1. Auto range
2. Auto polarity indication
3. Relative mode
4. Data hold
5. Auto power off Function
6. Capacitance measurement
7. Complies with CE (European Union) directives
20 in stock
Main Features
1. Auto range
2. Auto polarity indication
3. Relative mode
4. Data hold
5. Auto power off Function
6. Capacitance measurement
7. Complies with CE (European Union) directives
₨3,960 ₨4,015
20 in stock
Compare1. Auto range
2. Auto polarity indication
3. Relative mode
4. Data hold
5. Auto power off Function
6. Capacitance measurement
7. Complies with CE (European Union) directives
Weight | 0.1 kg |
---|---|
Dimensions | 11 × 6 × 11 cm |
Specifications | Range | Best Accuracy |
Model | UT120A | |
DC Voltage (V) | 4V/40V/400V/600V | ±(0.8%+3) |
AC Voltage (V) | 4V/40V/400V/600V | ±(1.2%+3) |
Resistance (Ω) | 400Ω/4KΩ/40KΩ/400KΩ/4MΩ/40MΩ | ±(1%+2) |
Frequency (Hz) | 99.99Hz~99.99KHz | ±(0.5%+3) |
Features | ||
Display Count | 4000 | |
Auto Range | √ | |
Duty Cycle | 0.1%~99.9% | √ |
Diode | √ | |
Auto Power Off | Around 30 Minutes | √ |
Continuity Buzzer | √ | |
Low Battery Indication | ≤2.4V | √ |
Data Hold | √ | |
Relative Mode | √ | |
Input Impedance for DCV | Around 10MΩ | √ |
General Characteristic | ||
Power | 3V Battery(CR2032) | |
LCD Size | 43mm X 22mm | |
Product Color | Red and Grey | |
Product Net Weight | 76g | |
Product Size | 110mm X 58.2mm X 10.8mm | |
Standard Accessories | Battery,Carrying Case | |
Standard Individual Packing | Blister, English Manual | |
Standard Quantity Per Carton | 90 PCs | |
Standard Carton Measurement | 528mm X 323mm X 400mm (0.068 CBM Per Export Carton) | |
Standard Carton Gross Weight | 13.5 Kg |
This model has compact design with all metal construction.
1.This unit now features a Dual LED display with highly accurate LED digital readout.
2.Maximum output is 30V at 10A.
5.Over loading and current protection.
Analog bandwidth | 150MHz | 250MHz | ||
Channels | 2+16 digital | 4+16 digital | 2+16 digital | 4+ 16digital |
Sampling rate (Analog) | 2.5GS/s (Single channel), 1.25GS/s (Dual channels) | |||
Sampling rate (Digital) | 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) | |||
Memory depth | 70Mpts | |||
Waveform capture rate | 200,000wfms/s | |||
Time base scale | 2ns/div~50s/div (Real-time sampling rate, memory depth display ) | |||
Time base scale (digital) | 2ns/div~40S/div[Step by 1-2-4 stall] | |||
Input impedance | (1MΩ±1%) II (20pF±3pF) | |||
Input impedance digital | (101kΩ±1%) II (9pF±1pF) | |||
Vertical scale | 1mV/div~20 V/div (1 MΩ) | |||
DC gain accuracy | <5mV: ±3%, ≥5mV: ±2% | |||
Waveform record | 100,000 frames | |||
Trigger types | Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay |
|||
Bus decode | RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay | |||
Waveform operations | A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations | |||
Auto measurements |
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width, -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A |
|||
Measurement display | 5 types | |||
Measurement statistics | Average, Max, Min, standard deviation and number of measurements | |||
Frequency counter | 6 bits | |||
Standard interfaces | USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA | |||
Standard Accessories |
USB interface cable | UT-D14 | ||
Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) | UT-P06 | |||
Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) | UT-P05 | |||
16CH Logic analyzer probe | UT-15M |
Features
. Digital clamp meter 266 opens 52mm.
2. Large LCD display makes reading clear.
3. Full function protection, strong anti-interferential performance.
4. CE standard design, improves the safety of the test.
5. Data hold.
6. Clamp light and backlight display.
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
There are no reviews yet.