CUTTER

    0 out of 5
    (0)
    SKU: n/a