The BT-100D 100+ Amp Digital Battery Load Tester is microprocessor controlled. It makes for an easy and accurate load test with no need to time yourself to get accurate results. Bright, LED Digital Display indicates both voltage and test results. A unique 3-Step Design provides LED polarity check function, battery load test and charging system test readout. Automatically Turns Off the Load after 10 seconds and locks the voltage. Super-Grip Battery Clamps are heavy-duty and color-coded. Baked Enamel, Steel Case to keep cool. Rubber Insulated Carrying Handle–for comfort and safety. Checks both Battery and Charging System.
Battery Load Tester – BT 100D
7 in stock
- 100 Amp Digital Battery Load Tester
- Microprocessor Control–makes for an easy and accurate load test with no need to time yourself
- Bright, LED Digital Display–indicates both voltage and test results
- Unique 3-Step Design–LED polarity check function, battery load test and charging system test readout
- Super-Grip Battery Clamps–heavy-duty and color-coded
- Baked Enamel, Steel Case–ventilated to keep cool
- Rubber Insulated Carrying Handle–for comfort and safety
- Checks both Battery and Charging System
₨5,000 ₨7,000
7 in stock
CompareWeight | 0.7 kg |
---|---|
Dimensions | 15 × 8 × 6 cm |
12 Volt Battery Analysis
Press “START TEST” & wait for 10 seconds.
Once automatic test cycle is completed, your test results will be:
1. GREEN LIGHT = OK):
Battery capacity is good. May or may not be fully charged.
Determine state of charge by checking specific gravity (use hydrometer). If gravity is less than full charge, check for possible charging system trouble or electrical drain. Recharge battery to fully charged level.
2. GREEN + YELLOW LIGHT = OK BUT WEAK):
Review the load test result with the comparison chart on the tester cover to see if this battery is “OK” or not. If it is “OK”, go up to 1ST “OK” state. If it is not, go down to 3rd “WEAK” state.
3. YELLOW LIGHT = WEAK):
Battery capacity is unsatisfactory. Battery may be either: (1) defective or (2) partially discharged. To determine which, check specific gravity. If gravity is over 1.225, battery is considered defective. If gravity is under 1.225, recharge battery and re-test. If cell-to-cell gravity varies more than 0.025 (25 points), cell trouble may exist. If charging does not bring gravity to fully charged level, the battery is either sulfated or has lost active material.
4. RED LIGHT = BAD):
Battery may be defective (e.g. a bad cell).
NOTE: If pre-test battery voltage is below 12.3V, tester will not allow and should not perform the load test. Please fully charge battery and retest.
Based on 0 reviews
Be the first to review “Battery Load Tester – BT 100D”
-
Wire & Cable Testers
LKZ-1000 Wires and pipe locator
- Passive or active modes of tracing.
- Detection of underground live wires.
- Detection of underground wires with no voltage (radio mode).
- Detection of underground wires with no voltage using a transmitter (galvanised, inductive or clamp-based connection).
- Tracing metallic or non-conductive pipes using an additional probe.
- Tracing non-conductive pipelines using a “floating” probe.
- Tracing a determined cable.
- Determining the depth of a cable.
SKU: n/a -
Laser Distance Meters
LM100 Laser Distance Meter
1. Ergonomic exterior, comfortable handling
2. Millimeter accuracy3. Large, multiple angle HD display5. Physical and electronics leveler6. Multiple functions: Max/Min/continuous measurement, displacement calculation, data storage, and more7. Auto power off after 3 minutes without operationSKU: n/a -
LCR Meter
UT622A Digital Inductance LCR Meter
Specifications UT622A UT622C UT622E Certificates CE, RoHS Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz Test signal level 0.1Vrms, 0.3Vrms, 1Vrms Output impedance 100Ω Measurement parameters Primary: L/C/R/Z
Secondary: D/Q/θ/ESRPrimary: L/C/R/Z/DCR Secondary: D/Q/θ/ESR Auto LCR √ Test terminals Three-terminal test jacks, five-terminal test sockets Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s) DCR test rate — — Fast (20 times/s), medium (5 times/s), or slow (2 times/s) Ranging mode Auto/hold Tolerance range 1%~20% Testing circuit mode Series/parallel mode Clearing correction Open/short circuit Fuse of test ports 0.1A/250V Communication interface Mini-USB LED alarm for tolerance
(pass: green; fail: red)√ √ √ Display range Maximum reading 99999 Minimum resolution 0.0001 Maximum accuracy 0.001 L 0.00μH~99.999H C 0.00pF~99.999mF Z/R 0.0000Ω~9.9999MΩ ESR 0.0000Ω~999.99Ω D 0.0000~9.9999 Q 0.0000~99999 θ -179.9°~179.9° DCR — — 0.01mΩ–20.000MΩ Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C) General Characteristics Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A Display 2.8′ TFT LCD 320X240 Product net weight 420g Product size 93mm x 192mm x 44mm Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual SKU: n/a
There are no reviews yet.