-28%

UT501A Insulation Resistance Tester

Availability:

5 in stock


1. 2000 count LCD display, overload indication, backlight

2. AC voltage measurement, auto power off
3. Auto discharge
4. Continuous measurements mode, red warning light and buzzer function

15,000 20,710

5 in stock

Compare
UT500 series insulation testers are used to measure the insulation resistance of electrical  equipment and household appliances. This is done by measuring the insulation resistance between electrical circuits or between circuits and ground. UT500 series can measure insulation resistance, AC Voltage, low resistance, PI (Polarization Index) and DAR (Dielectric Absorption). These are dieal  tools for ensuring transformers, genera-tors, high voltage motors, power capacitors, power cbles, arresters and other electrical equipment that can oprate in a safe and accurate manner.
Applications:
It is used for insulation resistance measurement for insulation materials and various kinds of electric equipments such as transformer, electric machines, cables, switches, electrical appliance, a ideal tool for electric maintenance, testing and inspection.
Category:
Weight 0.5 kg
Dimensions 15 × 10 × 7 cm
Specifications Range UT501A
Insulation resistance (Ω) Test voltages 100V/250V/500V/1000V 0%~10%
100V 0MΩ~100MΩ ±(3%+5)
250V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~5GΩ ±(5%+5)
500V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~5GΩ ±(5%+5)
1000V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~5GΩ ±(5%+5)
Load current 50V (R=50kΩ) 1mA 0%~10%
100V (R=100kΩ) 1mA 0%~10%
250V (R=250kΩ) 1mA 0%~10%
500V (R=500kΩ) 1mA 0%~10%
1000V (R=1MΩ) 1mA 0%~10%
Short-circuit current <2mA
AC voltage (V) 30V~750V ±(2%+3)
Features
Display count 2000
Auto range/Low battery indication
LCD backlight/Light alarm
Buzzer alarm/High voltage indication
Over load indication/Auto discharge
Test voltage secondary display
10MΩ internal resistance test
General Characterisitics
Power 1.5V battery (LR6) x 6
Display 70.6mm x 34mm
Product color Red and grey
Product net weight 500g
Product size 150mm x 100mm x 71mm
Standard accessories Batteries, test leads, alligator clips, gallus
Standard individual packing Gift box, carrying bag, English manual
Standard quantity per carton 20pcs
Standard carton measurement 500mm x 380mm x 330mm (0.063 CBM per standard carton)
Standard carton gross weight 17.7kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT501A Insulation Resistance Tester”

There are no reviews yet.

  • Fluke 15B+ Digital Multimeter

    0 out of 5
    (0)

    Key features

    • 600 V Cat III safety rating
    • 50% bigger display with bright white backlight
    • Voltage, resistance, continuity, capacitance
    • Input terminal for ac and dc current measurements to 10 A current
    • Diode test, data hold
    SKU: n/a
  • ANALOG METER YX 960 TR

    0 out of 5
    (0)

    Features Of YX-960 TR Handheld Analog Multimeter:

    • Excellent DC resolution factor of 2mV.
    • Expanded resistance measurement from 020 to 200M.
    • Series capacitor DC to enable measurement of only AC components.
    • A large and bright meteor with a scale length of 80mm.
    • The sensitivity of 44pA at full scale.
    • Fuse and diode protection.
    • Measures hFE of transistor directly.
    SKU: n/a
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a
  • LM60 Laser Distance Meter

    0 out of 5
    (0)

    1. Ergonomic exterior, comfortable handling

    2. Millimeter accuracy
    3. Large, multiple angle HD display
    5. Physical and electronics leveler
    6. Multiple functions: Max/Min/continuous measurement, displacement calculation, data storage, and more
    7. Auto power off after 3 minutes without operation
    SKU: n/a